Patient neutron dose equivalent exposures outside of the proton therapy treatment field

被引:47
|
作者
Polf, JC [1 ]
Newhauser, WD [1 ]
Titt, U [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
关键词
D O I
10.1093/rpd/nci264
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A large fraction of dose to healthy tissue located outside of the treatment field during proton therapy is attributable to neutrons produced in the beam-delivery apparatus. In this work, the neutron dose equivalent (H) per therapeutic proton absorbed dose (D) was estimated for typical treatment conditions as a function of range modulation width, angle with respect to the incident proton beam, and the distance from the isocentre at the Harvard Cyclotron Laboratory's (Cambridge, MA) passively spread treatment field using Monte Carlo simulations. For a beam with 16 cm penetration (depth) and a 5 x 5cm(2) lateral field size at the patient location along the incident beam direction at 100 cm from the isocentre, the predicted HID values are 0.35 and 0.60 mSv Gy(-1) from the simulations and measurements, respectively. At an locations, the predicted HID values are within a factor of 2 and 3 of the measured result for no modulation and 8.2 cm of modulation, respectively.
引用
收藏
页码:154 / 158
页数:5
相关论文
共 50 条
  • [1] Effects of choice of the MLC material on neutron dose equivalent outside of the treatment field in proton therapy
    Goulart, D.
    Maughan, R.
    McDonough, J.
    Avery, S.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2198 - 2198
  • [2] Measurement of neutron dose equivalent to proton therapy patients outside of the proton radiation field
    Yan, X
    Titt, U
    Koehler, AM
    Newhauser, WD
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2): : 429 - 434
  • [3] Effect of range modulation on neutron dose equivalent exposures around a passive scattering proton therapy treatment nozzle
    Polf, J
    Newhauser, W
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2164 - 2164
  • [4] Measurement of neutron dose equivalent outside and inside of the treatment vault of GRID therapy
    Wang, Xudong
    Charlton, Michael A.
    Esquivel, Carlos
    Eng, Tony Y.
    Li, Ying
    Papanikolaou, Nikos
    [J]. MEDICAL PHYSICS, 2013, 40 (09)
  • [5] Calculations of neutron dose equivalent exposures from range-modulated proton therapy beams
    Polf, JC
    Newhauser, WD
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16): : 3859 - 3873
  • [6] NEUTRON DOSE EQUIVALENT OUTSIDE A NEUTRON THERAPY FACILITY AS DETERMINED BY AN LET COUNTER
    STINCHCOMB, TG
    KUCHNIR, FT
    [J]. MEDICAL PHYSICS, 1981, 8 (01) : 140 - 140
  • [7] Experimental Study of Neutron Dose Equivalent in a Proton Treatment Facility
    Wang, X.
    Gillin, M.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2982 - +
  • [8] AMBIENT DOSE EQUIVALENT VERSUS EFFECTIVE DOSE FOR QUANTIFYING STRAY RADIATION EXPOSURES TO A PATIENT RECEIVING PROTON THERAPY FOR PROSTATE CANCER
    Fontenot, Jonas D.
    Taddei, Phillip
    Zheng, Yuanshui
    Mirkovic, Dragan
    Newhauser, Wayne D.
    [J]. NUCLEAR TECHNOLOGY, 2009, 168 (01) : 173 - 177
  • [9] Scattered neutron dose equivalent to a fetus from proton therapy of the mother
    Roy, SC
    Sandison, GA
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 997 - 998
  • [10] The effect of field size on neutron dose equivalent around the target in proton beams
    Romero-Exposito, M.
    Romero-Exposito, M.
    Dasu, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1553 - S1553