Distal Femur Locking Plates Fit Poorly Before and After Total Knee Arthroplasty

被引:13
|
作者
Campbell, Sean T. [1 ]
Bosch, Liam C. [1 ]
Swinford, Steven [1 ]
Amanatullah, Derek F. [1 ]
Bishop, Julius A. [1 ]
Gardner, Michael J. [1 ]
机构
[1] Stanford Univ Hosp, Dept Orthopaed Surg, Stanford, CA 94305 USA
关键词
distal femur fracture; periprosthetic distal femur fracture; distal femur locking plate; translational deformity; total knee arthroplasty; FRACTURES; FIXATION;
D O I
10.1097/BOT.0000000000001431
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To evaluate the fit of distal femur locking plates. Secondarily, we sought to compare plate fit among patients with and without a total knee arthroplasty (TKA). Design: Retrospective. Setting: University hospital. Intervention: Standard length precontoured distal femur locking plates from 4 manufacturers were digitally templated onto each patient's pre-TKA and post-TKA radiographs. Main Outcome Measurements: The maximum distance from the plate to the lateral femoral cortex (plate-bone distance) was measured in the metaphyseal region. Mean plate-bone distances were compared between manufacturers and between pre-TKA and postTKA radiographs. Results: All implants tested were undercontoured in all patients. Plate-bone distances ranged from 6.6 0.4 mm to 8.0 0.4 mm (mean SE) pre-TKA and 8.2 0.3 mm to 8.6 0.3 mm after TKA, indicating worse fit after arthroplasty (P < 0.001). There were also intermanufacturer differences, with Synthes and Smith & Nephew implants demonstrating the lowest plate-bone distances in the pre-TKA and post-TKA groups, respectively. Proportionally, plate-bone increase was greater in the female cohort (16%) compared with the male cohort (8%). Conclusions: There was plate-bone mismatch for the distal femur locking plates tested in this study, due to undercontouring of the implants. After patients underwent TKA, poor implant fit was exacerbated. Surgeons must be aware of the potential for deformity if the proximal segment is brought into contact with the implant. These finding may help optimize implant design for the treatment of periprosthetic distal femur fractures.
引用
收藏
页码:239 / 243
页数:5
相关论文
共 50 条
  • [31] Passive knee kinematics before and after total knee arthroplasty
    Mihalko, William M.
    Ali, Mounawar
    Phillips, Matthew J.
    Bayers-Thering, Mary
    Krackow, Kenneth A.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 57 - 60
  • [32] Cutting Error of the Distal Femur in Total Knee Arthroplasty by Use of a Navigation System
    Nakahara, Hiroyuki
    Matsuda, Shuichi
    Moro-oka, Taka-aki
    Okazaki, Ken
    Tashiro, Yasutaka
    Iwamoto, Yukihide
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 1119 - 1122
  • [33] Total knee arthroplasty for salvage of failed internal fixation or nonunion of the distal femur
    Haidukewych, GJ
    Springer, BD
    Jacofsky, DJ
    Berry, DJ
    JOURNAL OF ARTHROPLASTY, 2005, 20 (03): : 344 - 349
  • [34] Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty
    Kanekasu, K
    Kondo, M
    Kadoya, Y
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (434) : 193 - 197
  • [35] TOTAL KNEE REPLACEMENT AFTER TUMOR RESECTION OF THE DISTAL FEMUR
    JOHANSSON, E
    NILSONNE, U
    ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (06): : 700 - 700
  • [36] Distal rotational alignment of the Chinese femur and its relevance in total knee arthroplasty
    Yip, DKH
    Zhu, YH
    Chiu, KY
    Ng, TP
    JOURNAL OF ARTHROPLASTY, 2004, 19 (05): : 613 - 619
  • [37] Primary total knee arthroplasty for complex distal femur fractures in elderly patients
    Strauss, E
    Rosen, A
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S22 - S22
  • [38] Primary total knee arthroplasty for complex distal femur fractures in elderly patients
    Rosen, AL
    Strauss, E
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (425) : 101 - 105
  • [39] Retrograde Intramedullary Nail for Distal Femur Fracture, Through a Total Knee Arthroplasty
    Davis, Max
    Wilson, Jenna
    Weick, Jack
    Hake, Mark
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2021, 35 : S30 - S31
  • [40] Robotic-Assisted Total Knee Arthroplasty for Distal Femur Fracture with Lateral Knee Osteoarthritis
    Kaneko, Takao
    Igarashi, Tadashi
    Yoshizawa, Shu
    Takada, Kazutaka
    Ikegami, Hiroyasu
    Musha, Yoshiro
    CASE REPORTS IN ORTHOPEDICS, 2021, 2021