Image reconstruction from minimum helical cone-beam projections

被引:0
|
作者
Zou, Y [1 ]
Pan, XC [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
D O I
10.1117/12.536591
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
We proposed a new reconstruction algorithm for image reconstruction from helical cone-beam data only within the Tam-Danielsson window, thus allowing the potential reduction of radiation dose to patients. The new algorithm can be expressed as two terms. The first term dominates the contribution to the reconstructed image, and the second term provides only a small correction. In fact. such a correction is generally negligible as compared to that from the first term and introduces a detectable DC-type shift to the reconstructed images only in the situations where the ratio between the size of field of view and the helical radius approaches to 0.625, which is the limit to the validity of the first term. Based on the Grangeat formula. we have developed an algorithm to calculate the correction (i.e., the second) term from the data within the window.
引用
收藏
页码:2083 / 2088
页数:6
相关论文
共 50 条
  • [1] Image reconstruction from truncated cone-beam projections
    Schomberg, H
    [J]. 2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 575 - 578
  • [2] Reconstruction from minimum data in helical cone-beam CT
    Zou, Y
    Pan, XC
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3235 - 3238
  • [3] An improved PI-method for reconstruction from helical cone-beam projections
    Turbell, H
    Danielson, PE
    [J]. 1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 865 - 868
  • [4] An Improved Helical Cone-beam CT Image Reconstruction
    Gao, Yang
    Ma, Jianhua
    Chen, Wufan
    [J]. 2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2178 - 2182
  • [5] Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT
    Zou, Y
    Pan, XC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (06): : 941 - 959
  • [6] Image reconstruction from misaligned truncated helical cone-beam data
    Noo, F
    Schaller, S
    Clackdoyle, R
    White, TA
    Roney, TJ
    [J]. 1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1028 - 1032
  • [7] Image reconstruction from rebinned helical cone-beam projection data
    Xia, Dan
    Yu, Lifeng
    Bian, Junguo
    Pan, Xiaochuan
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [8] Derivative-Hilbert-Backprojection based image reconstruction from truncated projections in helical cone-beam CT
    Zhang Feng
    Yan Bin
    Li Lei
    Xi Xiao-Qi
    Jiang Hua
    Wei Xing
    Zhang Xiang
    Cui Jin-Xian
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2015, 26 (02)
  • [9] Derivative-Hilbert-Backprojection based image reconstruction from truncated projections in helical cone-beam CT
    张峰
    闫镔
    李磊
    席晓琦
    江桦
    魏星
    张翔
    崔进鲜
    [J]. Nuclear Science and Techniques, 2015, 26 (02) : 49 - 57
  • [10] IMAGE-RECONSTRUCTION FROM CONE-BEAM PROJECTIONS - NECESSARY AND SUFFICIENT CONDITIONS AND RECONSTRUCTION METHODS
    SMITH, BD
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1985, 4 (01) : 14 - 25