Improvement and standardization of disinfection in hospital theatre with ultraviolet-C technology

被引:11
|
作者
Bosco, R. [1 ]
Cevenini, G. [2 ]
Gambelli, S. [3 ]
Nante, N. [4 ]
Messina, G. [4 ,5 ]
机构
[1] Univ Siena, Post Grad Sch Publ Hlth, Dept Mol & Dev Med, Siena, Italy
[2] Univ Siena, Dept Med Biotechnol, Siena, Italy
[3] Rugani Hosp Monteriggioni, Siena, Italy
[4] Univ Siena, Dept Mol & Dev Med, Siena, Italy
[5] Via Aldo Moro 2, I-53100 Siena, Italy
关键词
UVC; Hospital disinfection; Infection prevention; OPERATING-ROOM; LIGHT; DECONTAMINATION; INFECTION; UV;
D O I
10.1016/j.jhin.2022.07.006
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The level of disinfection between operating sessions is important to prevent cross-contamination risk in operating theatres. Aim: To assess the difference in microbial contamination between different disinfection levels, before (T0) and after (T1) application of a UVC device (UVC-D). Methods: A cross-sectional study was conducted between December 2019 and August 2020 in a clinic. Three disinfection levels - no disinfection after surgery, after in-between cleaning, and after terminal cleaning - were compared to assess the reduction of microbial presence at T0 and T1 according to the use of UVC-D for 3-5 min per bedside. A total of 260 Petri dishes, divided into a preliminary phase followed by a probabilistic model-driven experiment, were used in three operating theatres, and colony-forming units (cfu) were counted. The Mann-Whitney test was performed in the preliminary phase to establish UVC exposure time. Using the probabilistic model, descriptive statistics and percentage and log10 reduction were calculated. The multivariate analysis of variance (MANOVA) for repeated measures was performed to verify the 95% statistical difference between T0 and T1, combined with the disinfection levels and different operating theatres. Findings: The Mann-Whitney test showed no cfu difference between 3 and 5 min of UVC exposure time; the MANOVA test showed no significant difference between disinfection levels in T0 - T1 cfu reduction with a mean cfu reduction of 72% (95% confidence interval: 61.7-84.9) regardless of the disinfection level applied previously. Conclusion: UVC-D has improved environmental disinfection in all initial conditions. Together with the classic sanitizing procedures already present, it improves and standardizes the level of environmental hygiene. (c) 2022 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:19 / 25
页数:7
相关论文
共 50 条
  • [31] Hospital surface disinfection using ultraviolet germicidal irradiation technology: A review
    Scott, Robert
    Joshi, Lovleen Tina
    McGinn, Conor
    HEALTHCARE TECHNOLOGY LETTERS, 2022, 9 (03) : 25 - 33
  • [32] Impact of an automated multiple emitter whole-room ultraviolet-C disinfection system on hospital acquired infections: A quasi-experimental study
    Steele, Molly
    Hurtado, Ryan R.
    Rychlik, Karen
    Bonebrake, Amanda
    Bovee, Maria C.
    O'Donnell, Anna
    Perryman, Joshua
    Kociolek, Larry K.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2021, 49 (09) : 1200 - 1203
  • [33] Evaluation of a novel ultraviolet-c irradiation locker for microbial sterilization of hospital garments
    Castellanos, Jim
    Preminger, Jonathan
    Steinkamp, Michelle
    Longman, Randy
    Pryor, Kane O.
    ANESTHESIA AND ANALGESIA, 2020, 130 : 656 - 657
  • [34] Application of GaN-based ultraviolet-C light emitting diodes - UV LEDs - for water disinfection
    Wuertele, M. A.
    Kolbe, T.
    Lipsz, M.
    Kuelberg, A.
    Weyers, M.
    Kneissl, M.
    Jekel, M.
    WATER RESEARCH, 2011, 45 (03) : 1481 - 1489
  • [35] Enhancing food safety: Employing ultraviolet-C light emitting diodes for water, leaf, and surface disinfection
    Marques, Ana Paula
    Santos, Carolina
    Serio, Joao
    Crespo, Maria Teresa Barreto
    Pereira, Vanessa Jorge
    INNOVATIVE FOOD SCIENCE & EMERGING TECHNOLOGIES, 2024, 98
  • [36] Disinfection potential of ozone, ultraviolet-C and their combination in wash water for the fresh-cut vegetable industry
    Selma, Maria V.
    Allende, Ana
    Lopez-Galvez, Francisco
    Conesa, Maria A.
    Gil, Maria I.
    FOOD MICROBIOLOGY, 2008, 25 (06) : 809 - 814
  • [37] Efficacy of Ultraviolet-C Devices for the Disinfection of Personal Protective Equipment Fabrics and N95 Respirators
    Chandran, Kumari Moothedath
    Ramamurthy, Praveen C.
    Kanjo, Kawkab
    Narayan, Rohan
    Menon, S. Raghu
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2021, 126
  • [38] Efficacy of ultraviolet-C devices for the disinfection of personal protective equipment fabrics and N95 respirators
    Chandran, Kumari Moothedath
    Ramamurthy, Praveen C.
    Kanjo, Kawkab
    Narayan, Rohan
    Menon, S. Raghu
    1600, National Institute of Standards and Technology (126):
  • [39] A model for choosing an automated ultraviolet-C disinfection system and building a case for the C-suite: Two case reports
    Spencer, Maureen
    Vignari, Michelle
    Bryce, Elizabeth
    Johnson, Helen Boehm
    Fauerbach, Loretta
    Graham, Denise
    AMERICAN JOURNAL OF INFECTION CONTROL, 2017, 45 (03) : 288 - 292
  • [40] Ameliorative and Disinfection Effects of Ultraviolet-C Radiation on Experimentally Induced and Infected Skin Wounds: A Mice Model Study
    Ozmen, Ozlem
    Sababoglu, Ezgi
    Ozyildiz, Zafer
    Milletsever, Adem
    Okuyucu, Gozde
    INTERNATIONAL JOURNAL OF LOWER EXTREMITY WOUNDS, 2024, 23 (01): : 116 - 123