Temperature-controlled slow pathway ablation for treatment of atrioventricular nodal reentrant tachycardia using a combined anatomical and electrogram guided strategy

被引:0
|
作者
Willems, S [1 ]
Shenasa, H [1 ]
Kottkamp, H [1 ]
Chen, X [1 ]
Hindricks, G [1 ]
YliMayry, S [1 ]
Haverkamp, W [1 ]
Wichter, T [1 ]
Rotman, B [1 ]
Breithardt, G [1 ]
Borggrefe, M [1 ]
机构
[1] UNIV KLIN MUNSTER, INST ARTERIOSCLEROSIS RES, D-48129 MUNSTER, GERMANY
关键词
catheter ablation; atrioventricular nodal reentrant tachycardia; slow pathway; supraventricular tachycardia; temperature control;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Anatomical and electrogram-guided techniques have been used separately for slow pathway ablation in atrioventricular nodal reentrant tachycardia. The aims of the present study were to analyse electrogram characteristics of target sites and biophysical parameters using a combined anatomical and electrogram-guided technique for temperature-controlled radiofrequency catheter ablation of the slow pathway. Methods and results Using a temperature-controlled (pre-selected 60 degrees C) catheter system, 53 patients with atrioventricular nodal reentrant tachycardia underwent slow pathway radiofrequency ablation. Mapping was started posteroseptally near the coronary sinus ostium and continued towards the midseptal area if needed. The longest and latest atrial electrograms with an atrioventricular ratio of less than or equal to 0 . 5 were targeted. After a median of two pulses (mean 2 . 36+/-1 . 33), atrioventricular nodal reentrant tachycardia was rendered non-inducible in all patients without complications. Successful sites had longer atrial electrograms (78 . 8+/-9 . 8 vs 67 . 6+/-13 . 3 ms, P<0 . 003) and larger ventricular electrogram amplitudes (92 . 4+/-51 . 2 vs 63 . 1+/-28 . 8 mV, P<0 . 05) than the failed sites, but had a similar atrioventricular ratio, P-A interval and atrial electrogram amplitude. Overall, an atrial electrogram duration of greater than or equal to 70 ms was associated with effective radiofrequency delivery, with 86% sensitivity and 62% specificity. The achieved temperature maximum was 62 . 3+/-9 . 8 degrees C at successful and 58 . 8+/-9 . 0 . C at unsuccessful sites (ns). There was no significant difference between successful and unsuccessful applications with respect to power output, impedance and total delivery energy. During a pre-discharge study, three patients with inducible atrioventricular nodal reentrant tachycardia underwent a repeat ablation. During 12 . 3+/-2 . 5 (6-15) months of follow-up, three others had a clinical recurrence of atrioventricular nodal reentrant tachycardia. Conclusions The combined approach for slow pathway ablation is highly effective, requiring a low number of radiofrequency pulses. Long atrial activation time seems to be the most powerful predictor of success. Similar catheter tip temperature levels during successful and unsuccessful radiofrequency applications indicate that suboptimal selection of target sites rather than ineffective heating due to poor catheter tissue coupling is responsible for unsuccessful energy delivery.
引用
收藏
页码:1092 / 1102
页数:11
相关论文
共 50 条
  • [1] A simple technique for anatomical slow pathway ablation in atrioventricular nodal reentrant tachycardia
    Enjoji, Y
    Sugi, K
    Ikeda, T
    Sakata, T
    Noro, M
    Kondo, N
    Takami, M
    Tezuka, N
    Nakae, T
    Yamaguchi, T
    JAPANESE HEART JOURNAL, 1999, 40 (05): : 561 - 569
  • [2] TEMPERATURE-GUIDED RADIOFREQUENCY CATHETER ABLATION OF SLOW PATHWAY IN ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA
    CHOI, YS
    SOHN, KS
    SOHN, DW
    OH, BH
    LEE, MM
    PARK, YB
    SEO, JD
    LEE, YW
    AMERICAN HEART JOURNAL, 1995, 129 (02) : 392 - 394
  • [3] Optimal target temperature for slow pathway ablation in patients with atrioventricular nodal reentrant tachycardia
    Majid Haghjoo
    Arash Arya
    Alireza Heidari
    Amir Farjam Fazelifar
    MohammadAli Sadr-Ameli
    Journal of Interventional Cardiac Electrophysiology, 2006, 15 : 165 - 170
  • [4] Optimal target temperature for slow pathway ablation in patients with atrioventricular nodal reentrant tachycardia
    Haghjoo, Majid
    Arya, Arash
    Heidari, Alireza
    Fazelifar, Amir Farjam
    Sadr-Ameli, MohammadAli
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 15 (03) : 165 - 170
  • [5] Left septal slow pathway ablation for atrioventricular nodal reentrant tachycardia
    Zografos, T.
    John, R. M.
    Latchamsetty, R.
    Muthalaly, R. G.
    Katritsis, G. D.
    Stevenson, W. G.
    Efimov, I. R.
    Morady, F.
    Katritsis, D. G.
    EUROPEAN HEART JOURNAL, 2018, 39 : 1021 - 1021
  • [6] Left septal slow pathway ablation for atrioventricular nodal reentrant tachycardia
    Katritsis, Demosthenes G.
    EUROPACE, 2010, 12 (07): : 1042 - 1043
  • [7] Cryothermal ablation of the slow pathway for the elimination of atrioventricular nodal reentrant tachycardia
    Skanes, AC
    Dubuc, M
    Klein, GJ
    Thibault, B
    Krahn, AD
    Yee, R
    Roy, D
    Guerra, P
    Talajic, M
    CIRCULATION, 2000, 102 (23) : 2856 - 2860
  • [8] Left Septal Slow Pathway Ablation for Atrioventricular Nodal Reentrant Tachycardia
    Katritsis, Demosthenes G.
    John, Roy M.
    Latchamsetty, Rakesh
    Muthalaly, Rahul G.
    Zografos, Theodoros
    Katritsis, George D.
    Stevenson, William G.
    Efimov, Igor R.
    Morady, Fred
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2018, 11 (03):
  • [9] Intracardiac echocardiography guided radiofrequency catheter ablation of the slow pathway in atrioventricular nodal reentrant tachycardia
    Batra, R
    Nair, M
    Kumar, M
    Mohan, J
    Shah, P
    Kaul, U
    Arora, R
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2002, 6 (01) : 43 - 49
  • [10] Intracardiac Echocardiography Guided Radiofrequency Catheter Ablation of the Slow Pathway in Atrioventricular Nodal Reentrant Tachycardia
    Ravinder Batra
    Mohan Nair
    Manoj Kumar
    Jagdish Mohan
    Prasad Shah
    Upkar Kaul
    Ramesh Arora
    Journal of Interventional Cardiac Electrophysiology, 2002, 6 : 43 - 49