Range and dose verification in proton therapy using proton-induced positron emitters and recurrent neural networks (RNNs)

被引:27
|
作者
Liu, Chuang [1 ]
Li, Zhongxing [1 ]
Hu, Wenbin [2 ]
Xing, Lei [3 ]
Peng, Hao [1 ,3 ,4 ]
机构
[1] Wuhan Univ, Dept Med Phys, Wuhan 430072, Hubei, Peoples R China
[2] Wuhan Univ, Dept Comp Sci, Wuhan 430072, Hubei, Peoples R China
[3] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[4] Hokkaido Univ, Global Inst Collaborat Res & Educ GI CoRE, Sapporo, Hokkaido, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 17期
关键词
proton therapy; positron emitter; range verification; dose verification; recurrent neural networks; IN-BEAM PET; PROMPT-GAMMA; VIVO VERIFICATION; PATIENT; SYSTEM; DISTRIBUTIONS; SIMULATION; DELIVERY; CAMERA; YIELDS;
D O I
10.1088/1361-6560/ab3564
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Online proton range/dose verification based on measurements of proton-induced positron emitters is a promising strategy for quality assurance in proton therapy. Because of the nonlinear correlation between the dose distribution and the activity distribution of positron emitters, we aim to establish their relationship using recurrent neural network models (LSTM, BiLSTM, GRU, BiGRU and Seq2seq). Simulations were carried out with a spot-scanning proton system using Geant4- 10.3 toolkit and a CT-based patient phantom. The 1D distributions of positron emitters and radiation dose were obtained. Training data were modeled for different beam energy, irradiation positions and counting statistics. The prediction accuracy of range and dose were quantitatively studied. The impact of including anatomical information (HU values in CT images) on the prediction performance was investigated. The BiGRU demonstrates the most stable and accurate performance with good capability of generalization, especially with the inclusion of anatomical information. When the signal-to-noise ratio (SNR) of the 1 D activity profiles is about 3, the range accuracy can be within 0.5 mm and the dose accuracy close to the peak region is <5% (relative uncertainty between prediction and raw input for all datasets). The feasibility of proton range and dose verification using the RNN-based framework was demonstrated. The RNN-based framework promises to provide a reliable and effective way for online monitoring, quality assurance and ultimately allows for adaptive proton therapy.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] An Analytical Framework for Range Verification in Proton Therapy Using Proton-Induced Positron Emitters and Collimators
    Li, Z.
    Peng, H.
    MEDICAL PHYSICS, 2019, 46 (06) : E268 - E268
  • [2] Technical Note: Machine learning approaches for range and dose verification in proton therapy using proton-induced positron emitters
    Li, Zhongxing
    Wang, Yiang
    Yu, Yajun
    Fan, Kuanjun
    Xing, Lei
    Peng, Hao
    MEDICAL PHYSICS, 2019, 46 (12) : 5748 - 5757
  • [3] Machine Learning-Based Range and Dose Verification in Proton Therapy Using Proton-Induced Positron Emitters and Positron Emission Tomography (PET)
    Li, Z.
    Peng, H.
    MEDICAL PHYSICS, 2019, 46 (06) : E269 - E269
  • [4] Feasibility study of range verification based on proton-induced acoustic signals and recurrent neural network
    Yao, Songhuan
    Hu, Zongsheng
    Zhang, Xiaoke
    Lou, En
    Liang, Zhiwen
    Wang, Yuenan
    Peng, Hao
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (21):
  • [5] Production yields of β+ emitters for range verification in proton therapy
    Rodriguez-Gonzalez, T.
    Guerrero, C.
    Jimenez-Ramos, M. C.
    Dendooven, P.
    Lerendegui-Marco, J.
    Fraile, L. M.
    Millan-Callado, M. A.
    Ozoemelam, I
    Parrado, A.
    Quesada, J. M.
    ND 2019: INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, 2020, 239
  • [6] A machine learning framework with anatomical prior for online dose verification using positron emitters and PET in proton therapy
    Hu, Zongsheng
    Li, Guangyao
    Zhang, Xiaoke
    Ye, Kuangkuang
    Lu, Jiade
    Peng, Hao
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (18):
  • [7] Simulation of proton therapy treatment verification via PET imaging of induced positron-emitters
    Beebe-Wang, J
    Vaska, P
    Dilmanian, FA
    Peggs, SG
    Schlyer, DJ
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2496 - 2500
  • [8] Detectors for in vivo range and dose verification in proton therapy
    Alarcon, R.
    Blyth, D.
    Galyaev, E.
    Holmes, J.
    Ice, L.
    Randall, G.
    Bues, M.
    Fatyga, M.
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLICATIONS OF NUCLEAR TECHNIQUES (CRETE15), 2016, 44
  • [9] Calculation of Positron Emitters' Matrix for Absolute Dose Reconstruction in Proton Therapy
    Fourkal, E.
    Fan, J.
    Ma, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [10] Range verification for eye proton therapy based on proton-induced x-ray emissions from implanted metal markers
    La Rosa, Vanessa
    Kacperek, Andrzej
    Royle, Gary
    Gibson, Adam
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11): : 2623 - 2638