Magnitude and Direction of Pulsatile Displacement Forces Acting on Thoracic Aortic Endografts

被引:74
|
作者
Figueroa, C. Alberto [2 ]
Taylor, Charles A. [1 ,2 ]
Chiou, Allen J. [2 ]
Yeh, Victoria [2 ]
Zarins, Christopher K. [1 ]
机构
[1] Stanford Univ, Med Ctr, Dept Surg, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
关键词
displacement forces; aortic endografts; endograft migration; thoracic aortic aneurysm; angulation and curvature; computational fluid dynamics; ENDOVASCULAR STENT-GRAFTS; BLOOD-FLOW; ANEURYSM SAC; ARTERIES; REPAIR; MOVEMENT; PRESSURE; FIXATION; TRIAL;
D O I
10.1583/09-2738.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To assess 3-dimensional (3D) pulsatile displacement forces (DF) acting on thoracic endografts using 3D computational techniques. Methods: A novel computational method to quantitate the pulsatile 3D flow and pressure fields and aortic wall dynamics in patient-specific anatomical models based on cardiac-gated computed tomography (CT) scans was used to construct simulations of the proximal and mid-descending thoracic aorta. Endografts of varying lengths and diameters were implanted in these patient-specific models. The magnitude and direction of the DF vector were calculated and expressed in Newtons (N). This DF included the effects of both the pressure and shearing stresses of blood. Results: The magnitude of DF increased with endografts of increasing diameter and length. A 36-mm endograft in the mid-descending aorta had a mean DF of 21.7 N with a peak systolic DF of 27.8 N and an end-diastolic DF of 16.7 N. Conversely, a 30-mm endograft in the proximal descending aorta had a mean DF of 14.9 N, with peak systolic and end-diastolic DFs of 18.9 and 11.5, respectively. The orientation of the DF acting on the endograft varied depending on aortic angulation and tortuosity; in general, the vector was perpendicular to the greater curvature of the endograft rather than along the downstream longitudinal centerline axis of the aorta as is commonly believed. The DF vector pointed primarily in the cranial direction for the proximal descending endograft and in the sideways direction for the mid-descending endograft simulation. Furthermore, it was shown that elevated pressure plays an important role in the magnitude and direction of DF; an increase in mean blood pressure resulted in an approximately linearly proportional increase in DF. Conclusion: The orientation of the DF varies depending on curvature and location of the endograft, but in all instances, it is in the cranial rather than caudal direction on axial imaging. This is counter to the intuitive notion that displacement forces act in the downward direction of blood flow. Therefore, we postulate that migration of thoracic endografts may be different from abdominal endografts since it may involve upward rather than downward movement of the graft. Computational methods can enhance the understanding of the magnitude and orientation of the loads experienced in vivo by thoracic aortic endografts and therefore improve their design and performance. J Endovasc Ther. 2009;16:350-358
引用
收藏
页码:350 / 358
页数:9
相关论文
共 50 条
  • [31] Thoracic aortic endografts used to resect the left subclavian artery infiltrated by malignant tumours
    Sakai, Takashi
    Uehara, Hirofumi
    Imazuru, Tomohiro
    Kawamura, Masafumi
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 55 (06) : 1228 - 1230
  • [32] Use of EndoAnchors to Secure Thoracic and Abdominal Aortic Endografts: Key to Overcoming Apposition Failures?
    de Vries, Jean-Paul P. M.
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (04) : 481 - 483
  • [33] Increased Pulse Wave Velocity and Arterial Hypertension in Young Patients With Thoracic Aortic Endografts
    Tzilalis, Vasileios D.
    Kamvysis, Dimitrios
    Panagou, Panagiotis
    Kaskarelis, Ioannis
    Lazarides, Miltos K.
    Perdikides, Theodossios
    Prassopoulos, Panagiotis
    Boudoulas, Harisios
    ANNALS OF VASCULAR SURGERY, 2012, 26 (04) : 462 - 467
  • [34] Analysis of forces acting upon submacular hemorrhage in pneumatic displacement
    Stopa, Marcin
    Lincoff, Andrew
    Lincoff, Harvey
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2007, 27 (03): : 370 - 374
  • [35] MAGNITUDE OF FORCES ACTING ON THE PROXIMAL FEMUR IN DIFFERENT RELIEVING GAITS WITH REDUCED GROUND REACTION FORCES
    SAVVIDIS, E
    LOER, F
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1989, 127 (01): : 111 - 117
  • [36] A New Methodology to Determine Apposition, Dilatation, and Position of Endografts in the Descending Thoracic Aorta After Thoracic Endovascular Aortic Repair
    van Noort, Kim
    Schuurmann, Richte C. L.
    Hospers, Gersom Post
    van der Weijde, Emma
    Smeenk, Hans G.
    Heijmen, Robin H.
    de Vries, Jean-Paul P. M.
    JOURNAL OF ENDOVASCULAR THERAPY, 2019, 26 (05) : 679 - 687
  • [37] Thoracic Aortic Aneurysm Growth in Bicuspid Aortic Valve Patients: Role of Aortic Stiffness and Pulsatile Hemodynamics
    Rooprai, Jasjit
    Boodhwani, Munir
    Beauchesne, Luc
    Chan, Kwan-Leung
    Dennie, Carole
    Nagpal, Sudhir
    Messika-Zeitoun, David
    Coutinho, Thais
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (08):
  • [38] Effect of jaw opening on the direction and magnitude of human incisal bite forces
    Paphangkorakit, J
    Osborn, JW
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (01) : 561 - 567
  • [39] Magnitude of the Forces Acting on Target Vessel Stents as a Result of a Mismatch Between Native Aortic Anatomy and Fenestrated Stent-Grafts
    Oshin, Olufemi A.
    How, Thien V.
    Brennan, John A.
    Fisher, Robert K.
    McWilliams, Richard G.
    Vallabhaneni, S. Rao
    JOURNAL OF ENDOVASCULAR THERAPY, 2011, 18 (04) : 569 - 575
  • [40] Comparison of Surgical Debranching Versus Branched Endografts in Zone 2 Thoracic Endovascular Aortic Repair
    Shutze, William P., Sr.
    Baxter, Ronald
    Gable, Cara
    Harrington, Katherine
    Schaffer, Justin
    Moore, David
    Brinkman, William
    Gable, Dennis
    Dimaio, Michael
    JOURNAL OF VASCULAR SURGERY, 2021, 73 (03) : E50 - E52