Nano-rheology of hydrogels using direct drive force modulation atomic force microscopy

被引:72
|
作者
Nalam, Prathima C. [1 ]
Gosvami, Nitya N. [1 ]
Caporizzo, Matthew A. [2 ]
Composto, Russell J. [2 ]
Carpick, Robert W. [1 ,2 ]
机构
[1] Univ Penn, Dept Mech Engn & Appl Mech, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Mat Sci & Engn, Philadelphia, PA 19104 USA
基金
美国国家科学基金会; 瑞士国家科学基金会;
关键词
MECHANICAL-PROPERTIES; EXTRACELLULAR-MATRIX; POLYMER GELS; CELLS; VISCOELASTICITY; MICRORHEOLOGY; CARTILAGE; TISSUE; ELASTICITY; ADHESION;
D O I
10.1039/c5sm01143d
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We present a magnetic force-based direct drive modulation method to measure local nano-rheological properties of soft materials across a broad frequency range (10 Hz to 2 kHz) using colloid-attached atomic force microscope (AFM) probes in liquid. The direct drive method enables artefact-free measurements over several decades of excitation frequency, and avoids the need to evaluate medium-induced hydrodynamic drag effects. The method was applied to measure the local mechanical properties of polyacrylamide hydrogels. The frequency-dependent storage stiffness, loss stiffness, and loss tangent (tan d) were quantified for hydrogels having high and low crosslinking densities by measuring the amplitude and the phase response of the cantilever while the colloid was in contact with the hydrogel. The frequency bandwidth was further expanded to lower effective frequencies (0.1 Hz to 10 Hz) by obtaining force-displacement (FD) curves. Slow FD measurements showed a recoverable but highly hysteretic response, with the contact mechanical behaviour dependent on the loading direction: approach curves showed Hertzian behaviour while retraction curves fit the JKR contact mechanics model well into the adhesive regime, after which multiple detachment instabilities occurred. Using small amplitude dynamic modulation to explore faster rates, the load dependence of the storage stiffness transitioned from Hertzian to a dynamic punch-type (constant contact area) model, indicating significant influence of material dissipation coupled with adhesion. Using the appropriate contact model across the full frequency range measured, the storage moduli were found to remain nearly constant until an increase began near similar to 100 Hz. The softer gels' storage modulus increased from 7.9 +/- 0.4 to 14.5 +/- 2.1 kPa (similar to 85%), and the stiffer gels' storage modulus increased from 16.3 +/- 1.1 to 31.7 +/- 5.0 kPa (similar to 95%). This increase at high frequencies may be attributed to a contribution from solvent confinement in the hydrogel (poroelasticity). The storage moduli measured by both macrorheometry and AFM FD curves were comparable to those measured using the modulation method at their overlapping frequencies (10-25 Hz). In all cases, care was taken to ensure the contact mechanics models were applied within the important limit of small relative deformations. This study thus highlights possible transitions in the probe-material contact mechanical behaviour for soft matter, especially when the applied strain rates and the material relaxation rates become comparable. In particular, at low frequencies, the modulus follows Hertzian contact mechanics, while at high frequencies adhesive contact is well represented by punch-like behaviour. More generally, use of the Hertz model on hydrogels at high loading rates, at high strains, or during the retraction portion of FD curves, leads to significant errors in the calculated moduli.
引用
收藏
页码:8165 / 8178
页数:14
相关论文
共 50 条
  • [21] Nanomechanical measurements of polyethylene glycol hydrogels using atomic force microscopy
    Drira, Zouheir
    Yadavalli, Vamsi K.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 18 : 20 - 28
  • [22] Direct force balance method for atomic force microscopy lateral force calibration
    Asay, DB
    Kim, SH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (04):
  • [23] Nano-writing with atomic force microscopy
    Crossley, A
    Mapledoram, L
    Sofield, C
    Johnston, C
    Myhra, S
    MICRO MATERIALS, PROCEEDINGS, 2000, : 683 - 688
  • [24] Rheology of polymer solutions using colloidal-probe atomic force microscopy
    Darwiche, A.
    Ingremeau, F.
    Amarouchene, Y.
    Maali, A.
    Dufour, I.
    Kellay, H.
    PHYSICAL REVIEW E, 2013, 87 (06):
  • [25] Modelling and nanoscale force spectroscopy of frequency modulation atomic force microscopy
    Payam, Amir Farokh
    APPLIED MATHEMATICAL MODELLING, 2020, 79 (79) : 544 - 554
  • [26] Force modulation atomic force microscopy recording for ultrahigh density recording
    Hitachi Ltd, Tokyo, Japan
    J Vac Sci Technol B, 4 (788-792):
  • [27] Force modulation atomic force microscopy recording for ultrahigh density recording
    Hosaka, S
    Koyanagi, H
    Kikukawa, A
    Miyamoto, M
    Nakamura, K
    Etoh, K
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1997, 15 (04): : 788 - 792
  • [28] Measuring the size dependence of Young's modulus using force modulation atomic force microscopy
    Price, WJ
    Leigh, SA
    Hsu, SM
    Patten, TE
    Liu, GY
    JOURNAL OF PHYSICAL CHEMISTRY A, 2006, 110 (04): : 1382 - 1388
  • [29] Rupture force determination using atomic force microscopy
    Costello, Erica
    Akaygun, Sevil
    Pacheco, Kimberly A. O.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 237 : 300 - 300
  • [30] Elastic properties of living fibroblasts as imaged using force modulation mode in atomic force microscopy
    Sasaki, S
    Morimoto, M
    Haga, H
    Kawabata, K
    Ito, E
    Ushiki, T
    Abe, K
    Sambongi, T
    ARCHIVES OF HISTOLOGY AND CYTOLOGY, 1998, 61 (01) : 57 - 63