Use of a Dedicated Pediatric CT Imaging Service Associated With Decreased Patient Radiation Dose

被引:15
|
作者
Borders, Heather L. [1 ,2 ,3 ]
Barnes, Courtney L. [2 ]
Parks, David C. [2 ]
Jacobsen, Jerilynn R. [2 ]
Zhou, Yong [2 ]
Hasselquist, Bruce E. [2 ]
Betz, Bradford W. [1 ,2 ,3 ]
机构
[1] Adv Radiol Serv PC, Grand Rapids, MI 49509 USA
[2] Spectrum Hlth Helen DeVos Childrens Hosp, Grand Rapids, MI USA
[3] Michigan State Univ, Coll Human Med, Grand Rapids, MI USA
关键词
Pediatric; CT; ALARA; radiation dose; COMPUTED-TOMOGRAPHY; REDUCTION;
D O I
10.1016/j.jacr.2011.12.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The growing use of CT as a diagnostic imaging tool has led to increased concern over radiation dose, particularly in pediatric patients. The ALARA concept has been popularized in dose reduction. ALARA supports the use of low-dose, pediatric-specific protocols. Strict adherence to low-dose protocols can be challenging, particularly in a high-volume radiology department that scans both pediatric and adult patients. The aim of this study was to determine whether the relocation of pediatric radiologic services from a combined high-volume pediatric and adult hospital to a children's hospital improves compliance with adjusted lower CT exposure parameters and thus the estimated effective dose of radiation delivered to pediatric patients. Methods: A retrospective review of abdominal and pelvic CT console dose and exposure parameter data on 495 patients from a combined pediatric and adult radiology department and subsequently 244 patients from a dedicated pediatric radiology department was performed. The console dose-length product was converted to estimated effective dose. Patients were divided into 1 of 8 weight categories for analysis. Results: A statistically significant decrease in the estimated effective dose for abdominal and pelvic CT studies was observed in all but one of the weight categories at the pediatric radiology department compared with the pediatric and adult radiology department. Conclusions: Imaging pediatric patients in a dedicated pediatric imaging department with dedicated pediatric CT technologists may result in greater compliance with pediatric protocols and significantly reduced patient dose. Conversely, greater scrutiny of compliance with pediatric dose-adjusted CT protocols may be necessary for departments that scan both children and adults.
引用
收藏
页码:340 / 343
页数:4
相关论文
共 50 条
  • [21] RADIATION-DOSE REDUCTION IN PEDIATRIC CT
    ROBINSON, AE
    HILL, EP
    HARPEN, MD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (03) : 695 - 695
  • [22] RADIATION-DOSE REDUCTION IN PEDIATRIC CT
    ROBINSON, AE
    HILL, EP
    HARPEN, MD
    PEDIATRIC RADIOLOGY, 1986, 16 (01) : 53 - 54
  • [23] RADIATION-DOSE REDUCTION IN PEDIATRIC CT
    HILL, EP
    ALABAMA JOURNAL OF MEDICAL SCIENCES, 1984, 21 (03): : 326 - 326
  • [24] Pediatric CT: Strategies to Lower Radiation Dose
    Zacharias, Claudia
    Alessio, Adam M.
    Otto, Randolph K.
    Iyer, Ramesh S.
    Philips, Grace S.
    Swanson, Jonathan O.
    Thapa, Mahesh M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) : 950 - 956
  • [25] RADIATION-DOSE REDUCTION IN PEDIATRIC CT
    ROBINSON, AE
    HILL, EP
    HARPEN, MD
    PEDIATRIC RADIOLOGY, 1985, 15 (01) : 69 - 69
  • [26] PEDIATRIC CT RADIATION-DOSE REDUCTION
    HILL, EP
    ROBINSON, AE
    HARPEN, MD
    INVESTIGATIVE RADIOLOGY, 1984, 19 (05) : S12 - S12
  • [27] Evaluation of radiation dose to pediatric models from whole body PET/CT imaging
    Mohammadi, Najmeh
    Akhlaghi, Parisa
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (04):
  • [28] Low dose multislice CT in the pediatric patient
    Hojreh, A
    Kainberger, F
    Puig, S
    RADIOLOGE, 2003, 43 (12): : 1051 - 1055
  • [29] CT dose reduction strategies and the pediatric patient
    Cody, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1834 - 1834
  • [30] CT dose reduction strategies and the pediatric patient
    Cody, D
    MEDICAL PHYSICS, 2003, 30 (06) : 1441 - 1441