Nano-rheology of hydrogels using direct drive force modulation atomic force microscopy

被引:72
|
作者
Nalam, Prathima C. [1 ]
Gosvami, Nitya N. [1 ]
Caporizzo, Matthew A. [2 ]
Composto, Russell J. [2 ]
Carpick, Robert W. [1 ,2 ]
机构
[1] Univ Penn, Dept Mech Engn & Appl Mech, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Mat Sci & Engn, Philadelphia, PA 19104 USA
基金
美国国家科学基金会; 瑞士国家科学基金会;
关键词
MECHANICAL-PROPERTIES; EXTRACELLULAR-MATRIX; POLYMER GELS; CELLS; VISCOELASTICITY; MICRORHEOLOGY; CARTILAGE; TISSUE; ELASTICITY; ADHESION;
D O I
10.1039/c5sm01143d
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We present a magnetic force-based direct drive modulation method to measure local nano-rheological properties of soft materials across a broad frequency range (10 Hz to 2 kHz) using colloid-attached atomic force microscope (AFM) probes in liquid. The direct drive method enables artefact-free measurements over several decades of excitation frequency, and avoids the need to evaluate medium-induced hydrodynamic drag effects. The method was applied to measure the local mechanical properties of polyacrylamide hydrogels. The frequency-dependent storage stiffness, loss stiffness, and loss tangent (tan d) were quantified for hydrogels having high and low crosslinking densities by measuring the amplitude and the phase response of the cantilever while the colloid was in contact with the hydrogel. The frequency bandwidth was further expanded to lower effective frequencies (0.1 Hz to 10 Hz) by obtaining force-displacement (FD) curves. Slow FD measurements showed a recoverable but highly hysteretic response, with the contact mechanical behaviour dependent on the loading direction: approach curves showed Hertzian behaviour while retraction curves fit the JKR contact mechanics model well into the adhesive regime, after which multiple detachment instabilities occurred. Using small amplitude dynamic modulation to explore faster rates, the load dependence of the storage stiffness transitioned from Hertzian to a dynamic punch-type (constant contact area) model, indicating significant influence of material dissipation coupled with adhesion. Using the appropriate contact model across the full frequency range measured, the storage moduli were found to remain nearly constant until an increase began near similar to 100 Hz. The softer gels' storage modulus increased from 7.9 +/- 0.4 to 14.5 +/- 2.1 kPa (similar to 85%), and the stiffer gels' storage modulus increased from 16.3 +/- 1.1 to 31.7 +/- 5.0 kPa (similar to 95%). This increase at high frequencies may be attributed to a contribution from solvent confinement in the hydrogel (poroelasticity). The storage moduli measured by both macrorheometry and AFM FD curves were comparable to those measured using the modulation method at their overlapping frequencies (10-25 Hz). In all cases, care was taken to ensure the contact mechanics models were applied within the important limit of small relative deformations. This study thus highlights possible transitions in the probe-material contact mechanical behaviour for soft matter, especially when the applied strain rates and the material relaxation rates become comparable. In particular, at low frequencies, the modulus follows Hertzian contact mechanics, while at high frequencies adhesive contact is well represented by punch-like behaviour. More generally, use of the Hertz model on hydrogels at high loading rates, at high strains, or during the retraction portion of FD curves, leads to significant errors in the calculated moduli.
引用
收藏
页码:8165 / 8178
页数:14
相关论文
共 50 条
  • [31] Atomic force microscopy and lateral force microscopy using piezoresistive cantilevers
    Linnemann, R
    Gotszalk, T
    Rangelow, IW
    Dumania, P
    Oesterschulze, E
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (02): : 856 - 860
  • [32] Atomic force microscopy and lateral force microscopy using piezoresistive cantilevers
    Linnemann, R.
    Gotszalk, T.
    Rangelow, I.W.
    Dumania, P.
    Oesterschulze, E.
    Journal of Vacuum Science & Technology B: Microelectronics Processing and Phenomena, 1996, 14 (02):
  • [33] Mapping cell-to-cell variations in power-law rheology investigated by multifrequency force modulation atomic force microscopy
    Sawano, M.
    Tanaka, R.
    Takahashi, R.
    Kurubayashi-Shigetomi, K.
    Subagyo, A.
    Sueoka, K.
    Okajima, T.
    MOLECULAR BIOLOGY OF THE CELL, 2016, 27
  • [34] Corrected direct force balance method for atomic force microscopy lateral force calibration
    Asay, David B.
    Hsiao, Erik
    Kim, Seong H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (06):
  • [35] Nano-mechanical methods in biochemistry using atomic force microscopy
    Ikai, A
    Afrin, R
    Sekiguchi, H
    Okajima, T
    Alam, MT
    Nishida, S
    CURRENT PROTEIN & PEPTIDE SCIENCE, 2003, 4 (03) : 181 - 193
  • [36] Quantitative Nano-characterization of Polymers Using Atomic Force Microscopy
    Radiom, Milad
    Kozhuharov, Svilen
    Kong, Phally
    di Giannantonio, Michela
    Ayer, Mathieu A.
    Maroni, Plinio
    Kilbinger, Andreas F. M.
    Fromm, Katharina M.
    Weder, Christoph
    Borkovec, Michal
    CHIMIA, 2017, 71 (04) : 195 - 198
  • [37] Direct force measurements at polymer brush surfaces by atomic force microscopy
    Kelley, TW
    Schorr, PA
    Johnson, KD
    Tirrell, M
    Frisbie, CD
    MACROMOLECULES, 1998, 31 (13) : 4297 - 4300
  • [38] Direct force measurement of single DNA-peptide interactions using atomic force microscopy
    Chung, Ji W.
    Shin, Dongjin
    Kwak, June M.
    Seog, Joonil
    JOURNAL OF MOLECULAR RECOGNITION, 2013, 26 (06) : 268 - 275
  • [39] Direct force measurement between cucurbit[6]uril and spermine using atomic force microscopy
    Kim, Jeonghan
    Kim, Youngkook
    Baek, Kangkyun
    Ko, Young Ho
    Kim, Dongwoo
    Kim, Kimoon
    TETRAHEDRON, 2008, 64 (36) : 8389 - 8393
  • [40] Time fluctuation of single cell rheology by atomic force microscopy
    Cai, P.
    Mizutani, Y.
    Tsuchiya, M.
    Okajima, T.
    MOLECULAR BIOLOGY OF THE CELL, 2011, 22