Normoxic polyacrylamide gel doped with iodine: Response versus X-ray energy

被引:11
|
作者
Gastaldo, Jerome [1 ,2 ,3 ]
Boudou, Caroline [1 ,2 ,3 ]
Lamalle, Laurent [4 ]
Tropres, Irene [4 ]
Corde, Stephanie [5 ]
Sollier, Alberic [5 ]
Rucka, Guenther [5 ]
Elleaume, Helene [1 ,2 ,3 ]
机构
[1] Equipe Rayonnement Synchrotron & Rech Med, Grenoble Inst Neurosci, INSERM, Unite 836, F-38043 Grenoble 9, France
[2] Univ Grenoble 1, F-38041 Grenoble 9, France
[3] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[4] CHU Grenoble, IFR 1, RMN Biomed & Neurosci, Unite IRM 3T, F-38043 Grenoble 9, France
[5] CHU Grenoble, Dept Radiotherapie, F-38043 Grenoble, France
关键词
Synchrotron radiation; Dosimetry; Polymer gel; Radiotherapy; Iodine dose-enhancement;
D O I
10.1016/j.ejrad.2008.04.053
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The basis of Synchrotron Stereotactic Radio-Therapy (SSRT) is the incorporation of high atomic number atoms (iodine, for example) into the tumour mass followed by an irradiation with a monochromatic, low energy, X-ray beam from a synchrotron Source. The purpose of the present study was to determine whether polymer gel dosimetry Could be used to measure the enhancement of absorbed energy induced by the iodine in the media. We have used a standard nPAG formulation, loaded with NaI and the irradiations were performed either with monochromatic X-rays at the ESRF medical beamline or with a conventional 6 MV X-ray beam from a linear accelerator at the Grenoble University Hospital. We observed sensitivity increase with iodine loaded gels irradiated at low energies, in good agreement with the theoretical iodine dose-enhancement. As expected, the response of the iodine-doped polymer gel was not increased after irradiation with mega-voltage X-rays. We demonstrate in this study that polymer act dosimeters can be used for measuring dose-enhancement due to iodine presence in SSR treatment. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:S118 / S120
页数:3
相关论文
共 50 条
  • [11] X-RAY PHOTOELECTRON-SPECTROSCOPY STUDY OF THE INTERACTION WITH IODINE DOPED POLYETHYNYLFERROCENE
    POLZONETTI, G
    FARUFFINI, V
    FURLANI, A
    RUSSO, MV
    [J]. SYNTHETIC METALS, 1989, 29 (01) : E495 - E499
  • [12] Energy Response of Tb3+-Doped Silicate Scintillating Glass to Hard X-Ray
    Gao Qing-chun
    Gu Mu
    Huang Shi-ming
    Liu Bo
    Ni Chen
    Liu Xiao-lin
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (06) : 1720 - 1722
  • [13] POLYCHROMATIC X-RAY ATTENUATION PROPERTIES OF NORMOXIC POLYMERS GELS
    Sevcik, Aleksandras
    Adliene, Diana
    [J]. MEDICAL PHYSICS IN THE BALTIC STATES, 2019, : 79 - 84
  • [14] Energy response characterization of InGaP X-ray detectors
    Lioliou, G.
    Krysa, A. B.
    Barnett, A. M.
    [J]. JOURNAL OF APPLIED PHYSICS, 2018, 124 (19)
  • [15] Energy response characterization of InGaP X-ray detectors
    [J]. Lioliou, G. (g.lioliou@sussex.ac.uk), 1600, American Institute of Physics Inc. (124):
  • [16] X-ray energy response of silicon (B): Measurements
    Univ of Leicester, Leicester, United Kingdom
    [J]. Nucl Instrum Methods Phys Res Sect A, 3 (503-510):
  • [17] DOSIMETER X-RAY RESPONSE AS A FUNCTION OF CALIBRATION ENERGY
    HOLBROOK, KL
    FIX, JJ
    HOOKER, CD
    [J]. HEALTH PHYSICS, 1982, 43 (01): : 139 - 139
  • [18] Determination of paramagnetic gel sensitivity in low energy X-ray beam
    Ben Ahmed, Y.
    Coulaud, J.
    Ken, S.
    Parent, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S785 - S785
  • [19] X-RAY PHOTOELECTRON SPECTROSCOPIC STUDY OF HIGHLY CONDUCTIVE IODINE-DOPED POLYACETYLENE
    IKEMOTO, I
    SAKAIRI, M
    TSUTSUMI, T
    KURODA, H
    HARADA, I
    TASUMI, M
    SHIRAKAWA, H
    IKEDA, S
    [J]. CHEMISTRY LETTERS, 1979, (10) : 1189 - 1192
  • [20] A preliminary study of the novel application of normoxic polymer gel dosimeters for the measurement of CTDI on diagnostic x-ray CT scanners
    Hill, B
    Venning, AJ
    Baldock, C
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1589 - 1597