Temperature-controlled slow pathway ablation for treatment of atrioventricular nodal reentrant tachycardia using a combined anatomical and electrogram guided strategy

被引:0
|
作者
Willems, S [1 ]
Shenasa, H [1 ]
Kottkamp, H [1 ]
Chen, X [1 ]
Hindricks, G [1 ]
YliMayry, S [1 ]
Haverkamp, W [1 ]
Wichter, T [1 ]
Rotman, B [1 ]
Breithardt, G [1 ]
Borggrefe, M [1 ]
机构
[1] UNIV KLIN MUNSTER, INST ARTERIOSCLEROSIS RES, D-48129 MUNSTER, GERMANY
关键词
catheter ablation; atrioventricular nodal reentrant tachycardia; slow pathway; supraventricular tachycardia; temperature control;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Anatomical and electrogram-guided techniques have been used separately for slow pathway ablation in atrioventricular nodal reentrant tachycardia. The aims of the present study were to analyse electrogram characteristics of target sites and biophysical parameters using a combined anatomical and electrogram-guided technique for temperature-controlled radiofrequency catheter ablation of the slow pathway. Methods and results Using a temperature-controlled (pre-selected 60 degrees C) catheter system, 53 patients with atrioventricular nodal reentrant tachycardia underwent slow pathway radiofrequency ablation. Mapping was started posteroseptally near the coronary sinus ostium and continued towards the midseptal area if needed. The longest and latest atrial electrograms with an atrioventricular ratio of less than or equal to 0 . 5 were targeted. After a median of two pulses (mean 2 . 36+/-1 . 33), atrioventricular nodal reentrant tachycardia was rendered non-inducible in all patients without complications. Successful sites had longer atrial electrograms (78 . 8+/-9 . 8 vs 67 . 6+/-13 . 3 ms, P<0 . 003) and larger ventricular electrogram amplitudes (92 . 4+/-51 . 2 vs 63 . 1+/-28 . 8 mV, P<0 . 05) than the failed sites, but had a similar atrioventricular ratio, P-A interval and atrial electrogram amplitude. Overall, an atrial electrogram duration of greater than or equal to 70 ms was associated with effective radiofrequency delivery, with 86% sensitivity and 62% specificity. The achieved temperature maximum was 62 . 3+/-9 . 8 degrees C at successful and 58 . 8+/-9 . 0 . C at unsuccessful sites (ns). There was no significant difference between successful and unsuccessful applications with respect to power output, impedance and total delivery energy. During a pre-discharge study, three patients with inducible atrioventricular nodal reentrant tachycardia underwent a repeat ablation. During 12 . 3+/-2 . 5 (6-15) months of follow-up, three others had a clinical recurrence of atrioventricular nodal reentrant tachycardia. Conclusions The combined approach for slow pathway ablation is highly effective, requiring a low number of radiofrequency pulses. Long atrial activation time seems to be the most powerful predictor of success. Similar catheter tip temperature levels during successful and unsuccessful radiofrequency applications indicate that suboptimal selection of target sites rather than ineffective heating due to poor catheter tissue coupling is responsible for unsuccessful energy delivery.
引用
收藏
页码:1092 / 1102
页数:11
相关论文
共 50 条
  • [31] HISTOPATHOLOGICAL STUDY FOLLOWING CATHETER GUIDED RADIOFREQUENCY CURRENT ABLATION OF THE SLOW PATHWAY IN A PATIENT WITH ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA
    GAMACHE, MC
    BHARATI, S
    LEV, M
    LINDSAY, BD
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (02): : 247 - 251
  • [32] RANDOMIZED COMPARISON OF ANATOMIC AND ELECTROGRAM MAPPING APPROACHES TO ABLATION OF THE SLOW PATHWAY OF ATRIOVENTRICULAR NODE REENTRANT TACHYCARDIA
    KALBFLEISCH, SJ
    STRICKBERGER, SA
    WILLIAMSON, B
    VORPERIAN, VR
    MAN, C
    HUMMEL, JD
    LANGBERG, JJ
    MORADY, F
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (03) : 716 - 723
  • [33] Novel near-field detection algorithm-guided slow pathway ablation in atrioventricular nodal reentrant tachycardia
    Kawaji, Tetsuma
    Yamano, Saki
    Aizawa, Takanori
    Naka, Misaki
    Bao, Bingyuan
    Hojo, Shun
    Tezuka, Yuji
    Matsuda, Shintaro
    Kato, Masashi
    Yokomatsu, Takafumi
    Miki, Shinji
    HEART RHYTHM, 2024, 21 (08) : 1440 - 1442
  • [34] Successful slow pathway ablation in a patient with atrioventricular nodal reentrant tachycardia having a proximal common pathway
    Chinushi, M
    Aizawa, Y
    Ogawa, Y
    Fujita, S
    Kusano, Y
    Miyajima, S
    Shibata, A
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (06): : 1316 - 1318
  • [35] Anatomical features determining the difficulty of ablation in atrioventricular nodal reentrant tachycardia
    Garweg, C.
    Willems, R.
    De Buck, S.
    Louw, R.
    Ector, J.
    EUROPEAN HEART JOURNAL, 2015, 36 : 559 - 559
  • [36] Effect of slow pathway ablation/modification on the fast pathway properties in patients with atrioventricular nodal reentrant tachycardia
    Zimmermann, M
    EUROPEAN HEART JOURNAL, 2002, 23 : 661 - 661
  • [37] Abbreviated combined anatomical/electrophysiological approach for catheter ablation of atrioventricular nodal reentrant tachycardia in children
    Bertram, H
    Windhagen-Mahnert, B
    Bökenkamp, R
    Kriebel, T
    Peuster, M
    Hausdorf, G
    Paul, T
    CARDIOLOGY IN THE YOUNG, 2001, 11 (02) : 182 - 187
  • [38] INFLUENCE OF RADIOFREQUENCY POWER OUTPUT ON SELECTIVE SLOW PATHWAY ABLATION OF ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA
    FITZGERALD, DM
    ZORNOSA, JP
    MATISTA, JF
    HAISTY, WK
    SIMMONS, TW
    CROSSLEY, GH
    CIRCULATION, 1993, 88 (04) : 492 - 492
  • [39] COINCIDENT IDIOPATHIC LEFT-VENTRICULAR TACHYCARDIA AND ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA - CONTROL BY RADIOFREQUENCY CATHETER ABLATION OF THE SLOW ATRIOVENTRICULAR NODAL PATHWAY
    WAGSHAL, AB
    MITTLEMAN, RS
    SCHUGER, CD
    HUANG, SKS
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (03): : 386 - 396
  • [40] IMPACT OF THE LOCAL ATRIAL ELECTROGRAM IN AV NODAL REENTRANT TACHYCARDIA - ABLATION VERSUS MODIFICATION OF THE SLOW PATHWAY
    TEBBENJOHANNS, J
    PFEIFFER, D
    SCHUMACHER, B
    MANZ, M
    LUDERITZ, B
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1995, 6 (04) : 245 - 251