Research On The Detection Of Faulty Insulator Strings

被引:1
|
作者
Nie Yi-xiong [1 ]
Peng Xian-gang [1 ]
Xu Xiao-ning [2 ]
机构
[1] Guangdong Univ Tech, Fac Automat, Guangzhou 510006, Guangdong, Peoples R China
[2] Guangzhou Univ, Coll Civil Engn, Guangzhou 510006, Guangdong, Peoples R China
来源
关键词
insulators; corona current pulse; fuzzy logical reasoning; diagnosis method;
D O I
10.4028/www.scientific.net/AMR.301-303.895
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A series of experiments on the corona current pulse appearing on insulators under various contamination conditions with AC voltage of different amplitude are described. The corona current pulses were found to follow the Gaussian distribution and can be used to distinguish the faulty insulators from normal insulator strings in transmission line. The probability formulas about the corona current pulses have been studied in detail. They can be used as a kind of criterions to detect the faulty insulators. With several established fuzzy membership functions of humidity and contamination through data from experiments, it is proved that the insulation state could be estimated from the transmission line insulator strings by the fuzzy logical reasoning. This method has been verified in the laboratory by simulating work conditions of insulator strings on an 110kV transmission line and has the advantage of safety and convenience.
引用
收藏
页码:895 / +
页数:2
相关论文
共 50 条
  • [21] Novel sensor system for leakage current detection on insulator strings of overhead transmission lines
    Fontana, Eduardo
    Oliveira, S. Campello
    Cavalcanti, F. J. M. M.
    Lima, R. Bandeira
    Martins-Filho, J. F.
    Meneses-Pacheco, E.
    2006 IEEE/PES Power Systems Conference and Exposition. Vols 1-5, 2006, : 2255 - 2255
  • [22] Windage Yaw Angle Detection of Suspension Insulator Strings Based on Edge Feature Matching
    Lu, Hai Jun
    Lv, Yu Xiang
    Ma, Wei Qing
    Zhao, Xiao Long
    Zheng, Xue Lian
    INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS, PTS 1-4, 2013, 241-244 : 98 - +
  • [23] Optical Detection of Partial Discharges on Insulator Strings of High-Voltage Transmission Lines
    Oliveira, Sergio Campello
    Fontana, Eduardo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (07) : 2328 - 2334
  • [24] Novel sensor system for leakage current detection on insulator strings of overhead transmission lines
    Fontana, Eduardo
    Oliveira, Sergio Campello
    Cavalcanti, Fernando Jose do Monte de Melo
    Lima, Renato Bandeira
    Martins-Filho, Joaquim F.
    Meneses-Pacheco, Elio
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (04) : 2064 - 2070
  • [25] Research on Insulator Detection by Nuclear Magnetic Resonance
    Zhang, Laifu
    Li, Xiaonan
    Liu, Guodiang
    RESEARCH IN MATERIALS AND MANUFACTURING TECHNOLOGIES, PTS 1-3, 2014, 835-836 : 180 - +
  • [26] Research on Ultraviolet Detection of Insulator Corona Discharge
    Liu, Shibo
    Huang, Dagui
    Zhang, Yongjie
    Zou, Xiang
    Liu, Yulu
    Huang, Siyuan
    Zhang, Lieping
    2014 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2014), 2014, : 1347 - 1352
  • [27] Composite Insulator Charged Detection Technology Research
    Gao, Yang
    Xu, Aoran
    Wu, Jianjun
    Qu, Chunyu
    Wang, Yupeng
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON MATERIAL, MECHANICAL AND MANUFACTURING ENGINEERING, 2015, 27 : 1258 - 1262
  • [28] Selection of numbers of insulator of pollution insulator strings for DC transmission line
    Wu, Guangya
    Cai, Wei
    Lu, Yanlong
    Xiao, Yong
    Zhao, Quanjiang
    Xue, Chunlin
    Gaodianya Jishu/High Voltage Engineering, 2001, 27 (06):
  • [29] Remote sensing system for faulty suspension insulator units
    Kikuchi, T
    Nakauchi, H
    Matsuoka, R
    Akizuki, M
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 1997, : 766 - 769
  • [30] Design of a novel portable faulty insulator detector controller
    Zhong, Yan-Bing
    Jiang, Xiu-Chen
    Xu, Qing-Long
    Hu, Yue