Magnitude and Direction of Pulsatile Displacement Forces Acting on Thoracic Aortic Endografts

被引:74
|
作者
Figueroa, C. Alberto [2 ]
Taylor, Charles A. [1 ,2 ]
Chiou, Allen J. [2 ]
Yeh, Victoria [2 ]
Zarins, Christopher K. [1 ]
机构
[1] Stanford Univ, Med Ctr, Dept Surg, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
关键词
displacement forces; aortic endografts; endograft migration; thoracic aortic aneurysm; angulation and curvature; computational fluid dynamics; ENDOVASCULAR STENT-GRAFTS; BLOOD-FLOW; ANEURYSM SAC; ARTERIES; REPAIR; MOVEMENT; PRESSURE; FIXATION; TRIAL;
D O I
10.1583/09-2738.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To assess 3-dimensional (3D) pulsatile displacement forces (DF) acting on thoracic endografts using 3D computational techniques. Methods: A novel computational method to quantitate the pulsatile 3D flow and pressure fields and aortic wall dynamics in patient-specific anatomical models based on cardiac-gated computed tomography (CT) scans was used to construct simulations of the proximal and mid-descending thoracic aorta. Endografts of varying lengths and diameters were implanted in these patient-specific models. The magnitude and direction of the DF vector were calculated and expressed in Newtons (N). This DF included the effects of both the pressure and shearing stresses of blood. Results: The magnitude of DF increased with endografts of increasing diameter and length. A 36-mm endograft in the mid-descending aorta had a mean DF of 21.7 N with a peak systolic DF of 27.8 N and an end-diastolic DF of 16.7 N. Conversely, a 30-mm endograft in the proximal descending aorta had a mean DF of 14.9 N, with peak systolic and end-diastolic DFs of 18.9 and 11.5, respectively. The orientation of the DF acting on the endograft varied depending on aortic angulation and tortuosity; in general, the vector was perpendicular to the greater curvature of the endograft rather than along the downstream longitudinal centerline axis of the aorta as is commonly believed. The DF vector pointed primarily in the cranial direction for the proximal descending endograft and in the sideways direction for the mid-descending endograft simulation. Furthermore, it was shown that elevated pressure plays an important role in the magnitude and direction of DF; an increase in mean blood pressure resulted in an approximately linearly proportional increase in DF. Conclusion: The orientation of the DF varies depending on curvature and location of the endograft, but in all instances, it is in the cranial rather than caudal direction on axial imaging. This is counter to the intuitive notion that displacement forces act in the downward direction of blood flow. Therefore, we postulate that migration of thoracic endografts may be different from abdominal endografts since it may involve upward rather than downward movement of the graft. Computational methods can enhance the understanding of the magnitude and orientation of the loads experienced in vivo by thoracic aortic endografts and therefore improve their design and performance. J Endovasc Ther. 2009;16:350-358
引用
收藏
页码:350 / 358
页数:9
相关论文
共 50 条
  • [1] Effect of Curvature on Displacement Forces Acting on Aortic Endografts: A 3-Dimensional Computational Analysis
    Figueroa, C. Alberto
    Taylor, Charles A.
    Yeh, Victoria
    Chiou, Allen J.
    Zarins, Christopher K.
    JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (03) : 284 - 294
  • [2] Computational Analysis of Stresses Acting on Intermodular Junctions in Thoracic Aortic Endografts
    Prasad, Anamika
    To, Lillian K.
    Gorrepati, Madhu L.
    Zarins, Christopher K.
    Figueroa, C. Alberto
    JOURNAL OF ENDOVASCULAR THERAPY, 2011, 18 (04) : 559 - 568
  • [3] Impact of Aortic Tortuosity on Displacement Forces in Descending Thoracic Aortic Aneurysms
    Belvroy, Viony M.
    Romarowski, Rodrigo M.
    van Bakel, Theodorus M. J.
    van Herwaarden, Joost A.
    Bismuth, Jean
    Auricchio, Ferdinando
    Moll, Frans L.
    Trimarchi, Santi
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 59 (04) : 557 - 564
  • [4] Thoracic Aortic Endografts: Past, Present, and Future
    Kumar, Shivani
    Choinski, Krystina N.
    Tadros, Rami O.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 37
  • [5] Secondary Infections of Thoracic and Abdominal Aortic Endografts
    Heyer, Karnaldeep S.
    Modi, Parth
    Morasch, Mark D.
    Matsumura, Jon S.
    Kibbe, Melina R.
    Pearce, William H.
    Resnick, Scott A.
    Eskandari, Mark K.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (02) : 173 - 179
  • [6] Advanced thoracic endovascular aortic repair: Late complications of thoracic endografts
    Halandras, Pegge
    Milner, Ross
    JOURNAL OF VASCULAR SURGERY, 2010, 52 : 100S - 102S
  • [7] Analysis and Quantification of Retained Air in Thoracic Aortic Endografts
    Gagnon, Joel
    Tittley, Jacques
    Misskey, Jonathan D.
    JOURNAL OF VASCULAR SURGERY, 2017, 65 (06) : 73S - 73S
  • [8] DIRECTION, MAGNITUDE AND CAUSES OF PHOTOPHORETIC FORCES
    ROHATSCHEK, H
    JOURNAL OF AEROSOL SCIENCE, 1985, 16 (01) : 29 - 42
  • [9] Computer modelling of maximal displacement forces in endoluminal thoracic aortic stent graft
    Krsmanovic, Dejan
    Koncar, Igor
    Petrovic, Dejan
    Milasinovic, Danko
    Davidovic, Lazar
    Filipovic, Nenad
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 (09) : 1012 - 1020
  • [10] Complications of thoracic aortic endografts: Spinal cord ischemia and stroke
    Sullivan, TM
    Sundt, TM
    JOURNAL OF VASCULAR SURGERY, 2006, 43 : 85A - 88A