Delays in the detection of hypoxemia due to site of pulse oximetry probe placement

被引:29
|
作者
Hamber, EA [1 ]
Bailey, PL [1 ]
James, SW [1 ]
Wells, DT [1 ]
Lu, JK [1 ]
Pace, NL [1 ]
机构
[1] Univ Utah, Dept Anesthesiol, Salt Lake City, UT 84132 USA
关键词
hypoxemia; monitoring site; pulse oximetry;
D O I
10.1016/S0952-8180(99)00010-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objectives: To determine if there were anp differences in the time do detect hypoxemia related to the site of peripheral pulse oximetry (ear, hand and foot) during the rapid induction of hypoxemia in healthy volunteers. Design: Repeated-measures, longitudinal, observational study. Setting: Anesthesia clinical research area of the Department of Anesthesiology. Patients: 13 healthy volunteers, aged 18 to 44 years. Interventions: Nellcor N-200 (Nellcor, Inc., Pleasanton, CA) oximeter probes were placed at the ear, hand and foot. All units were turned on simultaneously with averaging times set for 5 seconds and signals sampled at 2 Hz. A computer-controlled anesthesia circuit was employed to induce mild hypercapnia and hyperoxia (end-tidal gas partial pressures: PETCO2 = 42 +/- 2 mmHg and PETO2 = 130 mmHg) for 5 minutes. PETO2 was then decreased to 45 +/- 2 mmHg over 60 seconds and held at that value for 5 minutes. Measurements and Main Results: The mean differences in time (sec) for pulse oximeters to detect hypoxemia (read less than 90%) between probe sites were determined and compared. The following mean differences in time (sec) for pulse oximeters to detect hypoxemia (read less than 90%) between probe sites were found: ear-hand = 6; hand-foot = 57; ear-foot = 63. Paired t-tests revealed statistically significant mean time delay differences of 51 seconds (p < 0.005) and 57 seconds (p < 0.005) for ear-hand versus hand-foot and for ear-hand versus ear-foot, respectively. Conclusions: In healthy volunteers, significant delays in the detection of acute hypoxemia by pulse oximetry occur when pulse oximeters are placed at the toe as compared with probes at either the ear or hand. (C) 1999 by Elsevier Science Inc.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 50 条
  • [41] Pulse oximetry is a poor predictor of hypoxemia in stable children with sickle cell disease
    Blaisdell, CJ
    Goodman, S
    Clark, K
    Casella, JF
    Loughlin, GM
    ARCHIVES OF PEDIATRICS & ADOLESCENT MEDICINE, 2000, 154 (09): : 900 - 903
  • [42] Pulse oximetry to detect hypoxemia during apnea: Comparison of finger and ear probes
    Lindholm, Peter
    Blogg, S. Lesley
    Gennser, Mikael
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2007, 78 (08): : 770 - 773
  • [43] THE USE OF PULSE OXIMETRY IN POSTOPERATIVE HYPOXEMIA IN PATIENTS AFTER PROPOFOL INDUCTION OF ANESTHESIA
    THOMSON, KD
    INOUE, T
    PAYNE, JP
    INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1989, 6 (01): : 7 - 10
  • [44] INTRAORAL PULSE OXIMETRY TO QUANTIFY SLEEP APNEA RELATED HYPOXEMIA: PROOF OF PRINCIPLE
    Vena, D.
    Esmaeili, N.
    Radmand, R.
    Mendelson, Y.
    Radmand, B.
    Sands, S.
    Azarbarzin, A.
    SLEEP MEDICINE, 2024, 115 : 361 - 361
  • [45] HYPOXEMIA IS REDUCED BY PULSE OXIMETRY MONITORING IN THE OPERATING-THEATER AND IN THE RECOVERY ROOM
    MOLLER, JT
    JENSEN, PF
    JOHANNESSEN, NW
    ESPERSEN, K
    BRITISH JOURNAL OF ANAESTHESIA, 1992, 68 (02) : 146 - 150
  • [46] The ability of pulse oximetry to screen for hypoxemia and hypercapnia in patients breathing room air
    Witting, MD
    Lueck, CH
    JOURNAL OF EMERGENCY MEDICINE, 2001, 20 (04): : 341 - 348
  • [47] Pulse Oximetry: Could Wrist and Ankle Be Alternative Placement Sites?
    Safar, Heba
    El-dash, Hanaa
    CLINICAL PEDIATRICS, 2015, 54 (14) : 1375 - 1379
  • [48] Pulse oximetry at two sensor placement sites in conscious foals
    Rossi, Heini Sofia
    Mykkanen, Anna Kristina
    Junnila, Jouni Juho Tapio
    Hyytiainen, Heli Katariina
    ACTA VETERINARIA SCANDINAVICA, 2025, 67 (01)
  • [49] Pulse oximetry probe adhesive disks: A potential for infant aspiration
    Reddy, SP
    Cook-Sather, SD
    ANESTHESIOLOGY, 1998, 89 (06) : 1603 - 1604
  • [50] Detection of pulpal circulation in vitro by pulse oximetry
    Noblett, WC
    Wilcox, LR
    Scamman, F
    Johnson, WT
    DiazArnold, A
    JOURNAL OF ENDODONTICS, 1996, 22 (01) : 1 - 5