Determination of inorganic mercury using a polyaniline and polyaniline-methylene blue coated screen-printed carbon electrode

被引:28
|
作者
Somerset, Vernon [1 ]
Leaner, Joy [1 ]
Mason, Robert [2 ]
Iwuoha, Emmanuel [3 ]
Morrin, Aoife [4 ]
机构
[1] CSIR, NRE, Water Ecosyst Res Grp, ZA-7599 Stellenbosch, South Africa
[2] Univ Connecticut, Dept Marine Sci, Groton, CT 06340 USA
[3] Univ Western Cape, Dept Chem, SensorLab, ZA-7535 Bellville, South Africa
[4] Dublin City Univ, Dept Chem Sci, Sensors & Separat Grp, Dublin 9, Ireland
基金
新加坡国家研究基金会;
关键词
inorganic mercury determination; polyaniline nanoclusters; polyaniline-methylene blue nanorods; screen-printed carbon electrode (SPCE); differential pulse anodic stripping voltammetry (DPASV); STRIPPING VOLTAMMETRIC DETERMINATION; TRACE MERCURY; CAPILLARY-ELECTROPHORESIS; ION-EXCHANGE; BIOSENSOR; REMOVAL; WATER; ACID; FILM; ORGANOPHOSPHATE;
D O I
10.1080/03067310902962536
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Inorganic mercury ions (Hg(2+)) in laboratory prepared solutions were determined with a screen-printed carbon electrode (SPCE) coated with a polyaniline-methylene blue (PANI-MB) polymer layer. The structure and properties of the PANI-MB polymer layer were compared to that of normal polyaniline (PANI) in order to elucidate the structure of the PANI-MB layer. The electrically-conducting polymers were prepared by electrochemical polymerisation of monomer solutions of aniline, and mixed solutions of aniline with methylene blue onto respective screen-printed carbon electrodes (SPCEs). Scanning Electron Microscopy (SEM) analyses of the SPCE polymer coated electrodes have shown that nanostructured materials have formed with the diameters of the PANI nanoclusters and PANI-MB nanorods at approximately 200 nm. Anodic stripping voltammetry (ASV) was used to evaluate a solution composed of 1 x 10(-6) M Hg(2+), in the presence of the SPCE/PANI-MB polymer sensor electrode. The Hg(2+) ions were determined as follows: (i) pre-concentration and reduction on the modified electrode surface and (ii) subsequent stripping from the electrode surface during the positive potential sweep. The experimental conditions optimised for Hg(2+) determination included the supporting electrolyte concentration and the accumulation time. The results obtained have shown that the SPCE/PANI-MB polymer sensor electrode operates optimally at a pH 2, with the supporting electrolyte concentration at 0.5 M HCl. A linear calibration curve was found to be in the range of 1 x 10(-8) M to 1 x 10(-5) M Hg(2+) after 120 s of pre-concentration. The detection limit was calculated and found to be 54.27 +/- 3.28 mu g L(-1) of Hg(2+). The results have also shown that a conducting polymer modified SPCE sensor electrode can be used as an alternative transducer for the voltammetric stripping and analysis of inorganic Hg(2+) ions.
引用
收藏
页码:671 / 685
页数:15
相关论文
共 50 条
  • [1] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Nahid Shoaie
    Mehdi Forouzandeh
    Kobra Omidfar
    [J]. Microchimica Acta, 2018, 185
  • [2] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Shoaie, Nahid
    Forouzandeh, Mehdi
    Omidfar, Kobra
    [J]. MICROCHIMICA ACTA, 2018, 185 (04)
  • [3] Development and application of a poly(2,2′-dithiodianiline) (PDTDA)-coated screen-printed carbon electrode in inorganic mercury determination
    Somerset, Vernon
    Leaner, Joy
    Mason, Robert
    Iwuoha, Emmanuel
    Morrin, Aoife
    [J]. ELECTROCHIMICA ACTA, 2010, 55 (14) : 4240 - 4246
  • [4] Electrochemical Synthesis of Polyaniline Films at a Screen-printed Carbon Electrode and their Potential Applicability in Biosensing
    Stoces, Matej
    Kalcher, Kurt
    Svancara, Ivan
    Vytras, Karel
    [J]. MODERN ELECTROCHEMICAL METHODS XXX, 2010, : 158 - 162
  • [5] Polyaniline-chitosan modified on screen-printed carbon electrode for the electrochemical detection of perfluorooctanoic acid
    Suhaimi, Nur Farahin
    Baharin, Siti Nor Atika
    Jamion, Nurul Ain
    Zain, Zainiharyati Mohd
    Sambasevam, Kavirajaa Pandian
    [J]. MICROCHEMICAL JOURNAL, 2023, 188
  • [7] Anodic Voltammetric determination of gemifloxacin using screen-printed carbon electrode
    Radi, Abd-Elgawad
    Khafagy, Amira
    El-shobaky, Amira
    El-mezayen, Hatem
    [J]. JOURNAL OF PHARMACEUTICAL ANALYSIS, 2013, 3 (02) : 132 - 136
  • [8] Anodic voltammetric determination of gemifloxacin using screen-printed carbon electrode
    Abd-Elgawad Radi
    Amira Khafagy
    Amira El-shobaky
    Hatem El-mezayen
    [J]. Journal of Pharmaceutical Analysis, 2013, 3 (02) : 132 - 136
  • [9] Nonenzymatic coated screen-printed electrode for electrochemical determination of acetylcholine
    Sayed Zia Mohammadi
    Hadi Beitollahi
    Somayeh Tajik
    [J]. Micro and Nano Systems Letters, 6 (1)
  • [10] Investigation of electrochemical behaviour of polyaniline on carbon screen-printed electrodes for the detection of nitrite
    Adiraju, Anurag
    Al-Hamry, Ammar
    Kanoun, Olfa
    [J]. 2019 5TH INTERNATIONAL CONFERENCE ON NANOTECHNOLOGY FOR INSTRUMENTATION AND MEASUREMENT (NANOFIM), 2019,