Prevention of capsular bag opacification with a modified hydrophilic acrylic disk-shaped intraocular lens

被引:35
|
作者
Leishman, Lisa [1 ]
Werner, Liliana [1 ]
Bodnar, Zachary [1 ]
Ollerton, Andrew [1 ]
Michelson, Jennifer [1 ]
Schmutz, Mason [1 ]
Mamalis, Nick [1 ]
机构
[1] Univ Utah, John A Moran Eye Ctr, Dept Ophthalmol & Visual Sci, Salt Lake City, UT 84132 USA
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2012年 / 38卷 / 09期
关键词
EPITHELIAL-CELL PROLIFERATION; AQUEOUS-HUMOR; RABBIT EYES; EQUATOR RINGS; SPRING ACTION; IMPLANTATION; EFFICACY; INTERLEUKIN-1; TGF-BETA-2; DESIGN;
D O I
10.1016/j.jcrs.2012.04.040
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the stability and capsular bag opacification with a modified disk-shaped 1-piece hydrophilic acrylic intraocular lens (IOL) suspended between 2 complete haptic rings connected by a pillar of the haptic material and with a commercially available 1-piece hydrophilic acrylic IOL. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. DESIGN: Experimental study. METHODS: Study and control IOLs were implanted into the left eyes and right eyes of 5 New Zealand rabbits. Eyes were examined at the slitlamp from 1 through 4 weeks. At 4 weeks, the globes were enucleated and evaluated under a very-high-frequency ultrasound. Photographs were taken and capsular bag opacification scored from the posterior aspect (Miyake-Apple view), and the eyes were processed for complete histopathology. RESULTS: At 4 weeks, the posterior capsule opacification score was 0.0 in the study group and 1.75 +/- 0.5 (SD) in the control group (P=.005, paired t test). Ultrasound examination showed that 2 of the study IOLs had no contact between the posterior optic surface and the posterior capsule. Minimal proliferative cortical material was confined to the peripheral space between anterior and posterior rings of the study IOL haptics in localized areas at the equatorial region of the capsular bag. Anterior capsule opacification was absent in all eyes. CONCLUSIONS: The study IOL is a modification of a previous design, incorporating haptic perforations between the peripheral rings. By maintaining an open capsular bag and enhancing endocapsular inflow of aqueous, this modified design appears to prevent capsular bag opacification.
引用
收藏
页码:1664 / 1670
页数:7
相关论文
共 50 条
  • [41] Effect of in-the-bag intraocular lens fixation on the prevention of posterior capsule opacification
    Ram, J
    Pandey, SK
    Apple, DJ
    Werner, L
    Brar, GS
    Singh, R
    Chaudhary, KP
    Gupta, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (07): : 1039 - 1046
  • [42] Misdiagnosis of hydrophilic acrylic intraocular lens optic opacification - Report of 8 cases with the MemoryLens
    Haymore, Jonathan
    Zaidman, Gerald
    Werner, Litiana
    Mamalis, Nick
    Hamilton, Stephan
    Cook, James
    Gillette, Thomas
    OPHTHALMOLOGY, 2007, 114 (09) : 1689 - 1695
  • [43] IMPLANTATION OF A DISK LENS IN THE CAPSULAR BAG
    WATTS, MT
    PEARCE, JL
    OPHTHALMIC SURGERY AND LASERS, 1988, 19 (08): : 546 - 548
  • [44] Capsular bag opacification after experimental implantation of a new accommodating intraocular lens in rabbit eyes
    Werner, L
    Pandey, SK
    Izak, AM
    Vargas, LG
    Trivedi, RH
    Apple, DJ
    Mamalis, N
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (05): : 1114 - 1123
  • [45] Reversible opacification of a hydrophobic acrylic intraocular lens
    Quigley, Clare
    Ashraf, Muhammad Omar
    Manning, Sonia
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (02): : 319 - 319
  • [46] Misdiagnosed opacification of a hydrophobic acrylic intraocular lens
    Ahmed, Syed Naqib
    Shahid, Syed Mohammed
    Nanavaty, Mayank A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1512 - 1514
  • [47] Late postoperative opacification of hydrophilic acrylic intraocular lenses
    Oner, HF
    Durak, I
    Saatci, OA
    OPHTHALMIC SURGERY AND LASERS, 2002, 33 (04): : 304 - 308
  • [48] Effect of Hydrophobic Acrylic versus Hydrophilic Acrylic Intraocular Lens on Posterior Capsule Opacification: Meta-Analysis
    Li, Ying
    Wang, Jiaxing
    Chen, Zhuo
    Tang, Xin
    PLOS ONE, 2013, 8 (11):
  • [49] Capsular tension ring alone and associated with acrylic foldable intraocular lens in posterior capsular opacification after phacoemulsification in dogs
    Morales, Adriana
    da Costa, Paula Ferreira
    da Conceicao, Luciano Fernandes
    de Andrade, Alexandre Lima
    Martinez Padua, Ivan Ricardo
    Marinho, Fabio Andrade
    da Cunha Brito, Fabio Luiz
    Lausi, Jose Luiz
    CIENCIA RURAL, 2015, 45 (03): : 540 - 545
  • [50] Posterior capsular calcification without opacification of intraocular lens
    Joshi, R. S.
    NEPALESE JOURNAL OF OPHTHALMOLOGY, 2016, 8 (01) : 91 - 94