Radiation ultraviolet-c for bacterial disinfection (total and thermotolerant coliforms) in the water treatment

被引:2
|
作者
Luis Jhordan, Rossel Bernedo [1 ]
Luis Alberth, Rossel Bernedo [1 ]
Felix Pompeyo, Ferro Mayhua [2 ]
Ana Lucia, Ferro Gonzales [3 ]
Ronal Reynaldo, Zapana Quispe [1 ]
机构
[1] Univ Privada San Carlos, Fac Ingn, Puno, Peru
[2] Minist Salud Peru, Salud Chucuito, Reg Salud Puno, Lima, Peru
[3] Estudios Econ FerScar SAC Puno, Puno, Peru
关键词
Exposure time; bacterial inactivation; Colony Forming Units; Membrane Filter; UV; INACTIVATION;
D O I
10.18271/ria.2020.537
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The study aimed to evaluate the presence of bacteria (total and thermotolerant coliforms) in the treatment of water using Class C Ultraviolet Radiation (UV-C), the research was carried out in the Quality Control Laboratory of the Treatment Plant of Potable Water of the EPS, EMSA Puno, because current regulations require that total and thermotolerant coliform readings in drinking water should be 0 CFU / 100 ml, with UV-C radiation being an alternative for the decrease in Chlorine use. For what was experimented with a dose of 0,00176 W/cm(2)/s of UV-C radiation with a dominant wavelength of 254 nm, the experimental water samples were subjected to 1, 2, 3, and 4 seconds of exposure to the mentioned radiation. For the determination of the bacterial presence in water (total and thermotolerant coliforms), the Membrane Filter methodology was chosen, the results obtained for the total coliform count were readings on average of 200, 165, 59 and 0 CFU/100 ml and for the count of thermotolerant coliforms average readings of 4, 3, 1 and 0 CFU/100 ml. Concluding that, for the total inactivation of the total coliforms and thermotolerant coliforms present in the water samples, a minimum time of 4 s of exposure to UV-C radiation was required.
引用
收藏
页码:68 / 77
页数:10
相关论文
共 50 条
  • [41] Performance and Degradation of Commercial Ultraviolet-C Light-Emitting Diodes for Disinfection Purposes
    Trivellin, Nicola
    Piva, Francesco
    Fiorimonte, Davide
    Buffolo, Matteo
    De Santi, Carlo
    Zanoni, Enrico
    Meneghesso, Gaudenzio
    Meneghini, Matteo
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2023, 220 (16):
  • [42] Investigation of Ultraviolet-C light-emitting diode for airborne disinfection in air duct
    Li, Hongying
    Shan, Xuechuan
    Ba, Te
    Liu, Yu Chan
    Kang, Chang-Wei
    Hing, Candice Au Ka
    Loganathan, Nitin
    Velayutham, Uvarajan M. M.
    PHYSICS OF FLUIDS, 2023, 35 (04)
  • [43] Clinical, operational, and financial impact of an ultraviolet-C terminal disinfection intervention at a community hospital
    Raggi, Robert
    Archulet, Kenneth
    Haag, Cody W.
    Tang, Weiming
    AMERICAN JOURNAL OF INFECTION CONTROL, 2018, 46 (11) : 1224 - 1229
  • [44] Perspectives and recommendations regarding standards for ultraviolet-C whole-room disinfection in healthcare
    Kreitenberg A.
    Martinello R.A.
    Journal of Research of the National Institute of Standards and Technology, 2021, 126
  • [45] Bactericidal efficacy of mobile ultraviolet-C disinfection devices in reducing contamination in biosafety laboratories
    Tao, Chunai
    Tang, Xiaolan
    Luo, Jiayi
    Zhang, Xinbi
    JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2023, 17 (11): : 1574 - 1580
  • [46] Perspectives and Recommendations Regarding Standards for Ultraviolet-C Whole-Room Disinfection in Healthcare
    Kreitenberg, Arthur
    Martinello, Richard A.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2021, 126
  • [47] Ultraviolet-C Light Evaluation as Adjunct Disinfection to Remove Multidrug-Resistant Organisms
    Rock, Clare
    Hsu, Yea-Jen
    Curless, Melanie S.
    Carroll, Karen C.
    Ross Howard, Tracy
    Carson, Kathryn A.
    Cummings, Stephanie
    Anderson, Michael
    Milstone, Aaron M.
    Maragakis, Lisa L.
    CLINICAL INFECTIOUS DISEASES, 2022, 75 (01) : 35 - 40
  • [48] ENUMERATION OF THERMOTOLERANT COLIFORMS IN WATER USING DEOXYCHOLATE AGAR AT 43-DEGREES-C
    HIRAISHI, A
    SAHEKI, K
    HORIE, S
    BULLETIN OF THE JAPANESE SOCIETY OF SCIENTIFIC FISHERIES, 1983, 49 (08): : 1297 - 1297
  • [49] Ultra-Wideband Positioning Sensor with Application to an Autonomous Ultraviolet-C Disinfection Vehicle
    Huang, Shih-Ping
    Neo, Jin-Feng
    Chen, Yu-Yao
    Chen, Chien-Bang
    Wu, Ting-Wei
    Peng, Zheng-An
    Tsai, Wei-Ting
    Liou, Chong-Yi
    Sheng, Wang-Huei
    Mao, Shau-Gang
    SENSORS, 2021, 21 (15)
  • [50] DISINFECTION OF SEA-WATER BY ULTRAVIOLET-RADIATION
    KELLY, CB
    AMERICAN JOURNAL OF PUBLIC HEALTH AND THE NATIONS HEALTH, 1961, 51 (11): : 1670 - &