Distal Femur Locking Plates Fit Poorly Before and After Total Knee Arthroplasty

被引:13
|
作者
Campbell, Sean T. [1 ]
Bosch, Liam C. [1 ]
Swinford, Steven [1 ]
Amanatullah, Derek F. [1 ]
Bishop, Julius A. [1 ]
Gardner, Michael J. [1 ]
机构
[1] Stanford Univ Hosp, Dept Orthopaed Surg, Stanford, CA 94305 USA
关键词
distal femur fracture; periprosthetic distal femur fracture; distal femur locking plate; translational deformity; total knee arthroplasty; FRACTURES; FIXATION;
D O I
10.1097/BOT.0000000000001431
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To evaluate the fit of distal femur locking plates. Secondarily, we sought to compare plate fit among patients with and without a total knee arthroplasty (TKA). Design: Retrospective. Setting: University hospital. Intervention: Standard length precontoured distal femur locking plates from 4 manufacturers were digitally templated onto each patient's pre-TKA and post-TKA radiographs. Main Outcome Measurements: The maximum distance from the plate to the lateral femoral cortex (plate-bone distance) was measured in the metaphyseal region. Mean plate-bone distances were compared between manufacturers and between pre-TKA and postTKA radiographs. Results: All implants tested were undercontoured in all patients. Plate-bone distances ranged from 6.6 0.4 mm to 8.0 0.4 mm (mean SE) pre-TKA and 8.2 0.3 mm to 8.6 0.3 mm after TKA, indicating worse fit after arthroplasty (P < 0.001). There were also intermanufacturer differences, with Synthes and Smith & Nephew implants demonstrating the lowest plate-bone distances in the pre-TKA and post-TKA groups, respectively. Proportionally, plate-bone increase was greater in the female cohort (16%) compared with the male cohort (8%). Conclusions: There was plate-bone mismatch for the distal femur locking plates tested in this study, due to undercontouring of the implants. After patients underwent TKA, poor implant fit was exacerbated. Surgeons must be aware of the potential for deformity if the proximal segment is brought into contact with the implant. These finding may help optimize implant design for the treatment of periprosthetic distal femur fractures.
引用
收藏
页码:239 / 243
页数:5
相关论文
共 50 条
  • [21] Periprosthetic fractures of the femur after total knee arthroplasty
    McGraw P.
    Kumar A.
    Journal of Orthopaedics and Traumatology, 2010, 11 (3) : 135 - 141
  • [22] Distal femur replacement is useful in complex total knee arthroplasty revisions
    Harrison, Richard J., Jr.
    Thacker, Mihir M.
    Pitcher, J. David
    Temple, H. Thomas
    Scully, Sean P.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (446) : 113 - 120
  • [23] SUPRACONDYLAR FRACTURE OF THE FEMUR AFTER TOTAL KNEE ARTHROPLASTY
    AARON, RK
    SCOTT, R
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1987, (219) : 136 - 139
  • [24] Abaloparatide Increases Distal Femur BMD Post Total Knee Arthroplasty
    Binkley, Neil
    Krueger, Diane
    Borchardt, Gretta
    Nickel, Brian
    Anderson, Paul
    JOURNAL OF BONE AND MINERAL RESEARCH, 2023, 38 : 356 - 356
  • [25] Conversion of Fused Knee Following Distal Femur Tumor Surgery to Total Knee Arthroplasty
    Jamshidi, Khodamorad
    Hadi, Hoseinali
    Shirazi, Mehdi Ramezan
    Moslem, Alireza
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2013, 15 (09) : 870 - 872
  • [26] Clinical outcome and quality of life of patients with periprosthetic distal femur fractures and retained total knee arthroplasty treated with polyaxial locking plates: a single-center experience
    Sebastian Lotzien
    Clemens Hoberg
    Martin F. Hoffmann
    Thomas A. Schildhauer
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 189 - 196
  • [27] Clinical outcome and quality of life of patients with periprosthetic distal femur fractures and retained total knee arthroplasty treated with polyaxial locking plates: a single-center experience
    Lotzien, Sebastian
    Hoberg, Clemens
    Hoffmann, Martin F.
    Schildhauer, Thomas A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (01): : 189 - 196
  • [28] The effect of alendronate on bone mineral density of the distal femur and proximal tibia after total knee arthroplasty
    Wang, CJ
    Weng, LS
    Hsu, CC
    Chen, HS
    BONE, 2003, 32 (05) : S204 - S204
  • [29] The Outcome and Complications of the Locked Plating Management for the Periprosthetic Distal Femur Fractures after a Total Knee Arthroplasty
    Gavaskar, Ashok S.
    Tummala, Naveen Chowdary
    Subramanian, Muthukumar
    CLINICS IN ORTHOPEDIC SURGERY, 2013, 5 (02) : 124 - 128
  • [30] Rotating-hinge total knee arthroplasty in a patient with genu recurvatum after osteomyelitis of the distal femur
    Nishitani, Kohei
    Nakagawa, Yasuaki
    Suzuki, Takashi
    Koike, Kazuhiro
    Nakamura, Takashi
    JOURNAL OF ARTHROPLASTY, 2007, 22 (04): : 630 - 633