Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles

被引:64
|
作者
Shoaie, Nahid [1 ]
Forouzandeh, Mehdi [1 ,2 ]
Omidfar, Kobra [2 ,3 ]
机构
[1] Tarbiat Modares Univ, Fac Med Sci, Dept Med Biotechnol, POB 14115-111, Tehran, Iran
[2] Tehran Univ Med, Biosensor Res Ctr, Endocrinol & Metab Mol Cellular Sci Inst, POB 1411713137, Tehran, Iran
[3] Univ Tehran Med Sci, Endocrinol & Metab Res Ctr, Endocrinol & Metab Res Inst, Tehran, Iran
关键词
Infectious diseases; Cyclic voltammetry; Screen-printed carbon electrode; Capture probe; Digoxigenin-labeled detector probe; URINARY-TRACT-INFECTIONS; ELECTROCHEMICAL BIOSENSOR; SENSITIVE DETECTION; NANOCOMPOSITE; AMPLIFICATION; DIAGNOSIS; GRAPHENE;
D O I
10.1007/s00604-018-2749-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors describe an electrochemical assay for fast detection of Escherichia coli (E. coli). It is based on a dual signal amplification strategy and the use of a screen-printed carbon electrode (SPCE) whose surface was modified with a polyaniline (PANI) film and gold nanoparticles (AuNPs) via cyclic voltammetry (CV). In the next step, avidin was covalently immobilized on the PANI/AuNP composite on the SPCE surface. Subsequently, the biotinylated DNA capture probe was immobilized onto the PANI/AuNP/avidin-modified SPCE by biotin-avidin interaction. Then, DNA of E. coli, digoxigenin-labeled DNA detector probe and anti-digoxigenin-labeled horseradish peroxidase (HRP) were placed on the electrode. 3,3',5,5'-Tetramethylbenzidine (TMB) and H2O2 solution were added and the CV electrochemical signal was generated at a potential of -0.1 V (vs. Ag/AgCl) and a scan rate 50 mV. s(-1). The assay can detect 4 x 10(6) to 4 CFU of E. coli without DNA amplification. The biosensor is highly specific over other pathogens including Klebsiella pneumoniae, Proteus mirabilis, Enterococcus faecalis, Staphylococcus haemolyticus and Pseudomonas aeruginosa. It can be concluded that this genosensor has an excellent potential for rapid and accurate diagnosis of E. coli inflicted infections.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Direct Electrochemical Determination of Glyphosate Herbicide Using a Screen-Printed Carbon Electrode Modified with Carbon Black and Niobium Nanoparticles
    Fernandes, Julia Oliveira
    Bernardino, Cassiano Augusto Rolim
    Fernandes, Juliana dos Santos
    Mahler, Claudio Fernando
    Braz, Bernardo Ferreira
    dos Santos, Luiz Henrique Carpenter
    Correa, Rodrigo Jose
    Santelli, Ricardo Erthal
    Archanjo, Braulio Soares
    Ribeiro, Emerson Schwingel
    Cincotto, Fernando Henrique
    [J]. JOURNAL OF ANALYSIS AND TESTING, 2023, 7 (04) : 425 - 434
  • [42] A screen-printed carbon electrode modified with gold nanoparticles, poly(3,4-ethylenedioxythiophene), poly(styrene sulfonate) and a molecular imprint for voltammetric determination of nitrofurantoin
    Dechtrirat, Decha
    Yingyuad, Peerada
    Prajongtat, Pongthep
    Chuenchom, Laemthong
    Sriprachuabwong, Chakrit
    Tuantranont, Adisorn
    Tang, I-Ming
    [J]. MICROCHIMICA ACTA, 2018, 185 (05)
  • [43] A screen-printed carbon electrode modified with gold nanoparticles, poly(3,4-ethylenedioxythiophene), poly(styrene sulfonate) and a molecular imprint for voltammetric determination of nitrofurantoin
    Decha Dechtrirat
    Peerada Yingyuad
    Pongthep Prajongtat
    Laemthong Chuenchom
    Chakrit Sriprachuabwong
    Adisorn Tuantranont
    I-Ming Tang
    [J]. Microchimica Acta, 2018, 185
  • [44] Determination of inorganic mercury using a polyaniline and polyaniline-methylene blue coated screen-printed carbon electrode
    Somerset, Vernon
    Leaner, Joy
    Mason, Robert
    Iwuoha, Emmanuel
    Morrin, Aoife
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2010, 90 (09) : 671 - 685
  • [45] Gold nanoparticles modified ceria nanoparticles for the oxidation of hydrazine with disposable screen-printed electrode
    Sun, Haiyi
    Zhao, Shugao
    Qu, Fengli
    [J]. MEASUREMENT, 2012, 45 (05) : 1111 - 1113
  • [46] Voltammetric determination of sulfamethoxazole using commercial screen-printed carbon electrodes
    Alberto, Elena
    Bastos-Arrieta, Julio
    Perez-Rafols, Clara
    Serrano, Nuria
    Diaz-Cruz, M. Silvia
    Diaz-Cruz, Jose Manuel
    [J]. MICROCHEMICAL JOURNAL, 2023, 193
  • [47] Flow injection amperometric determination of isoniazid using a screen-printed carbon electrode modified with silver hexacyanoferrates nanoparticles
    de Oliveira, Paulo Roberto
    Oliveira, Marcela Mohallem
    Zarbin, Aldo J. G.
    Marcolino-Junior, Luiz Humberto
    Bergamini, Marcio F.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 795 - 802
  • [48] Moxifloxacin Hydrochloride Electrochemical Detection at Gold Nanoparticles Modified Screen-Printed Electrode
    Shehata, M.
    Fekry, Amany M.
    Walcarius, Alain
    [J]. SENSORS, 2020, 20 (10)
  • [49] Selenocystine modified screen-printed electrode as an alternative sensor for the voltammetric determination of metal ions
    Puy-Llovera, Jaume
    Perez-Rafols, Clara
    Serrano, Nutiria
    Diaz-Cruz, Jose Manuel
    Arino, Cristina
    Esteban, Miguel
    [J]. TALANTA, 2017, 175 : 501 - 506
  • [50] Determination of ascorbic acid in serum samples by screen-printed carbon electrodes modified with gold nanoparticles
    Asuncion Alonso-Lomillo, M.
    Dominguez-Renedo, Olga
    Saldana-Botin, Abraham
    Julia Arcos-Martinez, M.
    [J]. TALANTA, 2017, 174 : 733 - 737