Magnitude and Direction of Pulsatile Displacement Forces Acting on Thoracic Aortic Endografts

被引:74
|
作者
Figueroa, C. Alberto [2 ]
Taylor, Charles A. [1 ,2 ]
Chiou, Allen J. [2 ]
Yeh, Victoria [2 ]
Zarins, Christopher K. [1 ]
机构
[1] Stanford Univ, Med Ctr, Dept Surg, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
关键词
displacement forces; aortic endografts; endograft migration; thoracic aortic aneurysm; angulation and curvature; computational fluid dynamics; ENDOVASCULAR STENT-GRAFTS; BLOOD-FLOW; ANEURYSM SAC; ARTERIES; REPAIR; MOVEMENT; PRESSURE; FIXATION; TRIAL;
D O I
10.1583/09-2738.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To assess 3-dimensional (3D) pulsatile displacement forces (DF) acting on thoracic endografts using 3D computational techniques. Methods: A novel computational method to quantitate the pulsatile 3D flow and pressure fields and aortic wall dynamics in patient-specific anatomical models based on cardiac-gated computed tomography (CT) scans was used to construct simulations of the proximal and mid-descending thoracic aorta. Endografts of varying lengths and diameters were implanted in these patient-specific models. The magnitude and direction of the DF vector were calculated and expressed in Newtons (N). This DF included the effects of both the pressure and shearing stresses of blood. Results: The magnitude of DF increased with endografts of increasing diameter and length. A 36-mm endograft in the mid-descending aorta had a mean DF of 21.7 N with a peak systolic DF of 27.8 N and an end-diastolic DF of 16.7 N. Conversely, a 30-mm endograft in the proximal descending aorta had a mean DF of 14.9 N, with peak systolic and end-diastolic DFs of 18.9 and 11.5, respectively. The orientation of the DF acting on the endograft varied depending on aortic angulation and tortuosity; in general, the vector was perpendicular to the greater curvature of the endograft rather than along the downstream longitudinal centerline axis of the aorta as is commonly believed. The DF vector pointed primarily in the cranial direction for the proximal descending endograft and in the sideways direction for the mid-descending endograft simulation. Furthermore, it was shown that elevated pressure plays an important role in the magnitude and direction of DF; an increase in mean blood pressure resulted in an approximately linearly proportional increase in DF. Conclusion: The orientation of the DF varies depending on curvature and location of the endograft, but in all instances, it is in the cranial rather than caudal direction on axial imaging. This is counter to the intuitive notion that displacement forces act in the downward direction of blood flow. Therefore, we postulate that migration of thoracic endografts may be different from abdominal endografts since it may involve upward rather than downward movement of the graft. Computational methods can enhance the understanding of the magnitude and orientation of the loads experienced in vivo by thoracic aortic endografts and therefore improve their design and performance. J Endovasc Ther. 2009;16:350-358
引用
收藏
页码:350 / 358
页数:9
相关论文
共 50 条
  • [21] Computational Fluid Dynamics in Descending Thoracic Aortic Aneurysm: Tortuosity Associated With High Displacement Forces
    Belvroy, Viony M.
    Romarowski, Rodrigo R.
    van Herwaarden, Joost A.
    Bismuth, Jean
    Auricchio, Ferdinando
    Moll, Frans L.
    Trimarchi, Santi
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (03) : E34 - E34
  • [22] Regression of a descending thoracoabdominal aortic dissection following staged deployment of thoracic and abdominal aortic endografts
    White, RA
    Donayre, C
    Walot, I
    Lee, J
    Kopchok, GE
    JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 : 92 - 97
  • [23] Modification of Thoracic Endografts to Treat latrogenic Type A Aortic Dissection: A Case Report
    Hsu, Hung-Lung
    Chen, Jer-Shen
    Chiu, Kuan-Ming
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 29 (05) : 740 - 742
  • [24] Outcomes of total percutaneous endovascular aortic repair for thoracic, fenestrated, and branched endografts
    de Souza, Leonardo R.
    Oderich, Gustavo S.
    Banga, Peter V.
    Hofer, Janet M.
    Wigham, Jean R.
    Cha, Stephen
    Gloviczki, Peter
    JOURNAL OF VASCULAR SURGERY, 2015, 62 (06) : 1442 - +
  • [25] Magnetic resonance imaging versus multislice computed tomography of thoracic aortic endografts
    Merkle, EM
    Klein, S
    Wisianowsky, C
    Boll, DT
    Fleiter, TR
    Pamler, R
    Görich, J
    Brambs, HJ
    JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 : 2 - 3
  • [26] Pullout Forces for Modular Components of Physician-Modified Thoracoabdominal Aortic Endografts
    Koopmann, Matthew C.
    Kopchok, George E.
    Nemceff, Dennis
    Donayre, Carlos E.
    White, Rodney A.
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (06) : 105S - 105S
  • [27] Endografts for the treatment of descending thoracic aortic aneurysm: Results of the first 150 procedures
    Dake, M
    Semba, C
    Kee, S
    Razavi, M
    Slonim, S
    Samuels, S
    Sze, D
    Mitchell, R
    Miller, D
    JOURNAL OF ENDOVASCULAR SURGERY, 1999, 6 (02): : 189 - 189
  • [28] FORCES ACTING IN THE DIRECTION OF PROPAGATION IN PULSED ULTRASOUND FIELDS
    STARRITT, HC
    DUCK, FA
    HUMPHREY, VF
    PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (11): : 1465 - 1474
  • [29] Pulsatile thoracic mass after transcatheter aortic valve implantation
    Fabregat-Andres, Oscar
    Estornell-Erill, Jordi
    Bochard, Bruno
    Canovas, Sergio
    Morell, Salvador
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (03) : 275 - 275
  • [30] A Computational Study of the Magnitude and Direction of Migration Forces in Patient-specific Abdominal Aortic Aneurysm Stent-Grafts
    Molony, D. S.
    Kavanagh, E. G.
    Madhavan, P.
    Walsh, M. T.
    McGloughlin, T. M.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2010, 40 (03) : 332 - 339