Effect of Hydrophobic Acrylic versus Hydrophilic Acrylic Intraocular Lens on Posterior Capsule Opacification: Meta-Analysis

被引:37
|
作者
Li, Ying [1 ]
Wang, Jiaxing [2 ]
Chen, Zhuo [1 ]
Tang, Xin [1 ]
机构
[1] Tianjin Med Univ, Tianjin Eye Hosp, Clin Coll Ophthalmol, Tianjin, Peoples R China
[2] Tianjin Med Univ, Gen Hosp, Dept Ophthalmol, Tianjin, Peoples R China
来源
PLOS ONE | 2013年 / 8卷 / 11期
关键词
OPTIC EDGE DESIGN; 2-YEAR FOLLOW-UP; IMPLANTATION; SILICONE; ACRYSOF; RATES; EYES; CATARACT; HYDROGEL; INHIBITION;
D O I
10.1371/journal.pone.0077864
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: This meta-analysis aims to evaluate the differences in performance of posterior capsular opacification (PCO) between hydrophobic acrylic intraocular lens (IOLs) and hydrophilic acrylic IOLs. Setting: Tianjin Medical University, Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin, China. Design: Systematic review of randomized controlled trials (RCTs) or meta-analysis. Methods: An electronic literature search was performed using the PubMed, EMBASE and Cochrane Library database before May in 2013 to identify prospective RCTs comparing hydrophobic acrylic IOLs and hydrophilic acrylic IOLs in patients after phacoemulsification with IOL implantation with a follow-up time of at least 1 year. Pertinent studies were selected by meeting predefined criteria and reviewed systematically by meta-analysis. The PCO scores and YAG capsulotomy rate, as indicator of PCO, were measured and discussed in a meta-analysis. Standardized mean differences (SMD), relative risk ratio (RR), and the pooled estimates were computed according to a random effect model or fixed effect model. Results: Nine prospective RCTs involving 861 eyes were included in the current meta-analysis. The hydrophobic acrylic IOLs were favored and the pooled SMD of PCO severity was 1.72 (95% confidence interval (CI), 0.20 to 1.23, P = 0.0002) and 1.79 (95% CI, 0.95 to 2.64, P<0.0001) with 1-year follow-up and 2-year follow-up respectively. The pooled RR of Nd:YAG laser capsulotomy rates at postoperative 2-year follow-up was 6.96 (95% CI, 3.69 to 13.11, P<0.00001) comparing hydrophilic acrylic IOLs with hydrophobic acrylic IOLs. Conclusions: Compared with hydrophilic acrylic IOLs, the hydrophobic acrylic IOLs showed superior reduction in rates of PCO and laser capsulotomy in 2-year follow-up. More RCTs with standard methods for longer follow-up are needed to validate the association.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Hydrophobic versus hydrophilic acrylic intraocular lens on posterior capsule opacification: a Meta-analysis
    Qiong Wu
    Yan Li
    Lian Wu
    Cong-Yi Wang
    International Journal of Ophthalmology, 2022, (06) : 997 - 1004
  • [2] Hydrophobic versus hydrophilic acrylic intraocular lens on posterior capsule opacification: a Meta-analysis
    Wu, Qiong
    Li, Yan
    Wu, Lian
    Wang, Cong-Yi
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2022, 15 (06) : 997 - 1004
  • [3] Comparison of posterior capsule opacification with hydrophobic acrylic and hydrophilic acrylic intraocular lenses
    Vasavada, Abhay R.
    Raj, Shetal M.
    Shah, Alpesh
    Shah, Gauri
    Vasavada, Viraj
    Vasavada, Vaishali
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1050 - 1059
  • [4] Intraocular Lens and Capsule Opacification with Hydrophilic and Hydrophobic Acrylic Materials
    Saeed, Muhammad Usman
    Jafree, Afsar Jalil
    Saeed, Mohammad Salman
    Zia, Rashid
    Sheikh, Ijaz Mehmood
    Heravi, Mohammad
    SEMINARS IN OPHTHALMOLOGY, 2012, 27 (1-2) : 15 - 18
  • [5] Hydrophobic versus double-square-edged hydrophilic foldable acrylic intraocular lens: Effect on posterior capsule opacification
    Iwase, Takeshi
    Nishi, Yutarou
    Oveson, Brian C.
    Jo, Young-Joon
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1060 - 1068
  • [6] Opacification of a Hydrophilic Acrylic Intraocular Lens
    Yang, Yezhen
    Peng, Manqiang
    Duan, Yiqin
    Huang, Xuetao
    Li, Kuanshu
    Lin, Ding
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2017, 27 (03): : S58 - S60
  • [7] Opacification of a hydrophilic acrylic intraocular lens
    Ouederni, M.
    Nefaa, F.
    Brour, J.
    Cheour, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2018, 41 (08): : 773 - 774
  • [8] Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification
    Buehl, W
    Findl, O
    Menapace, R
    Rainer, G
    Sacu, S
    Kiss, B
    Petternel, V
    Georgopoulos, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07): : 1105 - 1111
  • [9] Secondary opacification of a hydrophilic acrylic multifocal intraocular lens with a hydrophobic surface
    Gambrelle, J.
    Robinet, A.
    Le Loir, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2015, 38 (02): : E27 - E28
  • [10] Late postoperative opacification of a hydrophilic-hydrophobic acrylic intraocular lens
    Bompastor-Ramos, Paula
    Povoa, Joao
    Lobo, Conceicao
    Rodriguez, Alejandra E.
    Alio, Jorge L.
    Werner, Liliana
    Murta, Joaquim N.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (09): : 1324 - 1331