Agreement Between Standard Optical Coherence Tomography and Optical Coherence Tomography-Based Angiography in Estimating Retinal Nerve Fiber Layer Thickness

被引:1
|
作者
Yilmaz, Hayati [1 ]
Koylu, Mehmet Talay [2 ]
Yilmaz, Alper Can [2 ]
Durukan, Ali Hakan [2 ]
Uysal, Yusuf [2 ]
机构
[1] Univ Hlth Sci Turkey, Umraniye Training & Res Hosp, Clin Ophthalmol, Istanbul, Turkey
[2] Univ Hlth Sci Turkey, Gulhane Med Fac, Dept Ophthalmol, Ankara, Turkey
关键词
Glaucoma; optical; coherence; angiography; agreement; SPECTRAL-DOMAIN; VESSEL DENSITY; STRATUS OCT; TIME-DOMAIN; NORMAL EYES; GLAUCOMA; HEALTHY; REPEATABILITY; DAMAGE; ABILITY;
D O I
10.4274/tjo.galenos.2020.18488
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To investigate the agreement between optical coherence tomography (OCT) and OCT-based angiography in estimating retinal nerve fiber layer thickness (RNFLT) and evaluate the associations between peripapillary vessel density (VD) and RNFLT measurements obtained with both devices. Materials and Methods: The AngioVue (Optovue Inc., Fremont, CA, USA) and Spectralis (Heidelberg Engineering, Heidelberg, Germany) images of 325 patients were screened retrospectively. RNFLT values were recorded using both devices. The intraclass correlation coefficient (ICC) and Bland-Altman plots were obtained to investigate the agreement between the devices. Age- and intraocular pressurecorrected associations between VD and RNFLT measured by the two devices were analyzed using linear regression models. Results: ICC revealed excellent agreement for global, superior, inferior, and temporal RNFLT and good agreement for the nasal quadrant (ICC=0.895, 0.936, 0.923, 0.887, and 0.614, respectively). The Bland-Altman plots showed poor agreement for all measurements with a large span of limits of agreement and significant proportional bias (p<0.05). VD was found to be strongly associated with the RNFLT measurements of both devices (p<0.001). Conclusion: The disagreement between the devices should be considered in clinical practice, and the data should not be used interchangeably. The association of the peripapillary VD with RNFLT using both devices indicated that RNFLT assessed by the AngioVue could be used in glaucoma management along with VD.
引用
收藏
页码:264 / 270
页数:7
相关论文
共 50 条
  • [31] Retinal nerve fiber layer thickness map determined from optical coherence tomography images
    Mujat, M
    Chan, RC
    Cense, B
    Park, BH
    Joo, C
    Akkin, T
    Chen, TC
    de Boer, JF
    OPTICS EXPRESS, 2005, 13 (23): : 9480 - 9491
  • [32] The Effect of Software Upgrade on Optical Coherence Tomography Measurement of the Retinal Nerve Fiber Layer Thickness
    Seibold, Leonard K.
    Kahook, Malik Y.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2012, 19 (04) : 392 - 396
  • [33] Optical Coherence Tomography Measurements of Retinal Nerve Fiber Layer Thickness in Chinese Children and Teenagers
    Qian, Jin
    Wang, Weijun
    Zhang, Xian
    Wang, Fenghua
    Jiang, Yuan
    Wang, Wenqiu
    Xu, Shan
    Wu, Ying
    Su, Yi
    Xu, Xun
    Sun, Xiaodong
    JOURNAL OF GLAUCOMA, 2011, 20 (08) : 509 - 513
  • [34] Retinal nerve fiber layer thickness in a healthy Turkish population measured by optical coherence tomography
    Cubuk, Mehmet
    Sahinoglu-Keskek, Nedime
    Keskek, Sakir Ozgur
    ANNALS OF SAUDI MEDICINE, 2016, 36 (06) : 409 - 413
  • [35] Retinal nerve fiber layer thickness and radial peripapillary capillaries density in myopic adults with optical coherence tomography angiography
    Ma, Chunhui
    Chen, Chunwen
    Zhang, Yutong
    Yao, Jingyan
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [36] Retinal vascularity, nerve fiber, and ganglion cell layer thickness in thyroid eye disease on optical coherence tomography angiography
    Dave, Tarjani Vivek
    Laghmisetty, Srujana
    Krishnamurthy, Gayatri
    Bejjanki, Kavya
    Ganguly, Anasua
    Jonnadula, Ganesh Babu
    Dave, Vivek Pravin
    Pappuru, Rajeev Reddy
    ORBIT-THE INTERNATIONAL JOURNAL ON ORBITAL DISORDERS-OCULOPLASTIC AND LACRIMAL SURGERY, 2022, 41 (02): : 170 - 177
  • [37] Peripapillary Retinal Nerve Fiber Layer Vascular Microcirculation in Glaucoma Using Optical Coherence Tomography-Based Microangiography
    Chen, Chieh-Li
    Zhang, Anqi
    Bojikian, Karine D.
    Wen, Joanne C.
    Zhang, Qinqin
    Xin, Chen
    Mudumbai, Raghu C.
    Johnstone, Murray A.
    Chen, Philip P.
    Wang, Ruikang K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT475 - OCT485
  • [38] Comparison of retinal nerve fiber layer thickness measured by optical coherence tomography 2 versus optical coherence tomography 3 in patients with optic nerve head drusen
    Patel, HC
    Reynolds, AC
    Farris, BK
    Skuta, GL
    Siatkowski, RM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U239 - U239
  • [39] Optical coherence tomography angiography of the correlation between radial peripapillary capillary density and retinal nerve fiber layer thickness in healthy eyes
    Wang, Jie
    Simonett, Joseph
    Hua, Xiaohui
    Liu, Liang
    Hwang, Thomas S.
    Huang, David
    Jia, Yali
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [40] Relationship between visual field sensitivity and retinal nerve fiber layer thickness as measured by optical coherence tomography
    Ajtony, Csilla
    Balla, Zsolt
    Somoskeoy, Szabolcs
    Kovacs, Balint
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (01) : 258 - 263