Improvement and standardization of disinfection in hospital theatre with ultraviolet-C technology

被引:11
|
作者
Bosco, R. [1 ]
Cevenini, G. [2 ]
Gambelli, S. [3 ]
Nante, N. [4 ]
Messina, G. [4 ,5 ]
机构
[1] Univ Siena, Post Grad Sch Publ Hlth, Dept Mol & Dev Med, Siena, Italy
[2] Univ Siena, Dept Med Biotechnol, Siena, Italy
[3] Rugani Hosp Monteriggioni, Siena, Italy
[4] Univ Siena, Dept Mol & Dev Med, Siena, Italy
[5] Via Aldo Moro 2, I-53100 Siena, Italy
关键词
UVC; Hospital disinfection; Infection prevention; OPERATING-ROOM; LIGHT; DECONTAMINATION; INFECTION; UV;
D O I
10.1016/j.jhin.2022.07.006
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The level of disinfection between operating sessions is important to prevent cross-contamination risk in operating theatres. Aim: To assess the difference in microbial contamination between different disinfection levels, before (T0) and after (T1) application of a UVC device (UVC-D). Methods: A cross-sectional study was conducted between December 2019 and August 2020 in a clinic. Three disinfection levels - no disinfection after surgery, after in-between cleaning, and after terminal cleaning - were compared to assess the reduction of microbial presence at T0 and T1 according to the use of UVC-D for 3-5 min per bedside. A total of 260 Petri dishes, divided into a preliminary phase followed by a probabilistic model-driven experiment, were used in three operating theatres, and colony-forming units (cfu) were counted. The Mann-Whitney test was performed in the preliminary phase to establish UVC exposure time. Using the probabilistic model, descriptive statistics and percentage and log10 reduction were calculated. The multivariate analysis of variance (MANOVA) for repeated measures was performed to verify the 95% statistical difference between T0 and T1, combined with the disinfection levels and different operating theatres. Findings: The Mann-Whitney test showed no cfu difference between 3 and 5 min of UVC exposure time; the MANOVA test showed no significant difference between disinfection levels in T0 - T1 cfu reduction with a mean cfu reduction of 72% (95% confidence interval: 61.7-84.9) regardless of the disinfection level applied previously. Conclusion: UVC-D has improved environmental disinfection in all initial conditions. Together with the classic sanitizing procedures already present, it improves and standardizes the level of environmental hygiene. (c) 2022 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:19 / 25
页数:7
相关论文
共 50 条
  • [1] Clinical, operational, and financial impact of an ultraviolet-C terminal disinfection intervention at a community hospital
    Raggi, Robert
    Archulet, Kenneth
    Haag, Cody W.
    Tang, Weiming
    AMERICAN JOURNAL OF INFECTION CONTROL, 2018, 46 (11) : 1224 - 1229
  • [2] Safety and Effectiveness Assessment of Ultraviolet-C Disinfection in Aircraft Cabins
    Belland, Kris
    Garcia, Diego
    DeJohn, Charles
    Allen, Gary R.
    Mills, William D.
    Glaudel, Stephen P.
    AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2024, 95 (03) : 147 - 157
  • [3] Shining a light on ultraviolet-C disinfection: No golden promises for infection prevention
    de Kraker, Marlieke Elizabeth Adriana
    Harbarth, Stephan
    Dancer, Stephanie J.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2018, 46 (12) : 1422 - 1423
  • [4] Assessment of the effectiveness of ultraviolet-C disinfection on transmission of hospital-acquired pathogens from prior room occupants
    Hodges, Jacob C.
    Bilderback, Andrew L.
    Bridge, Christine M.
    Wagester, Suzanne
    Colaianne, Bonnie V.
    Babiker, Ahmed
    Minnier, Tami
    Zapf, Rachel L.
    Kip, Paula L.
    Snyder, Graham M.
    ANTIMICROBIAL STEWARDSHIP & HEALTHCARE EPIDEMIOLOGY, 2022, 2 (01): : S17 - S26
  • [5] Effectiveness of an ultraviolet-C disinfection system for reduction of healthcare-associated pathogens
    Yang, Jui-Hsuan
    Wu, Un-In
    Tai, Huei-Min
    Sheng, Wang-Huei
    JOURNAL OF MICROBIOLOGY IMMUNOLOGY AND INFECTION, 2019, 52 (03) : 487 - 493
  • [6] Radiation ultraviolet-c for bacterial disinfection (total and thermotolerant coliforms) in the water treatment
    Luis Jhordan, Rossel Bernedo
    Luis Alberth, Rossel Bernedo
    Felix Pompeyo, Ferro Mayhua
    Ana Lucia, Ferro Gonzales
    Ronal Reynaldo, Zapana Quispe
    REVISTA INVESTIGACIONES ALTOANDINAS-JOURNAL OF HIGH ANDEAN RESEARCH, 2020, 22 (01): : 68 - 77
  • [7] Design and Analysis of a Novel Ultraviolet-C Device for Surgical Face Mask Disinfection
    Armentano, Ilaria
    Barbanera, Marco
    Belloni, Elisa
    Crognale, Silvia
    Lelli, Davide
    Marconi, Marco
    Calabro, Giuseppe
    ACS OMEGA, 2022, : 34117 - 34126
  • [8] Effectiveness of ultraviolet-C vs aerosolized hydrogen peroxide in ICU terminal disinfection
    Kelly, S.
    Schnugh, D.
    Thomas, T.
    JOURNAL OF HOSPITAL INFECTION, 2022, 121 : 114 - 119
  • [9] Effectiveness of an ultraviolet-C disinfection system for reduction of multidrug-resistant pathogens
    Yang, Jui-Hsuan
    Wu, Un-In
    Tai, Huei-Min
    Sheng, Wang-Huei
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2017, 50 : S121 - S121
  • [10] Reduction of bacterial load with the addition of ultraviolet-C disinfection inside the hyperbaric chamber
    Browne, Katrina
    Wood, Danielle
    Clezy, Kate
    Lehm, Jan
    Walsh, William R.
    DIVING AND HYPERBARIC MEDICINE, 2020, 50 (04) : 332 - 337