Determination of 238U/235U, 236U/238U and uranium concentration in urine using SF-ICP-MS and MC-ICP-MS:: An interlaboratory comparison

被引:28
|
作者
Parrish, RR [1 ]
Thirlwall, MF
Pickford, C
Horstwood, M
Gerdes, A
Anderson, J
Coggon, D
机构
[1] Univ Leicester, Dept Geol, Keyworth NG12 5GG, Notts, England
[2] British Geol Survey, NERC, Isotope Geosci Lab, Keyworth NG12 5GG, Notts, England
[3] Univ London Royal Holloway & Bedford New Coll, Dept Geol, Egham TW20 0EX, Surrey, England
[4] Sci Ltd, Didcot OX11 0TB, Oxon, England
[5] Univ Southampton, Southampton Gen Hosp, MRC, Epidemiol Resource Ctr, Southampton SO16 6YD, Hants, England
来源
HEALTH PHYSICS | 2006年 / 90卷 / 02期
基金
英国医学研究理事会;
关键词
accident analysis; uranium; weapons; radiation; ionizing;
D O I
10.1097/01.HP.0000174809.43871.54
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Accidental exposure to depleted or enriched uranium may occur in a variety of circumstances. There is a need to quantify such exposure, with the possibility that the testing may post-date exposure by months or years. Therefore, it is important to develop a very sensitive test to measure precisely the isotopic composition of uranium in urine at low levels of concentration. The results of an interlaboratory comparison using sector field (SIF)-inductively coupled plasma-mass spectrometry (ICP-MS) and multiple collector (MC-ICP-MS for the measurement of uranium concentration and U-235/U-238 and U-236/U-231 isotopic ratios of human urine samples are presented. Three urine samples were verified to contain uranium at 1-5 ng L-1 and shown to have natural uranium isotopic composition. Portions of these urine batches were doped with depleted uranium (DU) containing small quantities of U-236, and the solutions were split into 100 mL and 400 mL aliquots that were subsequently measured blind by three laboratories. All methods investigated were able to measure accura tely U-238/U-235 With precisions of similar to 0.5% to similar to 4%, but only selected MC-ICP-MS methods were capable of consistently analyzi ng U-236/U-238 to reasonable precision at the similar to 20 fg L-1 level of U-236 abundance. Isotope dilution using a U-233 tracer demonstrates the ability to measure concentrations to better than +/- 4% with the MC-ICP-MS method, though sample heterogeneity in urine samples was shown to be problematic in some cases. MC-ICP-MS outperformed SF-ICP-MS methods, as was expected. The MC-ICP-MS methodology described is capable of measuring to similar to 1 % precision the U-238/U-235 of any sample of human urine over the entire range of uranium abundance down to < 1 Ing L-1, and detecting very small amounts of DU contained therein.
引用
收藏
页码:127 / 138
页数:12
相关论文
共 50 条
  • [21] A new method for determining 236U/238U isotope ratios in environmental samples by means OF ICP-MS/MS
    Diez-Fernandez, Silvia
    Jaegler, Hugo
    Bresson, Carole
    Chartier, Frederic
    Evrard, Olivier
    Hubert, Amelie
    Nonell, Anthony
    Pointurier, Fabien
    Isnard, Helene
    TALANTA, 2020, 206 (206)
  • [22] Improved abundance sensitivity in MC-ICP-MS for determination of 236U/238U isotope ratios in the 10-7 to 10-8 range
    Boulyga, Sergei F.
    Kloetzli, Urs
    Prohaska, Thomas
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (12) : 1427 - 1430
  • [23] A new milestone for ultra-low 236U/238U isotope ratio measurements by ICP-MS/MS
    Jaegler, Hugo
    Gourgiotis, Alkiviadis
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (10) : 1914 - 1919
  • [24] Search for spontaneous fission of 234U, 235U, 236U, and 238U by gamma spectrometry
    Danevich, F. A.
    Drapey, S. S.
    Kasperovych, D. V.
    Kirischuk, V. I.
    Kobychev, V. V.
    Kropivyansky, B. M.
    Tretyak, V. I.
    EUROPEAN PHYSICAL JOURNAL A, 2025, 61 (03):
  • [25] Natural fractionation of 238U/235U
    Weyer, S.
    Anbar, A. D.
    Gerdes, A.
    Gordon, G. W.
    Algeo, T. J.
    Boyle, E. A.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (02) : 345 - 359
  • [26] Behavior of uranium along Jucar River (eastern Spain): Determination of 234U/238U and 235U/238U ratios
    Instituto de Fisica Corpuscular, Avda. Dr. Moliner 50, Burjassot 46100, Valencia, Spain
    J. RADIOANAL. NUCL. CHEM., 1 (113-120):
  • [27] Background reduction in 236U/238U measurements
    Buompane, Raffaele
    De Cesare, Mario
    De Cesare, Nicola
    Di Leva, Antonino
    D'Onofrio, Antonio
    Fifield, L. Keith
    Froehlich, Michaela
    Gialanella, Lucio
    Marzaioli, Fabio
    Sabbarese, Carlo
    Terrasi, Filippo
    Tims, Stephen
    Wallner, Anton
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 361 : 454 - 457
  • [28] Historical changes of 236U/238U and 235U/238U isotopic ratios in Tokyo Bay from the 1960s to the 2000s
    Yoshida, Ami
    Shikimori, Junko
    Ohno, Takeshi
    Ijichi, Yuta
    Fukami, Yusuke
    Sakata, Masahiro
    Hirata, Takafumi
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2022, 255
  • [29] Closing in on the marine 238U/235U budget
    Andersen, M. B.
    Vance, D.
    Morford, J. L.
    Bura-Nakic, E.
    Breitenbach, S. F. M.
    Och, L.
    CHEMICAL GEOLOGY, 2016, 420 : 11 - 22
  • [30] Reliability of using 238U/235U and 234U/238U ratios from alpha spectrometry as qualitative indicators of enriched uranium contamination
    Minteer, Mark
    Winkler, Paul
    Wyatt, Bill
    Moreland, Scott
    Johnson, Jamie
    Winters, Tim
    HEALTH PHYSICS, 2007, 92 (05): : 488 - 495