Agreement Between Standard Optical Coherence Tomography and Optical Coherence Tomography-Based Angiography in Estimating Retinal Nerve Fiber Layer Thickness

被引:1
|
作者
Yilmaz, Hayati [1 ]
Koylu, Mehmet Talay [2 ]
Yilmaz, Alper Can [2 ]
Durukan, Ali Hakan [2 ]
Uysal, Yusuf [2 ]
机构
[1] Univ Hlth Sci Turkey, Umraniye Training & Res Hosp, Clin Ophthalmol, Istanbul, Turkey
[2] Univ Hlth Sci Turkey, Gulhane Med Fac, Dept Ophthalmol, Ankara, Turkey
关键词
Glaucoma; optical; coherence; angiography; agreement; SPECTRAL-DOMAIN; VESSEL DENSITY; STRATUS OCT; TIME-DOMAIN; NORMAL EYES; GLAUCOMA; HEALTHY; REPEATABILITY; DAMAGE; ABILITY;
D O I
10.4274/tjo.galenos.2020.18488
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To investigate the agreement between optical coherence tomography (OCT) and OCT-based angiography in estimating retinal nerve fiber layer thickness (RNFLT) and evaluate the associations between peripapillary vessel density (VD) and RNFLT measurements obtained with both devices. Materials and Methods: The AngioVue (Optovue Inc., Fremont, CA, USA) and Spectralis (Heidelberg Engineering, Heidelberg, Germany) images of 325 patients were screened retrospectively. RNFLT values were recorded using both devices. The intraclass correlation coefficient (ICC) and Bland-Altman plots were obtained to investigate the agreement between the devices. Age- and intraocular pressurecorrected associations between VD and RNFLT measured by the two devices were analyzed using linear regression models. Results: ICC revealed excellent agreement for global, superior, inferior, and temporal RNFLT and good agreement for the nasal quadrant (ICC=0.895, 0.936, 0.923, 0.887, and 0.614, respectively). The Bland-Altman plots showed poor agreement for all measurements with a large span of limits of agreement and significant proportional bias (p<0.05). VD was found to be strongly associated with the RNFLT measurements of both devices (p<0.001). Conclusion: The disagreement between the devices should be considered in clinical practice, and the data should not be used interchangeably. The association of the peripapillary VD with RNFLT using both devices indicated that RNFLT assessed by the AngioVue could be used in glaucoma management along with VD.
引用
收藏
页码:264 / 270
页数:7
相关论文
共 50 条
  • [41] Agreement between optical coherence tomography and histology derived retinal thickness measures
    Hutchings, N
    Martin, E
    Collier, R
    Lin, M
    Kapin, M
    Flanagan, JG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U292 - U292
  • [42] Relationship Between Standard Automated Perimetry and Retinal Nerve Fiber Layer Parameters Obtained With Optical Coherence Tomography
    Lopez-Pena, Maria J.
    Ferreras, Antonio
    Larrosa, Jose M.
    Polo, Vicente
    Pablo, Luis E.
    JOURNAL OF GLAUCOMA, 2011, 20 (07) : 422 - 432
  • [43] Retinal nerve fibre layer thickness measurements in myopia by optical coherence tomography
    Bubella, R. Morreale
    Bubella, D. Morreale
    ACTA OPHTHALMOLOGICA, 2014, 92
  • [44] Compensation of retinal nerve fiber layer thickness as assessed using optical coherence tomography based on anatomical confounders
    Chua, Jacqueline
    Schwarzhans, Florian
    Quang Nguyen
    Sia, Josh Tjunrong
    Wong, Tien Y.
    Aung, Tin
    Fischer, Georg
    Cheng, Ching-Yu
    Vass, Clemens
    Schmetterer, Leopold
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [45] Agreement of predicted and measured retinal nerve fiber layer thickness from spectral domain and time domain optical coherence tomography
    Laemmer, Robert
    Schrems, Wolfgang A.
    Schrems-Hoesl, Laura M.
    Horn, Folkert K.
    Kruse, Friedrich E.
    Mardin, Christian Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [46] Reproducibility of RTVue Retinal Nerve Fiber Layer Thickness and Optic Disc Measurements and Agreement with Stratus Optical Coherence Tomography Measurements
    Gonzalez-Garcia, Alberto O.
    Vizzeri, Gianmarco
    Bowd, Christopher
    Medeiros, Felipe A.
    Zangwill, Linda M.
    Weinreb, Robert N.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) : 1067 - 1074
  • [47] Retinal nerve fiber layer and optical coherence tomography angiography analysis in fibromyalgia using logistic regression
    Tello, Alvaro
    Castro-Roger, Luisa
    Palomar, Elisa Vilades
    Cordon Ciordia, Beatriz
    Jesus Rodrigo, Maria
    Subias Perie, Manuel
    Arias Campo, Lorena
    Vicente Altabas, Maria Jose
    Satue, Maria
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [48] Capillary Dropout at the Retinal Nerve Fiber Layer Defect in Glaucoma: An Optical Coherence Tomography Angiography Study
    Ichiyama, Yusuke
    Minamikawa, Takayuki
    Niwa, Yuichi
    Ohji, Masahito
    JOURNAL OF GLAUCOMA, 2017, 26 (04) : E142 - E145
  • [49] Comparison of reproducibility of retinal nerve fiber layer thickness measured by optical coherence tomography and nerve fiber analyzer.
    Yamada, K
    Osako, M
    Tachibana, K
    Okano, T
    Usui, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S18 - S18
  • [50] Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography
    Blumenthal, EZ
    Williams, JM
    Weinreb, RN
    Girkin, CA
    Berry, CC
    Zangwill, LM
    OPHTHALMOLOGY, 2000, 107 (12) : 2278 - 2282