Range and dose verification in proton therapy using proton-induced positron emitters and recurrent neural networks (RNNs)

被引:27
|
作者
Liu, Chuang [1 ]
Li, Zhongxing [1 ]
Hu, Wenbin [2 ]
Xing, Lei [3 ]
Peng, Hao [1 ,3 ,4 ]
机构
[1] Wuhan Univ, Dept Med Phys, Wuhan 430072, Hubei, Peoples R China
[2] Wuhan Univ, Dept Comp Sci, Wuhan 430072, Hubei, Peoples R China
[3] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[4] Hokkaido Univ, Global Inst Collaborat Res & Educ GI CoRE, Sapporo, Hokkaido, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 17期
关键词
proton therapy; positron emitter; range verification; dose verification; recurrent neural networks; IN-BEAM PET; PROMPT-GAMMA; VIVO VERIFICATION; PATIENT; SYSTEM; DISTRIBUTIONS; SIMULATION; DELIVERY; CAMERA; YIELDS;
D O I
10.1088/1361-6560/ab3564
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Online proton range/dose verification based on measurements of proton-induced positron emitters is a promising strategy for quality assurance in proton therapy. Because of the nonlinear correlation between the dose distribution and the activity distribution of positron emitters, we aim to establish their relationship using recurrent neural network models (LSTM, BiLSTM, GRU, BiGRU and Seq2seq). Simulations were carried out with a spot-scanning proton system using Geant4- 10.3 toolkit and a CT-based patient phantom. The 1D distributions of positron emitters and radiation dose were obtained. Training data were modeled for different beam energy, irradiation positions and counting statistics. The prediction accuracy of range and dose were quantitatively studied. The impact of including anatomical information (HU values in CT images) on the prediction performance was investigated. The BiGRU demonstrates the most stable and accurate performance with good capability of generalization, especially with the inclusion of anatomical information. When the signal-to-noise ratio (SNR) of the 1 D activity profiles is about 3, the range accuracy can be within 0.5 mm and the dose accuracy close to the peak region is <5% (relative uncertainty between prediction and raw input for all datasets). The feasibility of proton range and dose verification using the RNN-based framework was demonstrated. The RNN-based framework promises to provide a reliable and effective way for online monitoring, quality assurance and ultimately allows for adaptive proton therapy.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Time Reversal-Based Protoacoustic Reconstruction for Range and Dose Verification in Proton Therapy
    Yu, Y.
    Zhang, D.
    Xing, L.
    Peng, H.
    MEDICAL PHYSICS, 2019, 46 (06) : E366 - E366
  • [22] Three-Dimensional Dose and LETd Prediction in Proton Therapy Using Artificial Neural Networks
    Pirlepesov, F.
    Moskvin, V.
    Wilson, L.
    Breuer, A.
    Merchant, T.
    Faught, A.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [23] Three-dimensional dose and LETD prediction in proton therapy using artificial neural networks
    Pirlepesov, Fakhriddin
    Wilson, Lydia
    Moskvin, Vadim P.
    Breuer, Alex
    Parkins, Franz
    Lucas, John T., Jr.
    Merchant, Thomas E.
    Faught, Austin M.
    MEDICAL PHYSICS, 2022, 49 (12) : 7417 - 7427
  • [24] In Vivo Range Verification Using Single Pulse Proton Induced Acoustic Signals
    Caron, J.
    Gonzalez, G.
    Pandey, P.
    Wang, S.
    Prather, K.
    Xiang, L.
    Ahmad, S.
    Chen, Y.
    MEDICAL PHYSICS, 2022, 49 (06) : E488 - E488
  • [25] Neural Network-Based Range Verification for Proton Therapy Based On Prompt Gamma Emissions
    Peng, H.
    Xing, L.
    MEDICAL PHYSICS, 2017, 44 (06) : 3104 - 3104
  • [26] Neural Network-Based Range Verification for Proton Therapy Based on Prompt Gamma Emissions
    Peng, H.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E711 - E711
  • [27] Use of short-lived positron emitters for in-beam and real-time β+ range monitoring in proton therapy
    Bongrand, A.
    Busato, E.
    Force, P.
    Martin, F.
    Montarou, G.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 : 248 - 255
  • [28] Proton therapy treatment monitoring with the DoPET system: activity range, positron emitters evaluation and comparison with Monte Carlo predictions
    Muraro, S.
    Battistoni, G.
    Belcari, N.
    Bisogni, M. G.
    Camarlinghi, N.
    Cristoforetti, L.
    Del Guerra, A.
    Ferrari, A.
    Fracchiolla, F.
    Morrocchi, M.
    Righetto, R.
    Sala, P.
    Schwarz, M.
    Sportelli, G.
    Topi, A.
    Rosso, V.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [29] Proton Range Shift Verification by Using Gamma Electron Vertex Imaging (GEVI) System in Spot Scanning Proton Therapy
    Kim, S.
    Ku, Y.
    Jung, J.
    Kim, C.
    Jeong, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E167 - E167
  • [30] Adaptive proton therapy using CBCT to calculate daily dose and range variations
    Winey, B.
    Park, Y. K.
    Phillips, J.
    Sharp, G. C.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S497 - S498