Distal Femur Locking Plates Fit Poorly Before and After Total Knee Arthroplasty

被引:13
|
作者
Campbell, Sean T. [1 ]
Bosch, Liam C. [1 ]
Swinford, Steven [1 ]
Amanatullah, Derek F. [1 ]
Bishop, Julius A. [1 ]
Gardner, Michael J. [1 ]
机构
[1] Stanford Univ Hosp, Dept Orthopaed Surg, Stanford, CA 94305 USA
关键词
distal femur fracture; periprosthetic distal femur fracture; distal femur locking plate; translational deformity; total knee arthroplasty; FRACTURES; FIXATION;
D O I
10.1097/BOT.0000000000001431
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To evaluate the fit of distal femur locking plates. Secondarily, we sought to compare plate fit among patients with and without a total knee arthroplasty (TKA). Design: Retrospective. Setting: University hospital. Intervention: Standard length precontoured distal femur locking plates from 4 manufacturers were digitally templated onto each patient's pre-TKA and post-TKA radiographs. Main Outcome Measurements: The maximum distance from the plate to the lateral femoral cortex (plate-bone distance) was measured in the metaphyseal region. Mean plate-bone distances were compared between manufacturers and between pre-TKA and postTKA radiographs. Results: All implants tested were undercontoured in all patients. Plate-bone distances ranged from 6.6 0.4 mm to 8.0 0.4 mm (mean SE) pre-TKA and 8.2 0.3 mm to 8.6 0.3 mm after TKA, indicating worse fit after arthroplasty (P < 0.001). There were also intermanufacturer differences, with Synthes and Smith & Nephew implants demonstrating the lowest plate-bone distances in the pre-TKA and post-TKA groups, respectively. Proportionally, plate-bone increase was greater in the female cohort (16%) compared with the male cohort (8%). Conclusions: There was plate-bone mismatch for the distal femur locking plates tested in this study, due to undercontouring of the implants. After patients underwent TKA, poor implant fit was exacerbated. Surgeons must be aware of the potential for deformity if the proximal segment is brought into contact with the implant. These finding may help optimize implant design for the treatment of periprosthetic distal femur fractures.
引用
收藏
页码:239 / 243
页数:5
相关论文
共 50 条
  • [1] Heterotopic ossification around distal femur after total knee arthroplasty
    Hasegawa, M
    Ohashi, T
    Uchida, A
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (05) : 274 - 278
  • [2] BONE LOSS IN THE DISTAL ANTERIOR FEMUR AFTER TOTAL KNEE ARTHROPLASTY
    MINTZER, CM
    ROBERTSON, DD
    RACKEMANN, S
    EWALD, FC
    SCOTT, RD
    SPECTOR, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (260) : 135 - 143
  • [3] Heterotopic ossification around distal femur after total knee arthroplasty
    Masahiro Hasegawa
    Toshiro Ohashi
    Atsumasa Uchida
    Archives of Orthopaedic and Trauma Surgery, 2002, 122 : 274 - 278
  • [4] Total knee arthroplasty after varus osteotomy of the distal part of the femur
    Nelson, CL
    Saleh, KJ
    Kassim, RA
    Windsor, R
    Haas, S
    Laskin, R
    Sculco, T
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (06): : 1062 - 1065
  • [5] Osteosynthesis by locking compression plate for periprosthetic fractures of the distal femur after knee arthroplasty
    Ehlinger, Matthieu
    Adam, Philippe
    Bonnomet, Francois
    Arlettaz, Yvan
    SWISS MEDICAL WEEKLY, 2011, 141 : 20S - 20S
  • [6] Treatment of distal femur fractures with locking plates : Comparison of periprosthetic fractures above total knee arthroplasty and non-periprosthetic fractures
    Song, Sang Jun
    Kim, Kang Il
    Song, Wook Jae
    Kim, Dong Kyoon
    Bae, Dae Kyung
    ACTA ORTHOPAEDICA BELGICA, 2014, 80 (03): : 380 - 390
  • [7] Treatment of fractures of the distal femur on total knee arthroplasty
    Hernigou, P
    Poignard, A
    Manicom, O
    Chabane-Sari, MA
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2006, 92 (02): : 148 - 157
  • [8] DISTAL FEMUR FRACTURE ABOVE A TOTAL KNEE ARTHROPLASTY
    PATCH, DA
    IORIO, R
    HEALY, WL
    ORTHOPEDICS, 1994, 17 (04) : 371 - 374
  • [9] Periprosthetic bone mineral density of the distal femur after total knee arthroplasty
    Liu, TK
    Yang, RS
    Chieng, PU
    Shee, BW
    INTERNATIONAL ORTHOPAEDICS, 1995, 19 (06) : 346 - 351
  • [10] Periprosthetic Distal Femur Fracture after Total Knee Arthroplasty: A Systematic Review
    Ebraheim, Nabil A.
    Kelley, Leanne H.
    Liu, Xiaochen
    Thomas, Ian S.
    Steiner, Robert B.
    Liu, Jiayong
    ORTHOPAEDIC SURGERY, 2015, 7 (04) : 297 - 305