Evaluation of the Risk of Laboratory Microbial Contamination during Routine Testing in Automated Clinical Chemistry and Microbiology Laboratories

被引:8
|
作者
Farnsworth, Christopher W. [1 ]
Wallace, Meghan A. [1 ]
Liu, Albert [1 ]
Gronowski, Ann M. [1 ]
Burnham, Carey-Ann D. [1 ]
Yarbrough, Melanie L. [1 ]
机构
[1] Washington Univ, Dept Pathol & Immunol, Sch Med, 425 So Euclid Ave,Campus Box 8118, St Louis, MO 63110 USA
关键词
UNITED-STATES; INFECTIONS;
D O I
10.1093/clinchem/hvaa128
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Every clinical specimen is potentially infectious, but data regarding risk for contamination of the laboratory environment during routine testing are scarce. We assessed contamination during routine sample analysis in automated clinical chemistry and microbiology laboratories. METHODS: A fluorescent marker was applied to specimen container exteriors to assess the impact of gross contamination. Nonpathogenic MS2 virus was added to remnant blood, urine, and ESwab matrices as a biomarker of cross-contamination. Samples were processed and analyzed using Roche Cobas 8100 and ISE, c502, e602, and c702 modules (blood) and BD Kiestra total laboratory automation (blood, urine, ESwabs) over 3 experiments. Fluorescence transfer to laboratory surfaces and personnel was visualized using ultraviolet light. Surfaces were swabbed and assessed for MS2 cross-contamination by RT-PCR. Adherence to standard precautions by laboratory staff was assessed by observation. RESULTS: Fluorescence was observed on 49 of 165 (30%) laboratory surfaces and personnel and 21 of 93 (23%) total laboratory automation instruments. Fluorescence transferred most frequently to gloves (31/40), computer accessories (9/18), and specimen loading racks (12/12). None of 123 areas swabbed were positive for MS2. Improper personal protective equipment use occurred at a rate of 0.36 and 0.15 events per staff per hour in the chemistry and microbiology laboratories, respectively. Hand-washing compliance was observed for 61 of 132 (46%) staff members evaluated. CONCLUSIONS: Analysis of grossly contaminated specimens on automated chemistry and microbiology equipment elicits a low likelihood of instrument contamination. However, handling contaminated specimen containers can result in contamination of environmental laboratory surfaces, representing a source of risk that is heightened by low adherence to appropriate personal protective equipment.
引用
收藏
页码:1190 / 1199
页数:10
相关论文
共 50 条
  • [31] Analysis of the clinical outcomes of microbial contamination caused by environmental contamination of the embryology laboratory during IVF-ET treatment cycles
    Tingting Zheng
    Qinhua Li
    Ningjing Chen
    Peiyao Du
    Hong Ye
    BMC Pregnancy and Childbirth, 23
  • [32] Performance evaluation of the BD phoenix automated microbiology system in meropenem susceptibility testing of clinical Pseudomonas aeruginosa isolates
    Bayramoglu, Gulcin
    Acuner, Ibrahim C.
    Sinirtas, Melda
    Gedikoglu, Suna
    Durupinar, Belma
    SAUDI MEDICAL JOURNAL, 2006, 27 (12) : 1921 - 1923
  • [33] Prospective evaluation of the VITEK MS for the routine identification of bacteria and yeast in the clinical microbiology laboratory: assessment of accuracy of identification and turnaround time
    Charnot-Katsikas, Angella
    Tesic, Vera
    Boonlayangoor, Sue
    Bethel, Cindy
    Frank, Karen M.
    JOURNAL OF MEDICAL MICROBIOLOGY, 2014, 63 : 235 - 241
  • [34] Evaluation of add-on testing in the clinical chemistry laboratory of a large academic medical center - Reply
    Melanson, SF
    Lewandrowski, KB
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2005, 129 (04) : 454 - 454
  • [35] Evaluation of the BD Phoenix M50 Automated Microbiology System for Antimicrobial Susceptibility Testing with Clinical Isolates in Korea
    Hong, Jun Sung
    Kim, Dokyun
    Kang, Da Young
    Park, Byeol Yi
    Yang, SunMi
    Yoon, Eun-Jung
    Lee, Hyukmin
    Jeong, Seok Hoon
    MICROBIAL DRUG RESISTANCE, 2019, 25 (08) : 1142 - 1148
  • [36] Evaluation of bacterial contamination rate of the anterior chamber during phacoemulsification surgery using an automated microbial detection system
    Kocak, Ibrahim
    Kocak, Funda
    Teker, Bahri
    Aydin, Ali
    Kaya, Faruk
    Baybora, Hakan
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (04) : 686 - 688
  • [37] Evaluation of bacterial contamination rate of the anterior chamber during phacoemulsification surgery using an automated microbial detection system
    Ibrahim Kocak
    Funda Kocak
    Bahri Teker
    Ali Aydin
    Faruk Kaya
    Hakan Baybora
    International Journal of Ophthalmology, 2014, (04) : 686 - 688
  • [38] Evaluation of add-on testing in the clinical chemistry laboratory of a large academic medical center - Operational considerations
    Melanson, SF
    Hsieh, B
    Flood, JG
    Lewandrowski, KB
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2004, 128 (08) : 885 - 889
  • [39] The Analytical Performance Evaluation of Routine Clinical Chemistry Parameters by Six Sigma Approach: An Effective Tool for Laboratory Quality Management
    Rasheed, Asma
    Sharif, Sadia
    Humayun, Lubna
    Javaid, Faiza
    Agha, Muhammad Afaaq
    Ilyas, Anam
    Naeem, Tahir
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2024, 30 (03): : 282 - 288
  • [40] LONG-TERM EVALUATION OF CENTRIFICHEM CENTRIFUGAL MICROANALYZER DURING ROUTINE USE IN CLINICAL BIOCHEMISTRY LABORATORY
    FLEETWOOD, JA
    LATNER, AL
    MARRINER, A
    SKILLEN, AW
    SMITH, PA
    ANNALS OF CLINICAL BIOCHEMISTRY, 1977, 14 (SEP) : 279 - 284