Research on Non-Fault-Phase Current Characteristics in GroundING Fault in Power Transmission Grid

被引:0
|
作者
Song, Shuang [1 ]
Yang, Yifei [2 ]
Yuan, Yubo [1 ]
Liu, Yu [1 ]
Li, Peng [1 ]
Wang, Ye [1 ]
机构
[1] Jiangsu Elect Power Co, Res Inst, Nanjing 210003, Jiangsu, Peoples R China
[2] Nanjing Univ Sci & Technol, Nanjing 210094, Jiangsu, Peoples R China
关键词
Neutral-Point Grounded System; Grounding Fault; Non-Fault-Phase Current; Complete Electrical Parameters Model; RTDS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When grounding fault occurs in power transmission line in neutral-point grounded system, fault current of the fault phase tends to increase dramatically. In the meantime, the amplitude and phase of the current of non-fault phase also changes abruptly in some degree due to mutual inductance between phases. Firstly, by building model with complete electrical parameters based on induction between phases, this paper illustrates current characteristics of non-fault phase when single-phase grounding occurs in system with neutral-point solid grounding using physical conception. Then, RTDS model is built incorporating parameters of actual system to verify the accuracy and validity of the analysis model with complete electrical parameters using real-time simulation. In conclusion, amplitude and phase of non-fault phase is influenced by load condition, position of fault, system impedance, line impedance, etc., which offer favorable references for judging grid fault characteristics and positioning of fault in a fast and effective way.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Analysis of single-phase grounding fault characteristics of low resistance grounding system with multi-distributed power supply
    Tian, Junyang
    Li, Haiyong
    Jiang, Liandian
    Shen, Zizheng
    Ren, Haolin
    Guo, Liwei
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (14): : 103 - 110
  • [42] Influence of Potential Difference Within Large Grounding Grid on Fault Current Division Factor
    Zhang, Bo
    Jiang, Yukuan
    Wu, Jinpeng
    He, Jinliang
    IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (04) : 1752 - 1759
  • [43] Efficient reduction of fault current through the grounding grid of substation supplied by cable line
    Popovic, LM
    IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (02) : 556 - 561
  • [44] Fault Current-Division Factor of Substation Grounding Grid in Seasonal Frozen Soil
    He, Jinliang
    Wu, Jinpeng
    Zhang, Bo
    Zeng, Rong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (02) : 855 - 865
  • [45] Efficient reduction of fault current through the grounding grid of a substation supplied by an overhead line
    Popovic, Ljubivoje M.
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2006, 16 (03): : 247 - 259
  • [46] RESEARCH ON SINGLE-PHASE TO GROUND FAULT IN RESONANT GROUNDING SYSTEM
    Zhang Jian
    Duan Li-xiao
    Dou Zhan-liang
    2011 INTERNATIONAL CONFERENCE ON INSTRUMENTATION, MEASUREMENT, CIRCUITS AND SYSTEMS ( ICIMCS 2011), VOL 1: INSTRUMENTATION, MEASUREMENT, CIRCUITS AND SYSTEMS, 2011, : 459 - 463
  • [47] Fault current measurement method for single phase grounding of non-solidly earthed overhead lines
    Shandong University, Jinan 250061, China
    不详
    不详
    不详
    Dianli Xitong Zidonghue, 2008, 9 (74-78):
  • [48] Fault Current Limitation Coordination in Power Transmission System With Superconducting Fault Current Limiting Cables (SFCLC)
    Kojima, Hiroki
    Osawa, Takeshi
    Hayakawa, Naoki
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (03)
  • [49] Analysis of the operational characteristics of a grounding transformer when there is a single-phase grounding fault of the system
    Chen, Lei
    Xian, Richang
    Zheng, Chunxu
    Gao, Hongpeng
    Fan, Huifang
    Zhang, Bingqian
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (12): : 56 - 64
  • [50] A new optimization algorithm for grounding grid fault diagnosis
    Qiu, Qi-rong
    Wang, Peng
    WMSO: 2008 INTERNATIONAL WORKSHOP ON MODELLING, SIMULATION AND OPTIMIZATION, PROCEEDINGS, 2009, : 294 - 297