Optimization of hydrogen mitigation systems in CPR1000 during a refueling outage

被引:4
|
作者
Huang, Zhi'ao [1 ]
Miao, Huifang [1 ]
Zheng, Chenxi [1 ]
Li, Ning [1 ]
Shi, Xingwei [2 ]
Lei, Lei [2 ]
机构
[1] Xiamen Univ, Coll Energy, 4221-104 Xiangan South Rd, Xiamen 361002, Peoples R China
[2] Minist Ecol & Environm Peoples Republ China, Nucl & Radiat Safety Ctr, 54 Hongliannan Village, Beijing 100000, Peoples R China
关键词
Hydrogen risk; PAR system; Refueling outage; CPR1000; MELCOR; CONTAINMENT; RISK;
D O I
10.1016/j.anucene.2019.02.013
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This study deals with the identification of hydrogen risk and optimization of current hydrogen mitigation systems in the CPR1000 nuclear power plant (NPP) during a refueling outage. A detailed MELCOR input is developed, which includes detailed containment nodalization, accurate configuration of the passive autocatalytic recombiner (PAR) systems, and realistic boundary conditions based on design data and technical specifications. Two cases that represent different plant operation states (POS) and specific hydrogen release paths are selected, and the accident progression and hydrogen risk are analyzed subsequently. The analysis indicates that the hydrogen risk is still of great importance during a refueling outage, although the accident progression is relatively slow. PAR systems with the current configuration are added to the plant model to verify the effectiveness of the hydrogen mitigation system in the CPR1000 during a refueling outage. The results indicate that the current configuration of PAR systems is still effective in mitigating the hydrogen risk during an accident in POS E but is insufficient in mitigating the hydrogen risk during an accident in POS H. Therefore, two strategies to improve the hydrogen mitigation systems are proposed, and their effectiveness is compared. It is concluded that mobile ignitors should be employed in the refueling pool region to avoid severe hydrogen risk during a refueling outage. The results of this study can support the development of the low power and shutdown (LPSD) probabilistic safety assessment (PSA) model and improve the capacity of NPPs to reduce the hydrogen risk during a refueling outage. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:253 / 263
页数:11
相关论文
共 21 条
  • [1] Analysis of hydrogen risk and its mitigation systems in CPR1000 during shutdown conditions
    Huang, Zhi'ao
    Miao, Huifang
    Li, Ning
    Shi, Xingwei
    Lei, Lei
    [J]. PROGRESS IN NUCLEAR ENERGY, 2019, 115 : 194 - 207
  • [2] Effect of spray on performance of the hydrogen mitigation system during LB-LOCA for CPR1000 NPP
    Huang, X. G.
    Yang, Y. H.
    Cheng, X.
    Al-Hawshabi, N. H. A.
    Casey, S. P.
    [J]. ANNALS OF NUCLEAR ENERGY, 2011, 38 (08) : 1743 - 1750
  • [3] Analysis of hydrogen risk mitigation with passive autocatalytic recombiner system in CPR1000 NPP during a hypothetical station blackout
    Huang, X. G.
    Yang, Y. H.
    Zhang, S. X.
    [J]. ANNALS OF NUCLEAR ENERGY, 2011, 38 (12) : 2762 - 2769
  • [4] Optimization of Power Ramp Rate in CPR1000 Reactor Restarting
    Li, Changzheng
    Lin, Shaofang
    Liu, Weichao
    Cai, Zhiyi
    Nie, Lihong
    Deng, Yongjun
    [J]. Hedongli Gongcheng/Nuclear Power Engineering, 2019, 40 (05): : 74 - 78
  • [5] Research on Severe Accident Management Strategies for CPR1000 NPP Under Refueling Cooling Mode
    Jiang, Pingting
    He, Dongyu
    Hua, Xi
    Peng, Zhenxun
    Zhang, Juanhua
    [J]. PROCEEDINGS OF THE 20TH PACIFIC BASIN NUCLEAR CONFERENCE, VOL 1, 2017, : 525 - 534
  • [6] Comparison of CPR1000 and AP1000 rod position indication systems
    Lei, Qing
    [J]. Hedongli Gongcheng/Nuclear Power Engineering, 2009, 30 (SUPPL. 2): : 45 - 48
  • [7] STUDY ON TECHNICAL SCHEME AND FRAME OF EXTREME HAZARDS MITIGATION GUIDELINE FOR CPR1000 NPP
    Zhang, Juanhua
    Zhai, Shouyang
    Liao, YeHong
    [J]. PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 7, 2017,
  • [8] Optimization of CPR1000 Charging Pump Shaft Power and Hydraulic Performance Study
    Zhang, Qiangsheng
    Ma, Huiping
    Wang, Yan
    Shen, Wei
    Wu, Chao
    [J]. Hedongli Gongcheng/Nuclear Power Engineering, 2019, 40 (03): : 134 - 137
  • [9] Application of FMEA Technology in CCM Equipment Maintenance Optimization of CPR1000 Unit
    Yang, Lifei
    Wu, Tao
    Qing, Chen
    Liu, Xiaolei
    Shi, Lei
    [J]. Hedongli Gongcheng/Nuclear Power Engineering, 2019, 40 (05): : 175 - 179
  • [10] Primary coolant drainage level response analysis and optimization of CPR1000 units
    Chen, Yongwei
    You, Dailun
    Li, Dong
    Xie, Yongjing
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2018, 327 : 1 - 6