FI-spectrophotometric determination of uranium after preconcentration on an anion exchange resin

被引:9
|
作者
Nisa, Qamar Un [1 ]
Ali, Akbar [2 ]
Khan, Muhammad Haleem [1 ]
机构
[1] Univ Azad Jammu & Kashmir AJK, Dept Chem, Muzaffarabad, Pakistan
[2] Pakistan Inst Nucl Sci & Technol, Div Chem, Islamabad, Pakistan
关键词
Uranium; Online preconcentration; Anion exchange resin; Spectrophotometry; Arsenazo-III; FLOW-INJECTION ANALYSIS; SYSTEM; SEPARATION; THORIUM; SAMPLES;
D O I
10.1007/s10967-012-2278-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An economical, fast, sensitive and selective method for the determination of uranium (VI) from sulfate media based on the flow injection on-line preconcentration in a minicolumn having amberlite IRA-402 (strong anion exchange) resin is described. Uranium (VI) was selectively adsorbed on the resin as uranyl trisulfate complex from aqueous solution of pH 2 in the minicolumn (2.56 mm i.d. and 7.5 cm in length) at a flow rate of 10 ml min(-1). The adsorbed uranyl trisulfate complex was eluted by HClO4 (0.1 mol l(-1), 6.5 ml min(-1)) and mixed with arsenazo-III (0.05 %, 6.5 ml min(-1)), and passed through the flow through cell of spectrophotometer where its absorbance was measured at 653 nm. Various parameters affecting adsorption and elution of the uranium complex were optimized. For data analyses peak absorbance was used. For 60 and 180 s preconcentration time, enrichment factors (EF) 20 and 40, sampling frequency (SF) 45 and 18 h(-1); and detection limits (DL) (3 sigma) 14.2 and 8.6 mu g l(-1) were obtained, respectively. To enhance the sensitivity of the system, two minicolumns (described above) were used for simultaneous preconcentration and elution purpose. For 60 and 180 s preconcentration time, EF 30 and 50, SF 42 and 17 h(-1) and DL (3 sigma) 4.4 and 3.44 mu g l(-1) were obtained, respectively. The effect of various anions and cations was studied for single column manifold. High selectivity of this method was observed. All the anions and cations studied did not interfere up to 330 times higher mass ratio to 300 mu g l(-1) U (VI) except Th(IV) which was tolerated up to 133 times by the addition of washing step in the manifold. The method based on single column manifold was applied on the spiked tap water, biological sample CRM (IAEA-V4) and synthetic leach liquor solution and good recovery was obtained. The method based on dual column manifold was validated on lake sediment SL-1 (CRM) and the results obtained were in good agreement at 95 % confidence level with the given value.
引用
收藏
页码:2203 / 2214
页数:12
相关论文
共 50 条
  • [41] On-line spectrophotometric determination of scandium after preconcentration on XAD-4 resin impregnated with nalidixic acid
    Shabnam Shahida
    Akbar Ali
    Muhammad Haleem Khan
    Journal of the Iranian Chemical Society, 2013, 10 : 461 - 470
  • [42] DETERMINATION OF THE TETRATHIONATE CONTENT OF AN ANION-EXCHANGE RESIN
    NOVAK, G
    ERDELYI, M
    VIGVARI, M
    JOURNAL OF CHROMATOGRAPHY, 1980, 201 (NOV): : 313 - 315
  • [43] On-line spectrophotometric determination of scandium after preconcentration on XAD-4 resin impregnated with nalidixic acid
    Shahida, Shabnam
    Ali, Akbar
    Khan, Muhammad Haleem
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2013, 10 (03) : 461 - 470
  • [44] SPECTROPHOTOMETRIC DETERMINATION OF TRACES OF NITRITE BY CONCENTRATION OF AZO DYE ON AN ANION-EXCHANGE RESIN - APPLICATION TO SEA WATERS
    WADA, E
    HATTORI, A
    ANALYTICA CHIMICA ACTA, 1971, 56 (02) : 233 - &
  • [45] DETERMINATION OF TOTAL DISSOLVED PHOSPHORUS IN NATURAL-WATER BY GRAPHITE-FURNACE AAS AFTER PRECONCENTRATION WITH MOLYBDATE FORM ANION-EXCHANGE RESIN
    KUBOTA, T
    OKUTANI, T
    BUNSEKI KAGAKU, 1990, 39 (09) : 507 - 512
  • [46] Novel extractant impregnated resin for preconcentration and determination of uranium from environmental samples
    Tetgure, Sandesh R.
    Choudhary, Bharat C.
    Garole, Dipak J.
    Borse, Amulrao U.
    Sawant, Arun D.
    Prasad, Surendra
    MICROCHEMICAL JOURNAL, 2017, 130 : 442 - 451
  • [47] Flow injection on-line determination of uranium after preconcentration on XAD-4 resin impregnated with dibenzoylmethane
    Shahida, Shabnam
    Ali, Akbar
    Khan, Muhammad Haleem
    Saeed, Muhammad Mufazzal
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 289 (03) : 929 - 938
  • [48] Flow injection on-line determination of uranium after preconcentration on XAD-4 resin impregnated with dibenzoylmethane
    Shabnam Shahida
    Akbar Ali
    Muhammad Haleem Khan
    Muhammad Mufazzal Saeed
    Journal of Radioanalytical and Nuclear Chemistry, 2011, 289 : 929 - 938
  • [49] Determination of trace uranium in epoxy resin for semiconductor devices by fluorescence spectrometry after anion exchange separation and thenoyltrifluoroacetone liquid-liquid extraction
    Mitsumata, H
    Kita, Y
    BUNSEKI KAGAKU, 2005, 54 (11) : 1101 - 1105
  • [50] DETERMINATION OF RADIUM IN WATER BY LIQUID SCINTILLATION-COUNTING AFTER PRECONCENTRATION WITH ION-EXCHANGE RESIN
    HIGUCHI, H
    UESUGI, M
    SATOH, K
    OHASHI, N
    NOGUCHI, M
    ANALYTICAL CHEMISTRY, 1984, 56 (04) : 761 - 763