Research On The Detection Of Faulty Insulator Strings

被引:1
|
作者
Nie Yi-xiong [1 ]
Peng Xian-gang [1 ]
Xu Xiao-ning [2 ]
机构
[1] Guangdong Univ Tech, Fac Automat, Guangzhou 510006, Guangdong, Peoples R China
[2] Guangzhou Univ, Coll Civil Engn, Guangzhou 510006, Guangdong, Peoples R China
来源
关键词
insulators; corona current pulse; fuzzy logical reasoning; diagnosis method;
D O I
10.4028/www.scientific.net/AMR.301-303.895
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A series of experiments on the corona current pulse appearing on insulators under various contamination conditions with AC voltage of different amplitude are described. The corona current pulses were found to follow the Gaussian distribution and can be used to distinguish the faulty insulators from normal insulator strings in transmission line. The probability formulas about the corona current pulses have been studied in detail. They can be used as a kind of criterions to detect the faulty insulators. With several established fuzzy membership functions of humidity and contamination through data from experiments, it is proved that the insulation state could be estimated from the transmission line insulator strings by the fuzzy logical reasoning. This method has been verified in the laboratory by simulating work conditions of insulator strings on an 110kV transmission line and has the advantage of safety and convenience.
引用
收藏
页码:895 / +
页数:2
相关论文
共 50 条
  • [31] Research on the standardization scheme of transmission line insulator fitting strings based on integrated universal design
    Fang, Zhenggang
    Li, Yigang
    Liu, Rui
    Zhang, Jinfeng
    2024 3RD INTERNATIONAL CONFERENCE ON ENERGY AND ELECTRICAL POWER SYSTEMS, ICEEPS 2024, 2024, : 432 - 436
  • [32] Satellite Telemetry System for Pollution Detection on Insulator Strings of High-Voltage Transmission Lines
    de Lima, Ricardo A.
    Fontana, Eduardo
    Martins-Filho, Joaquim F.
    Prata, Thiago L.
    Cavalcanti, Gustavo O.
    Lima, Renato B.
    Oliveira, Sergio Campello
    Cavalcanti, Fernando J. M. M.
    2009 SBMO/IEEE MTT-S INTERNATIONAL MICROWAVE AND OPTOELECTRONICS CONFERENCE (IMOC 2009), 2009, : 564 - +
  • [33] Technology of Actual Wind Deviation Monitoring for Suspension Insulator Strings Based on Improved Edge Detection
    Yang, Luya
    Huang, Xinbo
    Zhang, Ye
    Nie, Tingting
    IEEE ACCESS, 2019, 7 : 170157 - 170167
  • [34] RESEARCH STRINGS
    不详
    LANCET, 1971, 2 (7731): : 963 - +
  • [35] TRANSIENT THERMAL MODEL FOR SEMICONDUCTIVE INSULATOR STRINGS
    RAU, NS
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, 94 (06): : 1919 - 1919
  • [36] A New Climbing Robot for Suspension Insulator Strings
    Fang Lijin
    Xu Xinlin
    Guo Xiaokun
    2016 4TH INTERNATIONAL CONFERENCE ON APPLIED ROBOTICS FOR THE POWER INDUSTRY (CARPI), 2016,
  • [37] Flashover performance of HVDC iced insulator strings
    Li, Peng
    Fan, Jianbin
    Li, Wufeng
    Su, Zhiyi
    Zhou, Jun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (06) : 1334 - 1338
  • [38] BEHAVIOR OF LONG INSULATOR STRINGS IN DRY CONDITIONS
    HUTZLER, B
    RIU, JP
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (03): : 982 - 991
  • [39] A Simulation Research on RF Detection Method for Polymeric Insulator
    Zhao, Huiguang
    Ma, Zhifeng
    Wang, Haiming
    Qu, Fang
    Wang, Xinming
    Wu, Runqi
    Zhu, Xiangqian
    Yin, Jungang
    2019 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM - FALL (PIERS - FALL), 2019, : 2255 - 2259
  • [40] Faulty Insulator Diagnosis for UAV Videos based on Repetitiveness Feature
    Lin, Lan
    Li, Bingfeng
    Wang, Ling
    Cong, Yang
    Tang, Yandong
    APPLIED MATERIALS AND TECHNOLOGIES FOR MODERN MANUFACTURING, PTS 1-4, 2013, 423-426 : 2536 - +