Delays in the detection of hypoxemia due to site of pulse oximetry probe placement

被引:29
|
作者
Hamber, EA [1 ]
Bailey, PL [1 ]
James, SW [1 ]
Wells, DT [1 ]
Lu, JK [1 ]
Pace, NL [1 ]
机构
[1] Univ Utah, Dept Anesthesiol, Salt Lake City, UT 84132 USA
关键词
hypoxemia; monitoring site; pulse oximetry;
D O I
10.1016/S0952-8180(99)00010-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objectives: To determine if there were anp differences in the time do detect hypoxemia related to the site of peripheral pulse oximetry (ear, hand and foot) during the rapid induction of hypoxemia in healthy volunteers. Design: Repeated-measures, longitudinal, observational study. Setting: Anesthesia clinical research area of the Department of Anesthesiology. Patients: 13 healthy volunteers, aged 18 to 44 years. Interventions: Nellcor N-200 (Nellcor, Inc., Pleasanton, CA) oximeter probes were placed at the ear, hand and foot. All units were turned on simultaneously with averaging times set for 5 seconds and signals sampled at 2 Hz. A computer-controlled anesthesia circuit was employed to induce mild hypercapnia and hyperoxia (end-tidal gas partial pressures: PETCO2 = 42 +/- 2 mmHg and PETO2 = 130 mmHg) for 5 minutes. PETO2 was then decreased to 45 +/- 2 mmHg over 60 seconds and held at that value for 5 minutes. Measurements and Main Results: The mean differences in time (sec) for pulse oximeters to detect hypoxemia (read less than 90%) between probe sites were determined and compared. The following mean differences in time (sec) for pulse oximeters to detect hypoxemia (read less than 90%) between probe sites were found: ear-hand = 6; hand-foot = 57; ear-foot = 63. Paired t-tests revealed statistically significant mean time delay differences of 51 seconds (p < 0.005) and 57 seconds (p < 0.005) for ear-hand versus hand-foot and for ear-hand versus ear-foot, respectively. Conclusions: In healthy volunteers, significant delays in the detection of acute hypoxemia by pulse oximetry occur when pulse oximeters are placed at the toe as compared with probes at either the ear or hand. (C) 1999 by Elsevier Science Inc.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 50 条
  • [31] Pulse Oximetry Monitoring and Late Postoperative Hypoxemia on the General Care Floor
    John H. Eichhorn
    Journal of Clinical Monitoring and Computing, 1998, 14 : 49 - 55
  • [32] OCCULT HYPOXEMIA AND PULSE OXIMETRY PERFORMANCE ACROSS SKIN PIGMENTATION GROUPS
    Ajizian, Samuel
    McGonigle, Scott
    Dove, Jake
    Ting, Yu-Jung
    Sethi, Rakesh
    Milkes, David
    CRITICAL CARE MEDICINE, 2023, 51 (01) : 509 - 509
  • [33] THE PREVALENCE OF HYPOXEMIA DETECTED BY PULSE OXIMETRY DURING RECOVERY FROM ANESTHESIA
    MORRIS, RW
    BUSCHMAN, A
    WARREN, DL
    PHILIP, JH
    RAEMER, DB
    JOURNAL OF CLINICAL MONITORING, 1988, 4 (01): : 16 - 20
  • [34] Pulse oximetry: Utility in detecting arterial hypoxemia in subjects with cirrhosis.
    Abrams, GA
    Fallon, MB
    Nail, C
    McGuire, BM
    Van Leeuwen, DJ
    Eckhoff, DE
    Bynon, SJ
    Bloomer, JR
    HEPATOLOGY, 1999, 30 (04) : 435A - 435A
  • [35] PULSE OXIMETRY IN CONFIRMATION OF CORRECT TRACHEAL TUBE PLACEMENT
    SOSIS, MB
    SISAMIS, J
    ANESTHESIA AND ANALGESIA, 1990, 71 (03): : 309 - 310
  • [36] Disparities in Hypoxemia Detection by Pulse Oximetry Across Self-Identified Racial Groups and Associations With Clinical Outcomes*
    Henry, Nicole R.
    Hanson, Andrew C.
    Schulte, Phillip J.
    Warner, Nafisseh S.
    Manento, Megan N.
    Weister, Timothy J.
    Warner, Matthew A.
    CRITICAL CARE MEDICINE, 2022, 50 (02) : 204 - 211
  • [37] DETECTION OF PULSUS PARADOXUS BY PULSE OXIMETRY
    RYAN, CA
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1988, 142 (05): : 481 - 482
  • [38] REFLECTANCE PULSE OXIMETRY AT THE FOREHEAD IMPROVES BY PRESSURE ON THE PROBE
    DASSEL, ACM
    GRAAFF, R
    SIKKEMA, M
    MEIJER, A
    ZIJLSTRA, WG
    AARNOUDSE, JG
    JOURNAL OF CLINICAL MONITORING, 1995, 11 (04): : 237 - 244
  • [39] Phase delays in reflectance pulse oximetry: A Monte Carlo study
    Graaff, R
    Dassel, ACM
    Zijlstra, WG
    deMul, FFM
    Aarnoudse, JG
    OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING, PROCEEDINGS OF, 1996, 2628 : 361 - 368
  • [40] An Observational Study of the Risk Assessment of Severe Pneumonia for Prediction of Hypoxemia by Pulse Oximetry
    Singhal, Siddhant
    Kumar, Rekha
    Mahapatra, Chinmaya
    Jangid, Roshan
    Laxminath, T. Karthik
    JOURNAL OF PEDIATRICS REVIEW, 2021, 9 (04)