Radiation ultraviolet-c for bacterial disinfection (total and thermotolerant coliforms) in the water treatment

被引:2
|
作者
Luis Jhordan, Rossel Bernedo [1 ]
Luis Alberth, Rossel Bernedo [1 ]
Felix Pompeyo, Ferro Mayhua [2 ]
Ana Lucia, Ferro Gonzales [3 ]
Ronal Reynaldo, Zapana Quispe [1 ]
机构
[1] Univ Privada San Carlos, Fac Ingn, Puno, Peru
[2] Minist Salud Peru, Salud Chucuito, Reg Salud Puno, Lima, Peru
[3] Estudios Econ FerScar SAC Puno, Puno, Peru
关键词
Exposure time; bacterial inactivation; Colony Forming Units; Membrane Filter; UV; INACTIVATION;
D O I
10.18271/ria.2020.537
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The study aimed to evaluate the presence of bacteria (total and thermotolerant coliforms) in the treatment of water using Class C Ultraviolet Radiation (UV-C), the research was carried out in the Quality Control Laboratory of the Treatment Plant of Potable Water of the EPS, EMSA Puno, because current regulations require that total and thermotolerant coliform readings in drinking water should be 0 CFU / 100 ml, with UV-C radiation being an alternative for the decrease in Chlorine use. For what was experimented with a dose of 0,00176 W/cm(2)/s of UV-C radiation with a dominant wavelength of 254 nm, the experimental water samples were subjected to 1, 2, 3, and 4 seconds of exposure to the mentioned radiation. For the determination of the bacterial presence in water (total and thermotolerant coliforms), the Membrane Filter methodology was chosen, the results obtained for the total coliform count were readings on average of 200, 165, 59 and 0 CFU/100 ml and for the count of thermotolerant coliforms average readings of 4, 3, 1 and 0 CFU/100 ml. Concluding that, for the total inactivation of the total coliforms and thermotolerant coliforms present in the water samples, a minimum time of 4 s of exposure to UV-C radiation was required.
引用
收藏
页码:68 / 77
页数:10
相关论文
共 50 条
  • [1] Bacterial disinfection and cell assessment post ultraviolet-C LED exposure for wound treatment
    Sheikh, Jahanzeb
    Swee, Tan Tian
    Saidin, Syafiqah
    Yahya, Azli Bin
    Malik, Sameen Ahmed
    Yin, Joyce Sia Sin
    Thye, Matthias Tiong Foh
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2021, 59 (05) : 1055 - 1063
  • [2] Bacterial disinfection and cell assessment post ultraviolet-C LED exposure for wound treatment
    Jahanzeb Sheikh
    Tan Tian Swee
    Syafiqah Saidin
    Azli Bin Yahya
    Sameen Ahmed Malik
    Joyce Sia Sin Yin
    Matthias Tiong Foh Thye
    Medical & Biological Engineering & Computing, 2021, 59 : 1055 - 1063
  • [3] Reduction of bacterial load with the addition of ultraviolet-C disinfection inside the hyperbaric chamber
    Browne, Katrina
    Wood, Danielle
    Clezy, Kate
    Lehm, Jan
    Walsh, William R.
    DIVING AND HYPERBARIC MEDICINE, 2020, 50 (04) : 332 - 337
  • [4] Effect of Ultraviolet-C Light-Emitting Diode Treatment on Disinfection of Norovirus in Processing Water for Reuse of Brine Water
    Yoon, So-Ra
    Ha, Sanghyun
    Park, Boyeon
    Yang, Ji-Su
    Dang, Yun-Mi
    Ha, Ji-Hyoung
    FRONTIERS IN MICROBIOLOGY, 2022, 13
  • [5] Bacterial Contamination of Lead Aprons in a High-Volume Cardiac Catheterization Laboratory and Disinfection Using an Automated Ultraviolet-C Radiation System
    Ang, Lawrence
    Almasoud, Abdullah
    Palakodeti, Samhita
    Mahmud, Ehtisham
    JOURNAL OF INVASIVE CARDIOLOGY, 2018, 30 (11): : 416 - 420
  • [6] Improvement and standardization of disinfection in hospital theatre with ultraviolet-C technology
    Bosco, R.
    Cevenini, G.
    Gambelli, S.
    Nante, N.
    Messina, G.
    JOURNAL OF HOSPITAL INFECTION, 2022, 128 : 19 - 25
  • [7] Safety and Effectiveness Assessment of Ultraviolet-C Disinfection in Aircraft Cabins
    Belland, Kris
    Garcia, Diego
    DeJohn, Charles
    Allen, Gary R.
    Mills, William D.
    Glaudel, Stephen P.
    AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2024, 95 (03) : 147 - 157
  • [8] Detectors for the measurement of intense ultraviolet-C radiation
    Heering, W
    METROLOGIA, 1996, 32 (06) : 593 - 596
  • [9] Self-cooling water disinfection reactor with ultraviolet-C light-emitting diodes
    Wang, Chien-Ping
    Chan, Lo-Chieh
    Liao, Jun-You
    ENVIRONMENTAL TECHNOLOGY, 2023, 44 (22) : 3405 - 3414
  • [10] The response of Cochliobolus sativus to ultraviolet-C radiation
    Arabi, MIE
    Jawhar, M
    JOURNAL OF PHYTOPATHOLOGY, 2001, 149 (09) : 521 - 525