Temperature-controlled slow pathway ablation for treatment of atrioventricular nodal reentrant tachycardia using a combined anatomical and electrogram guided strategy

被引:0
|
作者
Willems, S [1 ]
Shenasa, H [1 ]
Kottkamp, H [1 ]
Chen, X [1 ]
Hindricks, G [1 ]
YliMayry, S [1 ]
Haverkamp, W [1 ]
Wichter, T [1 ]
Rotman, B [1 ]
Breithardt, G [1 ]
Borggrefe, M [1 ]
机构
[1] UNIV KLIN MUNSTER, INST ARTERIOSCLEROSIS RES, D-48129 MUNSTER, GERMANY
关键词
catheter ablation; atrioventricular nodal reentrant tachycardia; slow pathway; supraventricular tachycardia; temperature control;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Anatomical and electrogram-guided techniques have been used separately for slow pathway ablation in atrioventricular nodal reentrant tachycardia. The aims of the present study were to analyse electrogram characteristics of target sites and biophysical parameters using a combined anatomical and electrogram-guided technique for temperature-controlled radiofrequency catheter ablation of the slow pathway. Methods and results Using a temperature-controlled (pre-selected 60 degrees C) catheter system, 53 patients with atrioventricular nodal reentrant tachycardia underwent slow pathway radiofrequency ablation. Mapping was started posteroseptally near the coronary sinus ostium and continued towards the midseptal area if needed. The longest and latest atrial electrograms with an atrioventricular ratio of less than or equal to 0 . 5 were targeted. After a median of two pulses (mean 2 . 36+/-1 . 33), atrioventricular nodal reentrant tachycardia was rendered non-inducible in all patients without complications. Successful sites had longer atrial electrograms (78 . 8+/-9 . 8 vs 67 . 6+/-13 . 3 ms, P<0 . 003) and larger ventricular electrogram amplitudes (92 . 4+/-51 . 2 vs 63 . 1+/-28 . 8 mV, P<0 . 05) than the failed sites, but had a similar atrioventricular ratio, P-A interval and atrial electrogram amplitude. Overall, an atrial electrogram duration of greater than or equal to 70 ms was associated with effective radiofrequency delivery, with 86% sensitivity and 62% specificity. The achieved temperature maximum was 62 . 3+/-9 . 8 degrees C at successful and 58 . 8+/-9 . 0 . C at unsuccessful sites (ns). There was no significant difference between successful and unsuccessful applications with respect to power output, impedance and total delivery energy. During a pre-discharge study, three patients with inducible atrioventricular nodal reentrant tachycardia underwent a repeat ablation. During 12 . 3+/-2 . 5 (6-15) months of follow-up, three others had a clinical recurrence of atrioventricular nodal reentrant tachycardia. Conclusions The combined approach for slow pathway ablation is highly effective, requiring a low number of radiofrequency pulses. Long atrial activation time seems to be the most powerful predictor of success. Similar catheter tip temperature levels during successful and unsuccessful radiofrequency applications indicate that suboptimal selection of target sites rather than ineffective heating due to poor catheter tissue coupling is responsible for unsuccessful energy delivery.
引用
收藏
页码:1092 / 1102
页数:11
相关论文
共 50 条
  • [41] Selective radiofrequency catheter ablation of the slow pathway for common and uncommon atrioventricular nodal reentrant tachycardia
    Iesaka, Y
    Takahashi, A
    Goya, M
    Yamane, T
    Kojima, S
    Fujiwara, H
    Nitta, J
    Nogami, A
    Aonuma, K
    Hiroe, M
    Marumo, F
    Hiraoka, M
    JAPANESE HEART JOURNAL, 1996, 37 (05): : 759 - 770
  • [42] SAFETY AND COST OF OUTPATIENT RADIOFREQUENCY ABLATION OF THE SLOW PATHWAY IN PATIENTS WITH ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA
    MAN, KC
    KALBFLEISCH, SJ
    HUMMEL, JD
    WILLIAMSON, BD
    VORPERIAN, VR
    STRICKBERGER, SA
    LANGBERG, JJ
    MORADY, F
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (17): : 1323 - 1324
  • [43] TEMPERATURE-CONTROLLED RADIOFREQUENCY ABLATION OF ACCESSORY PATHWAYS AND ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA - THE 5-FRENCH CATHETER APPROACH
    KOTTKAMP, H
    HINDRICKS, G
    CHEN, X
    WICHTER, T
    WILLEMS, S
    HAVERKAMP, W
    MARTINEZRUBIO, A
    YLIMAYRY, S
    BREITHARDT, G
    BORGGREFE, M
    CIRCULATION, 1995, 92 (08) : 3822 - 3822
  • [44] ELECTROPHYSIOLOGIC SPECTRUM OF ATRIOVENTRICULAR NODAL BEHAVIOR IN PATIENTS WITH ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA UNDERGOING SELECTIVE FAST OR SLOW PATHWAY ABLATION
    JAZAYERI, MR
    SRA, JS
    DESHPANDE, SS
    BLANCK, Z
    DHALA, AA
    KRUM, DP
    AVITALL, B
    AKHTAR, M
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1993, 4 (02) : 99 - 111
  • [45] Site of successful slow pathway ablation relates to clinical tachycardia rate in patients with atrioventricular nodal reentrant tachycardia
    Dagres, N
    Manolis, AS
    Maounis, T
    Poulos, G
    Cokkinos, DV
    Borggrefe, M
    HEART, 2006, 92 (01) : 115 - 116
  • [46] Slow pathway ablation using electro-anatomical mapping in a patient with corrected transposition of the great arteries, dextrocardia, and atrioventricular nodal reentrant tachycardia
    Cui, Kaijun
    Chen, Xiaoping
    Li, Jiong
    EUROPACE, 2013, 15 (01): : 155 - 155
  • [47] Successful ablation site of the slow pathway relates to clinical tachycardia rate in patients with atrioventricular nodal reentrant tachycardia
    Dagres, N
    Maounis, T
    Poulos, G
    Manolis, AS
    Cokkinos, DV
    Borggrefe, M
    EUROPEAN HEART JOURNAL, 2004, 25 : 277 - +
  • [48] Optimal slow pathway ablation site for slow-fast atrioventricular nodal reentrant tachycardia with 2:1 atrioventricular conduction
    Iwasawa, Jin
    Miyazaki, Shinsuke
    Takagi, Takamitsu
    Taniguchi, Hiroshi
    Nakamura, Hiroaki
    Hachiya, Hitoshi
    Iesaka, Yoshito
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2017, 48 (02) : 209 - 214
  • [49] Optimal slow pathway ablation site for slow-fast atrioventricular nodal reentrant tachycardia with 2:1 atrioventricular conduction
    Jin Iwasawa
    Shinsuke Miyazaki
    Takamitsu Takagi
    Hiroshi Taniguchi
    Hiroaki Nakamura
    Hitoshi Hachiya
    Yoshito Iesaka
    Journal of Interventional Cardiac Electrophysiology, 2017, 48 : 209 - 214
  • [50] A Randomized Comparison of Fixed Power and Temperature Monitoring During Slow Pathway Ablation in Patients With Atrioventricular Nodal Reentrant Tachycardia
    S. Adam Strickberger
    Emile G. Daoud
    Raul Weiss
    Karin Brinkman
    Frank Bogun
    Bradley P. Knight
    Marwan Bahu
    Rajiva Goyal
    K. Ching Man
    Fred Morady
    Journal of Interventional Cardiac Electrophysiology, 1997, 1 (4) : 299 - 303