Cone-beam image reconstruction from equi-angular sampling using spherical harmonics

被引:1
|
作者
Taguchi, K [1 ]
Zeng, GSL [1 ]
Gullberg, GT [1 ]
机构
[1] Toshiba Co Ltd, Ctr Res & Dev, Med Syst Co, Otawara, Tochigi 3248550, Japan
关键词
image reconstruction; cone-beam; spherical harmonics; short-object problem; equi-angular sampling;
D O I
10.1117/12.431166
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
All of exact cone-beam reconstruction algorithms(6-8) for so called "long-object problem" do not use equi-angular sampling but use equi-space sampling. However, cylindrical detectors (equi-angular sampling in xy and equi-spatial in z) have advantage in their compact design. Therefore, toward the long-object problem with equi-angular sampling, the purpose of this study is to develop a cone-beam reconstruction algorithm using equi-angular sampling for short-object problem. A novel implementation of Grangeat's algorithm(9) using equi-angular sampling has been developed for short-object problem with and without detector truncation. First, both cone-beam projection g(psi) (theta,phi) and the first derivative of plane integral (3D Radon transform) (p) over tilde (<(<psi>)over bar>) (theta,phi) are described using spherical harmonics with equi-angular sampling. Then, using Grangeat's formula, relationship between coefficients of spherical harmonics for g(<(<psi>)over bar>) (theta,phi) and (p) over tilde (<(<psi>)over bar>) (theta,phi) are found. Finally, a method has been developed to obtain (p) over tilde (<(<psi>)over bar>) (theta,phi) from cone-beam projection data in which the object is partially scanned. Images are reconstructed using the 3D Radon backprojection with rebinning. Computer simulations were performed in order to verify this approach: Isolated (axially bounded) objects were scanned both with circular and helical orbits. When the orbit of the cone vertex does not satisfy Tuy's data sufficiency conditions, strong oblique shadows and blurring in the axial direction were shown in reconstructed coronal images. On the other hand, if the trajectory satisfies Tuy's data sufficiency condition, the proposed algorithm provides an exact reconstruction. In conclusion, a novel implementation of the Grangeat's algorithm for cone-beam image reconstruction using equi-angular sampling has been developed.
引用
下载
收藏
页码:867 / 876
页数:4
相关论文
共 50 条
  • [1] Cone-beam image reconstruction using spherical harmonics
    Taguchi, K
    Zeng, GSL
    Gullberg, GT
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (06): : N127 - N138
  • [2] Cone-Beam CT Image Reconstruction with Spherical Harmonics
    Shimomura, T.
    Haga, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E391 - E392
  • [3] Cone-beam and fan-beam image reconstruction algorithms based on spherical and circular harmonics
    Zeng, GSL
    Gullberg, GT
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11): : 2239 - 2256
  • [4] Image reconstruction in cone-beam CT with a spherical detector using the BPF algorithm
    Zuo, Nianming
    Zou, Yu
    Jiang, Tianzi
    Pan, Xiaochuan
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [5] Image reconstruction from truncated cone-beam projections
    Schomberg, H
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 575 - 578
  • [6] Image reconstruction from minimum helical cone-beam projections
    Zou, Y
    Pan, XC
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 2083 - 2088
  • [7] Cone-beam image reconstruction by moving frames
    Yang, XC
    Horn, BKP
    COMPUTER VISION AND MATHEMATICAL METHODS IN MEDICAL AND BIOMEDICAL IMAGE ANALYSIS, 2004, 3117 : 35 - 47
  • [8] An efficient linogram sampling method for cone-beam reconstruction
    Kudo, H
    Saito, T
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1165 - 1169
  • [9] Fast cone-beam CT image reconstruction using GPU hardware
    Yan, Guorui
    Tian, Jie
    Zhu, Shouping
    Dai, Yakang
    Qin, Chenghu
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2008, 16 (04) : 225 - 234
  • [10] Fast cone-beam CT image reconstruction using GPU hardware
    Key Laboratory of Complex Systems and Intelligence Science, Graduate School of the Chinese Academy of Sciencesacty, Chinese Academy of Sciences, P. O. Box 2728, Beijing, 100190, China
    J X Ray Sci Technol, 2008, 4 (225-234):