Research on Non-Fault-Phase Current Characteristics in GroundING Fault in Power Transmission Grid

被引:0
|
作者
Song, Shuang [1 ]
Yang, Yifei [2 ]
Yuan, Yubo [1 ]
Liu, Yu [1 ]
Li, Peng [1 ]
Wang, Ye [1 ]
机构
[1] Jiangsu Elect Power Co, Res Inst, Nanjing 210003, Jiangsu, Peoples R China
[2] Nanjing Univ Sci & Technol, Nanjing 210094, Jiangsu, Peoples R China
关键词
Neutral-Point Grounded System; Grounding Fault; Non-Fault-Phase Current; Complete Electrical Parameters Model; RTDS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When grounding fault occurs in power transmission line in neutral-point grounded system, fault current of the fault phase tends to increase dramatically. In the meantime, the amplitude and phase of the current of non-fault phase also changes abruptly in some degree due to mutual inductance between phases. Firstly, by building model with complete electrical parameters based on induction between phases, this paper illustrates current characteristics of non-fault phase when single-phase grounding occurs in system with neutral-point solid grounding using physical conception. Then, RTDS model is built incorporating parameters of actual system to verify the accuracy and validity of the analysis model with complete electrical parameters using real-time simulation. In conclusion, amplitude and phase of non-fault phase is influenced by load condition, position of fault, system impedance, line impedance, etc., which offer favorable references for judging grid fault characteristics and positioning of fault in a fast and effective way.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Fault location of a small current grounding fault based on distribution characteristics of zero sequence voltage
    Liu J.
    Dong L.
    Xue C.
    Xue Y.
    Li J.
    Chen Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (03): : 59 - 67
  • [22] Simulation of single-phase grounding fault on non-grounding neutral power system and new conclusions
    Southwest Jiaotong University, Chengdu 610031, China
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2006, 2 (33-36):
  • [23] Grounding fault location of transmission line by traveling wave differential current
    Xuan W.
    Zhang Y.
    Chen X.
    Xu L.
    Song W.
    Zhang G.
    Zhang, Yanxia (zyx1962@tju.edu.cn), 2016, Tianjin University (49): : 639 - 645
  • [24] Analysis on current characteristics of PMSG under grid three-phase fault
    Chang, Zhongxue
    Song, Guobing
    Wang, Ting
    JOURNAL OF ENGINEERING-JOE, 2018, (15): : 785 - 790
  • [25] Residual current compensation for single-phase grounding fault in coal mine power network
    Jia Chenxi
    Wang Chonglin
    Du Guifu
    INTERNATIONAL JOURNAL OF MINING SCIENCE AND TECHNOLOGY, 2014, 24 (02) : 213 - 218
  • [26] Residual current compensation for single-phase grounding fault in coal mine power network
    Jia Chenxi
    Wang Chonglin
    Du Guifu
    International Journal of Mining Science and Technology, 2014, 24 (02) : 213 - 218
  • [27] Analysis on Fault Current Suppression Characteristics of Flexible DC Power Grid with Current Flow Controller
    Zhou N.
    Xiang H.
    Wei N.
    Liao J.
    Wang H.
    Wang Q.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (04): : 142 - 152
  • [28] A New Research on Intelligent Protection and Positioning Integration Method of Single Phase Grounding Fault in Small Current Grounding System
    Cao Jingjin
    Qin Lijun
    Li Yongxiang
    Jin Tao
    Yuan Hui
    Zhang Zhengyu
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [29] Research on fault current limitation and active control for power electronic transformer in direct current grid
    Zhuo, Chaoran
    Zhang, Xiaotian
    Zhang, Xiong
    Yang, Xu
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2021, 15 (01) : 121 - 134
  • [30] Novel algorithm for fault diagnosis of grounding grid
    He, Zhi-Qiang
    Wen, Xi-Shan
    Pan, Zhuo-Hong
    Lu, Hai-Liang
    Zhang, Ke
    Wang, Jian-Wu
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (04): : 83 - 86