Precision and accuracy of commercial assays for vancomycin therapeutic drug monitoring: evaluation based on external quality assessment scheme

被引:19
|
作者
Chen, Chao-Yang [1 ]
Li, Meng-Ya [1 ,2 ]
Ma, Ling-Yun [1 ]
Zhai, Xing-Yu [1 ,2 ]
Luo, Dao-Huang [1 ,2 ]
Zhou, Ying [1 ,2 ]
Liu, Zhen-Ming [3 ]
Cui, Yi-Min [1 ,2 ]
机构
[1] Peking Univ, Dept Pharm, Hosp 1, Beijing, Peoples R China
[2] Peking Univ, Sch Pharmaceut Sci, Dept Pharm Adm & Clin Pharm, Hlth Sci Ctr, Beijing, Peoples R China
[3] Peking Univ, Sch Pharmaceut Sci, State Key Lab Nat & Biomimet Drugs, Hlth Sci Ctr, Beijing, Peoples R China
关键词
FLUORESCENCE POLARIZATION IMMUNOASSAY; LIQUID-CHROMATOGRAPHY; PERFORMANCE; PHARMACOKINETICS; STANDARD; SERUM;
D O I
10.1093/jac/dkaa150
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Vancomycin remains a mainstay of the treatment of Gram-positive bacterial infections. It is crucial to accurately determine vancomycin serum concentration for adequate dose adjustment. Objectives: To evaluate the precision and accuracy of commercial assay techniques for vancomycin concentration and to assess the comparability of vancomycin detection methods in Chinese laboratories. Methods: Human serum samples spiked with known concentrations of vancomycin were provided to laboratories participating in the external quality assessment scheme (EQAS). Assay methods included chemiluminescence, enzyme immunoassay (EIA) and so on. The dispersion of the measurements was analysed and the robust coefficient of variation (rCV), relative percentage difference (RPD) and satisfactory rate for method groups were calculated. Moreover, performance of the Chinese laboratories was assessed. Results: A total of 657 results from 75 laboratories were collected, including 84 samples from 10 Chinese laboratories. The median rCV, median RPD and satisfactory rates classified by methods ranged from 1.85% to 15.87%, #14.75% to 13.34% and 94.59% to 100.00%, respectively. Significant differences were seen in precision, between kinetic interaction of microparticles in solution (KIMS) and other methods, and in accuracy, between enzyme-multiplied immunoassay technique (EMIT), fluorescence polarization immunoassay (FPIA) and other techniques. Vancomycin detection in China mainly depended on the chemiluminescence and EMIT methods, which tended to result in lowermeasurements. Conclusions: Although almost all assays in this study achieved an acceptable performance for vancomycin serumconcentration monitoring, obvious inconsistencies between methods were still observed. Chinese laboratories were more likely to underestimate vancomycin concentrations. Thus, recognizing inconsistencies between methods and regular participation in vancomycin EQAS are essential.
引用
收藏
页码:2110 / 2119
页数:10
相关论文
共 50 条
  • [1] Evaluation of commercial assays for vancomycin and aminoglycosides in serum: a comparison of accuracy and precision based on external quality assessment
    Wilson, JF
    Davis, AC
    Tobin, CM
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2003, 52 (01) : 78 - 82
  • [2] Evaluation of assays for aminoglycosides in serum:a comparison of accuracy and precision based on external quality assessment
    LI Meng-ya
    CHEN Chao-yang
    LEI Li-li
    Zhao Xia
    ZHOU Ying
    CUI Yi-min
    中国药理学与毒理学杂志, 2019, (10) : 815 - 816
  • [3] Vancomycin therapeutic drug monitoring: Is there a consensus view? The results of a UK National External Quality Assessment Scheme (UK NEQAS) for Antibiotic Assays questionnaire
    Tobin, CM
    Darville, JM
    Thomson, AH
    Sweeney, G
    Wilson, JF
    MacGowan, AP
    White, LO
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2002, 50 (05) : 713 - 718
  • [4] Evaluation of Assays to Measure Aminoglycosides in Serum: Comparison of Accuracy and Precision Based on External Quality Assessment
    Li, Mengya
    Ma, Lingyun
    Chen, Chaoyang
    Lei, Lili
    Zhai, Xingyu
    Luo, Daohuang
    Zhou, Ying
    Cui, Yimin
    THERAPEUTIC DRUG MONITORING, 2020, 42 (05) : 710 - 715
  • [5] An audit of therapeutic drug monitoring service provision by laboratories participating in an external quality assessment scheme
    Thomson, AH
    Watson, ID
    Wilson, JF
    Sweeney, G
    Dawkins, CE
    Smith, BL
    Williams, J
    Capps, NE
    Toseland, PA
    THERAPEUTIC DRUG MONITORING, 1998, 20 (03) : 248 - 252
  • [6] How Appropriate is Therapeutic Drug Monitoring for Lithium? Data from the Belgian External Quality Assessment Scheme
    Delattre, I. K.
    Coucke, W.
    Soumali, R.
    Van de Walle, P.
    Wallemacq, P.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 700 - 700
  • [7] How appropriate is therapeutic drug monitoring for lithium? Data from the Belgian external quality assessment scheme
    Delattre, I. K.
    Van de Walle, P.
    Van Campenhout, C.
    Neels, H.
    Verstraete, A. G.
    Wallemacq, P.
    CLINICAL BIOCHEMISTRY, 2015, 48 (09) : 617 - 621
  • [8] Critical assessment of the revised guidelines for vancomycin therapeutic drug monitoring
    Aljutayli, Abdullah
    Thirion, Daniel J. G.
    Nekka, Fahima
    BIOMEDICINE & PHARMACOTHERAPY, 2022, 155
  • [9] Validation of two commercial assays for therapeutic drug monitoring of adalimumab biosimilars
    Berghmans, R.
    Naudts, J.
    Ferkinghoff, B.
    Goren, H.
    Henke, M. L.
    Lennerz, A.
    Van Stappen, T.
    JOURNAL OF CROHNS & COLITIS, 2020, 14 : S563 - S563
  • [10] Gentamicin and vancomycin therapeutic drug monitoring in newborns: evaluation of practices
    Zaugg, C.
    Guignard, B.
    Pfister, R.
    Rimensberger, P.
    Rollason, V.
    Desmeules, J.
    Fonzo-Christe, C.
    Bonnabry, P.
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACY, 2011, 33 (02) : 463 - 463