Non-Contact Vital Signs Monitoring of Dog and Cat Using a UWB Radar

被引:30
|
作者
Wang, Pengfei [1 ]
Ma, Yangyang [1 ]
Liang, Fulai [1 ]
Zhang, Yang [1 ]
Yu, Xiao [1 ]
Li, Zhao [1 ]
An, Qiang [1 ]
Lv, Hao [1 ]
Wang, Jianqi [1 ]
机构
[1] Fourth Mil Med Univ, Sch Biomed Engn, Dept Med Elect, Xian 710032, Peoples R China
来源
ANIMALS | 2020年 / 10卷 / 02期
基金
中国国家自然科学基金;
关键词
cat; dog; vital signs monitoring; radar; ultra-wideband (UWB); variational mode decomposition (VMD); VARIATIONAL MODE DECOMPOSITION; HEART-RATE-VARIABILITY; ELECTROCARDIOGRAM; MICROWAVE; SENSORS; FAULT;
D O I
10.3390/ani10020205
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Simple Summary In this paper, we presented a new non-contact method to measure the vital signs of at-rest pets, where the ultra-wideband radar was applied for previously unachievable sensing ability and testing convenience. The proposed scheme did not interfere with the daily rhythm of the pet being tested; most subjects would not even notice the ongoing real-time monitoring due to the larger measurement coverage of the radar sensor. Through this work, we provided an innovative tool to promote not only the measurement of pet vital signs but also the improvement of animal welfare to prevent invasive, dangerous, and unacceptable contact measurement techniques, such as anesthesia, hair removal, and surgical implants. In addition, the proposed method could realize the daily vital signs measurement and sleep monitoring of dogs and cats, which is important for the diagnosis and timely treatment of pet diseases. As pets are considered members of the family, their health has received widespread attention. Since pets cannot talk and complain when they feel uncomfortable, monitoring vital signs becomes very helpful in disease detection, as well as observing their progression and response to treatment. In this study, we proposed an ultra-wideband radar-based, non-contact animal vital sign monitoring scheme that could monitor the breathing and heart rate of a pet in real-time. The primary advantage of the ultra-wideband radar was its ability to operate remotely without electrodes or wires and through any clothing or fur. Because of the existing noise and clutter in non-contact detection, background noise removal was applied. Furthermore, the respiration rate was directly obtained through spectrum analysis, while the heartbeat signal was extracted by the variational mode decomposition algorithm. By using electrocardiogram measurements, we verified the accuracy of the radar technology in detecting the anesthetized animals' respiratory rate and heart rate. Besides, three beagles and five cats in a non-sedated state were measured by radar and contact pressure sensors simultaneously; the experimental results showed that radar could effectively measure the respiration of cats and dogs, and the accuracy rate was over 95%. Due to its excellent performance, the proposed method has the potential to become a new choice in application scenarios, such as pet sleep monitoring and health assessment.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Non-Contact Detection of Vital Signs Using a UWB Radar Sensor
    Duan, Zhenzhen
    Liang, Jing
    IEEE ACCESS, 2019, 7 : 36888 - 36895
  • [2] Non-contact Detection of Vital Signs via a UWB Radar Sensor
    Duan, Zhenzhen
    Zhang, Yang
    Zhang, Jian
    Liang, Jing
    COMMUNICATIONS, SIGNAL PROCESSING, AND SYSTEMS, CSPS 2018, VOL II: SIGNAL PROCESSING, 2020, 516 : 708 - 716
  • [3] Harmonic Path (HAPA) Algorithm for Non-contact Vital Signs Monitoring with IR-UWB Radar
    Van Nguyen
    Javaid, Abdul Q.
    Weitnauer, Mary Ann
    2013 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2013, : 146 - 149
  • [4] Non-Contact Human Vital Signs Extraction Algorithms Using IR-UWB Radar: A Review
    Liang, Zhihuan
    Xiong, Mingyao
    Jin, Yanghao
    Chen, Jianlai
    Zhao, Dangjun
    Yang, Degui
    Liang, Buge
    Mo, Jinjun
    ELECTRONICS, 2023, 12 (06)
  • [5] A Measurement Study of FMCW Radar Configurations for Non-contact Vital Signs Monitoring
    Xie, Zongxing
    Hua, Yindong
    Ye, Fan
    2022 IEEE RADAR CONFERENCE (RADARCONF'22), 2022,
  • [6] Non-Contact Vital Sign Monitoring of Cat Using Continuous-Wave Doppler Radar
    Lai, Jun
    Lu, Jingyun
    Gu, Changzhan
    Mao, Jun-Fa
    2022 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY (ICMMT), 2022,
  • [7] Non-contact vital signs monitoring in broiler chickens
    Hossain, Md. Shafkat
    Pramanik, Sourav Kumar
    Rahman, Atikur
    Ali, Shahin
    Islam, Shekh Md Mahmudul
    JOURNAL OF ENGINEERING-JOE, 2023, 2023 (11):
  • [8] DistancePPG: Robust non-contact vital signs monitoring using a camera
    Kumar, Mayank
    Veeraraghavan, Ashok
    Sabharwal, Ashutosh
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (05): : 1565 - 1588
  • [9] Non-Contact Vital Signs Monitoring for Multiple Subjects Using a Millimeter Wave FMCW Automotive Radar
    Islam, Shekh M. M.
    Motoyama, Naoyuki
    Pacheco, Sergio
    Lubecke, Victor M.
    PROCEEDINGS OF THE 2020 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2020, : 783 - 786
  • [10] Non-Contact Determination of Vital Signs Monitoring of Animals in Hemorrhage States Using Bio-Radar
    Yu, Xiao
    Yin, Yue
    Lv, Hao
    Zhang, Yang
    Liang, Fulai
    Wang, Pengfei
    Wang, Jianqi
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2021, 100 : 23 - 34