Cone-beam image reconstruction from equi-angular sampling using spherical harmonics

被引:1
|
作者
Taguchi, K [1 ]
Zeng, GSL [1 ]
Gullberg, GT [1 ]
机构
[1] Toshiba Co Ltd, Ctr Res & Dev, Med Syst Co, Otawara, Tochigi 3248550, Japan
关键词
image reconstruction; cone-beam; spherical harmonics; short-object problem; equi-angular sampling;
D O I
10.1117/12.431166
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
All of exact cone-beam reconstruction algorithms(6-8) for so called "long-object problem" do not use equi-angular sampling but use equi-space sampling. However, cylindrical detectors (equi-angular sampling in xy and equi-spatial in z) have advantage in their compact design. Therefore, toward the long-object problem with equi-angular sampling, the purpose of this study is to develop a cone-beam reconstruction algorithm using equi-angular sampling for short-object problem. A novel implementation of Grangeat's algorithm(9) using equi-angular sampling has been developed for short-object problem with and without detector truncation. First, both cone-beam projection g(psi) (theta,phi) and the first derivative of plane integral (3D Radon transform) (p) over tilde (<(<psi>)over bar>) (theta,phi) are described using spherical harmonics with equi-angular sampling. Then, using Grangeat's formula, relationship between coefficients of spherical harmonics for g(<(<psi>)over bar>) (theta,phi) and (p) over tilde (<(<psi>)over bar>) (theta,phi) are found. Finally, a method has been developed to obtain (p) over tilde (<(<psi>)over bar>) (theta,phi) from cone-beam projection data in which the object is partially scanned. Images are reconstructed using the 3D Radon backprojection with rebinning. Computer simulations were performed in order to verify this approach: Isolated (axially bounded) objects were scanned both with circular and helical orbits. When the orbit of the cone vertex does not satisfy Tuy's data sufficiency conditions, strong oblique shadows and blurring in the axial direction were shown in reconstructed coronal images. On the other hand, if the trajectory satisfies Tuy's data sufficiency condition, the proposed algorithm provides an exact reconstruction. In conclusion, a novel implementation of the Grangeat's algorithm for cone-beam image reconstruction using equi-angular sampling has been developed.
引用
下载
收藏
页码:867 / 876
页数:4
相关论文
共 50 条
  • [21] Image Reconstruction Using OS-EM Method in Cone-beam CT
    Dong, Baoyu
    2008 IEEE INTERNATIONAL SYMPOSIUM ON KNOWLEDGE ACQUISITION AND MODELING WORKSHOP PROCEEDINGS, VOLS 1 AND 2, 2008, : 108 - 111
  • [22] Cone-beam filtered backprojection image reconstruction using a factorized weighting function
    Chen, Guang-Hong
    Zhuang, Ting-Liang
    Leng, Shuai
    Nett, Brian E.
    OPTICAL ENGINEERING, 2007, 46 (08)
  • [23] Statistical Cone-Beam CT Image Reconstruction using the Cell Broadband Engine
    Knaup, Michael
    Kalender, Willi A.
    Kachelriess, Marc
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2837 - 2840
  • [24] A CONE-BEAM RECONSTRUCTION ALGORITHM USING SHIFT-VARIANT FILTERING AND CONE-BEAM BACKPROJECTION
    DEFRISE, M
    CLACK, R
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (01) : 186 - 195
  • [25] Angular weighted hybrid cone-beam CT reconstruction for circular trajectories
    Grass, M
    Köhler, T
    Proksa, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (06): : 1595 - 1610
  • [26] Generalized Feldkamp image reconstruction from equiangular cone-beam projection data
    Wang, B
    Liu, H
    Wang, G
    13TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS 2000), PROCEEDINGS, 2000, : 123 - 128
  • [27] Image reconstruction from cone-beam data on a circular short-scan
    Noo, F
    Heuscher, DJ
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 50 - 59
  • [28] IMAGE RECONSTRUCTION FROM CONE-BEAM PROJECTIONS: NECESSARY AND SUFFICIENT CONDITIONS AND RECONSTRUCTION METHODS.
    Smith, Bruce D.
    IEEE Transactions on Medical Imaging, 1985, MI-4 (01) : 14 - 25
  • [29] IMAGE-RECONSTRUCTION FROM CONE-BEAM PROJECTIONS - NECESSARY AND SUFFICIENT CONDITIONS AND RECONSTRUCTION METHODS
    SMITH, BD
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1985, 4 (01) : 14 - 25
  • [30] Fast parallel image reconstruction for cone-beam FDK algorithm
    Zhang, Shunli
    Geng, Guohua
    Zhao, Jian
    CONCURRENCY AND COMPUTATION-PRACTICE & EXPERIENCE, 2019, 31 (10):