Range verification for eye proton therapy based on proton-induced x-ray emissions from implanted metal markers

被引:3
|
作者
La Rosa, Vanessa [1 ]
Kacperek, Andrzej [2 ]
Royle, Gary [1 ]
Gibson, Adam [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
[2] Clatterbridge Canc Ctr NHS Fdn Trust, Douglas Cyclotron, Wirral CH63 4JT, Merseyside, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 11期
基金
英国工程与自然科学研究理事会;
关键词
proton-therapy; range; markers; eye; PIXE; PROTONTHERAPY; SIMULATION;
D O I
10.1088/0031-9155/59/11/2623
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Metal fiducial markers are often implanted on the back of the eye before proton therapy to improve target localization and reduce patient setup errors. We aim to detect characteristic x-ray emissions from metal targets during proton therapy to verify the treatment range accuracy. Initially gold was chosen for its biocompatibility properties. Proton-induced x-ray emissions (PIXE) from a 15 mm diameter gold marker were detected at different penetration depths of a 59 MeV proton beam at the CATANA proton facility at INFN-LNS (Italy). The Monte Carlo code Geant4 was used to reproduce the experiment and to investigate the effect of different size markers, materials, and the response to both mono-energetic and fully modulated beams. The intensity of the emitted x-rays decreases with decreasing proton energy and thus decreases with depth. If we assume the range to be the depth at which the dose is reduced to 10% of its maximum value and we define the residual range as the distance between the marker and the range of the beam, then the minimum residual range which can be detected with 95% confidence level is the depth at which the PIXE peak is equal to 1.96 sigma(bkg), which is the standard variation of the background noise. With our system and experimental setup this value is 3 mm, when 20 GyE are delivered to a gold marker of 15 mm diameter. Results from silver are more promising. Even when a 5 mm diameter silver marker is placed at a depth equal to the range, the PIXE peak is 2.1 sigma(bkg). Although these quantitative results are dependent on the experimental setup used in this research study, they demonstrate that the real-time analysis of the PIXE emitted by fiducial metal markers can be used to derive beam range. Further analysis are needed to demonstrate the feasibility of the technique in a clinical setup.
引用
收藏
页码:2623 / 2638
页数:16
相关论文
共 50 条
  • [1] PROTON-INDUCED CHARACTERISTIC X-RAY RADIOGRAPHY
    THOMSON, GM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (02) : 1335 - 1338
  • [2] Proton-induced M x-ray production
    Cipolla, SJ
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2001, 576 : 84 - 88
  • [3] Proton-induced x-ray fluorescence CT imaging
    Bazalova-Carter, Magdalena
    Ahmad, Moiz
    Matsuura, Taeko
    Takao, Seishin
    Matsuo, Yuto
    Fahrig, Rebecca
    Shirato, Hiroki
    Umegaki, Kikuo
    Xing, Lei
    MEDICAL PHYSICS, 2015, 42 (02) : 900 - 907
  • [4] X-RAY AND PROTON-INDUCED LENS CHANGES IN RABBIT
    CLEARY, SF
    WILLIAMS, RC
    HAM, WT
    GEERAETS, WJ
    MUELLER, HA
    HEALTH PHYSICS, 1972, 23 (04): : 453 - +
  • [5] An Analytical Framework for Range Verification in Proton Therapy Using Proton-Induced Positron Emitters and Collimators
    Li, Z.
    Peng, H.
    MEDICAL PHYSICS, 2019, 46 (06) : E268 - E268
  • [6] TRACER ANALYSIS OF TUMOR BY PROTON-INDUCED X-RAY SPECTROSCOPY
    ISHII, K
    KAMIYA, M
    SERA, K
    MORITA, S
    CHU, TC
    MATSUZAWA, T
    SHISHIDO, F
    TAWARA, H
    NUCLEAR INSTRUMENTS & METHODS, 1976, 138 (01): : 185 - 189
  • [7] The Columbia University proton-induced soft X-ray microbeam
    Harken, Andrew D.
    Randers-Pehrson, Gerhard
    Johnson, Gary W.
    Brenner, David J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (18): : 1992 - 1996
  • [8] SCANNING PROTON-INDUCED X-RAY MICROSPECTROMETRY IN AN ATMOSPHERIC ENVIRONMENT
    HOROWITZ, P
    GRODZINS, L
    SCIENCE, 1975, 189 (4205) : 795 - 797
  • [9] X-RAY AND PROTON-INDUCED ULTRASTRUCTURAL CHANGES IN CHLAMYDOMONAS REINHARDI
    GRUBER, HE
    RADIATION RESEARCH, 1976, 67 (03) : 565 - 565
  • [10] ALPHA-INDUCED AND PROTON-INDUCED X-RAY DEEXCITATION OF TITANIUM
    RICHARD, P
    SENGLAUB, M
    MOORE, CF
    JOHNSON, B
    APPLIED PHYSICS LETTERS, 1972, 21 (01) : 13 - &