Non-Contact Breathing Detection Using Passive Radar

被引:4
|
作者
Li, Wenda [1 ]
Tan, Bo [1 ]
Piechocki, Robert J. [1 ]
机构
[1] Univ Bristol, Dept Elect & Elect Engn, Bristol, Avon, England
基金
英国工程与自然科学研究理事会;
关键词
ALGORITHM;
D O I
10.1109/ICC.2016.7511389
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Non-contact breathing monitoring systems are very attractive for a range of e-Healthcare applications. This paper proposes a passive radar based system for measuring human breathing rate. A novel signal processing method is introduced to extract breathing rate based on micro Doppler derived from cross ambiguity function (CAF). The passive radar system is built within a software defined radio (SDR) platform. The proposed system uses opportunistically energy harvesting transmitter as an illumination signal. Passive detection is compared and verified using the ground truth from clinical chest belt respiration detector. Two experiments have been conducted to show the feasibility of passive detection system in the line of sight and also through-wall conditions. We conclude that a low frequency narrow band signal with non-contact passive detection can offer a realistic alternative to UWB based radars for future e-Healthcare passive sensing applications.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [32] Home Diagnosis Of Sleep-Disordered Breathing Using A Non-Contact Method
    Norman, M. B.
    Melehan, K.
    Sullivan, C. E.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [33] Non-Contact Breathing Rate Estimation Using Machine Learning with an Optimized Architecture
    Brieva, Jorge
    Ponce, Hiram
    Moya-Albor, Ernesto
    MATHEMATICS, 2023, 11 (03)
  • [34] Non-contact breathing rate monitoring in newborns: A review
    Maurya, Lalit
    Kaur, Pavleen
    Chawla, Deepak
    Mahapatra, Prasant
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 132
  • [35] Non-contact Vital Sign Detection Using Gain Detection Technique
    Peng, Kang-Chun
    Sung, Meng-Che
    Wang, Fu-Kang
    Horng, Tzyy-Sheng
    2021 IEEE INTERNATIONAL SYMPOSIUM ON RADIO-FREQUENCY INTEGRATION TECHNOLOGY (RFIT), 2021,
  • [36] Portable Micro-Doppler Radar with Quadrature Radar Architecture for Non-Contact Human Breath Detection
    Apriono, Catur
    Muin, Fathul
    Juwono, Filbert H.
    SENSORS, 2021, 21 (17)
  • [37] A Novel Non-Contact Respiration and Heartbeat Detection Method Using Frequency-Modulated Continuous Wave Radar
    Wang, Yong
    Liu, Heng
    Xiang, Wei
    Shui, Yuzhu
    Guo, Lei
    Zhou, Mu
    Pang, Yu
    IEEE SENSORS JOURNAL, 2024, 24 (07) : 10434 - 10446
  • [38] Non-Contact Vital Signs Detection Using mm-Wave Radar During Random Body Movements
    Liu, Luyao
    Zhang, Sen
    Xiao, Wendong
    PROCEEDINGS OF THE 2021 IEEE 16TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2021), 2021, : 1244 - 1249
  • [39] A 14 GHz Non-Contact Radar System for Long Range Heart Rate Detection
    Lee, Jee-Hoon
    Park, Seong-Ook
    2013 PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (ISAP), VOLS 1 AND 2, 2013,
  • [40] Non-Contact Vital Signs Monitoring of Dog and Cat Using a UWB Radar
    Wang, Pengfei
    Ma, Yangyang
    Liang, Fulai
    Zhang, Yang
    Yu, Xiao
    Li, Zhao
    An, Qiang
    Lv, Hao
    Wang, Jianqi
    ANIMALS, 2020, 10 (02):