Disposable screen-printed sensors for the electrochemical detection of TNT and DNT

被引:53
|
作者
Caygill, J. Sarah [1 ]
Collyer, Stuart D. [2 ]
Holmes, Joanne L. [1 ]
Davis, Frank [1 ]
Higson, Seamus P. J. [1 ]
机构
[1] Cranfield Univ, Cranfield MK43 0AL, Beds, England
[2] Microarray Ltd, Manchester M60 1QD, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
EXPLOSIVE NITROAROMATIC COMPOUNDS; 2,4,6-TRINITROTOLUENE TNT; LIQUID-CHROMATOGRAPHY; ELECTRODES; SINGLE;
D O I
10.1039/c2an36351h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Due to the heightened level of national security currently prevalent due to the possibility of terrorist incidents, highly portable, miniaturised and sensitive monitoring devices for trace levels of injurious materials, such as explosives are now of the upmost importance. One method that offers a possible route for the development of a detection system for such species is via an electrochemical regime, coupled to the use of disposable sensor technology. Within this study, the use of carbon screen-printed sensors for the detection and analysis of the classical explosive trinitrotoluene (TNT) and the related dinitrotoluene (DNT) is described, with the eventual objective to develop an inexpensive, accurate and sensitive detection system for trace quantities of explosives in field settings. Commercially available screen-printed carbon sensors have been used as the base platform for this investigation and the electrochemistry of both TNT and DNT studied at these surfaces. Two reductive peaks and one oxidative peak were observed for both analytes. The best linear fits and sensitivities were obtained using the reductive peak at -0.72 V vs. Ag/AgCl. A linear range from 1 to 200 mu M could be obtained for TNT and DNT in pH 7.0 phosphate buffer with limits of detection as low as 0.4 mu M (TNT) and 0.7 mu M (DNT). A second system which utilised the addition of the enzyme, nitroreductase, and the coenzyme, NADPH, into the solution matrix prior to electrochemical interrogations with screen-printed carbon electrodes was found to increase the resulting signal magnitude at the oxidation peak at +0.3 V, improving the performance of the sensor at these values.
引用
收藏
页码:346 / 352
页数:7
相关论文
共 50 条
  • [21] A Simple Method to Tune Up Screen-Printed Carbon Electrodes Applicable to the Design of Disposable Electrochemical Sensors
    Su, Ya-Ling
    Tai, Chun-Yen
    Zen, Jyh-Myng
    [J]. ELECTROANALYSIS, 2013, 25 (11) : 2539 - 2546
  • [22] Screen-printed electrochemical immunosensors for PCB detection
    Laschi, S
    Fránek, M
    Mascini, M
    [J]. ELECTROANALYSIS, 2000, 12 (16) : 1293 - 1298
  • [23] Rapid hydrolysis and electrochemical detection of trace carbofuran at a disposable heated screen-printed carbon electrode
    Wei, Hang
    Sun, Jian-Jun
    Wang, Yan-Min
    Li, Xiao
    Chen, Guo-Nan
    [J]. ANALYST, 2008, 133 (11) : 1619 - 1624
  • [24] Disposable screen-printed electrodes for the immunochemical detection of polychlorinated biphenyls
    DelCarlo, M
    Lionti, I
    Taccini, M
    Cagnini, A
    Mascini, M
    [J]. ANALYTICA CHIMICA ACTA, 1997, 342 (2-3) : 189 - 197
  • [25] Azithromycin electrochemical detection using a molecularly imprinted polymer prepared on a disposable screen-printed electrode
    Rebelo, Patricia
    Pacheco, Joao G.
    Cordeiro, M. Natalia D. S.
    Melo, Andre
    Delerue-Matos, Cristina
    [J]. ANALYTICAL METHODS, 2020, 12 (11) : 1486 - 1494
  • [26] Disposable Screen Printed Electrochemical Sensors: Tools for Environmental Monitoring
    Hayat, Akhtar
    Marty, Jean Louis
    [J]. SENSORS, 2014, 14 (06): : 10432 - 10453
  • [27] A disposable electrochemical immunosensor based on carbon screen-printed electrodes for the detection of prostate specific antigen
    Yan, Mei
    Zang, Dejin
    Ge, Shenguang
    Ge, Lei
    Yu, Jinghua
    [J]. BIOSENSORS & BIOELECTRONICS, 2012, 38 (01): : 355 - 361
  • [28] Screen-Printed Sensors Modified with Nafion and Mesoporous Carbon for Electrochemical Detection of Lead in Blood
    Boselli, Elena
    Wu, Zhizhen
    Haynes, Erin N.
    Papautsky, Ian
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (02)
  • [29] Flexible Screen-Printed Electrochemical Sensors Functionalized with Electrodeposited Copper for Nitrate Detection in Water
    Inam, A. K. M. S.
    Angeli, Martina A. Costa
    Shkodra, Bajramshahe
    Douaki, Ali
    Avancini, Enrico
    Magagnin, Luca
    Petti, Luisa
    Lugli, Paolo
    [J]. ACS OMEGA, 2021, 6 (49): : 33523 - 33532
  • [30] SCREEN-PRINTED VOLTAMMETRIC AND AMPEROMETRIC ELECTROCHEMICAL SENSORS FOR DECENTRALIZED TESTING
    HART, JP
    WRING, SA
    [J]. ELECTROANALYSIS, 1994, 6 (08) : 617 - 624