FI-spectrophotometric determination of uranium after preconcentration on an anion exchange resin

被引:9
|
作者
Nisa, Qamar Un [1 ]
Ali, Akbar [2 ]
Khan, Muhammad Haleem [1 ]
机构
[1] Univ Azad Jammu & Kashmir AJK, Dept Chem, Muzaffarabad, Pakistan
[2] Pakistan Inst Nucl Sci & Technol, Div Chem, Islamabad, Pakistan
关键词
Uranium; Online preconcentration; Anion exchange resin; Spectrophotometry; Arsenazo-III; FLOW-INJECTION ANALYSIS; SYSTEM; SEPARATION; THORIUM; SAMPLES;
D O I
10.1007/s10967-012-2278-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An economical, fast, sensitive and selective method for the determination of uranium (VI) from sulfate media based on the flow injection on-line preconcentration in a minicolumn having amberlite IRA-402 (strong anion exchange) resin is described. Uranium (VI) was selectively adsorbed on the resin as uranyl trisulfate complex from aqueous solution of pH 2 in the minicolumn (2.56 mm i.d. and 7.5 cm in length) at a flow rate of 10 ml min(-1). The adsorbed uranyl trisulfate complex was eluted by HClO4 (0.1 mol l(-1), 6.5 ml min(-1)) and mixed with arsenazo-III (0.05 %, 6.5 ml min(-1)), and passed through the flow through cell of spectrophotometer where its absorbance was measured at 653 nm. Various parameters affecting adsorption and elution of the uranium complex were optimized. For data analyses peak absorbance was used. For 60 and 180 s preconcentration time, enrichment factors (EF) 20 and 40, sampling frequency (SF) 45 and 18 h(-1); and detection limits (DL) (3 sigma) 14.2 and 8.6 mu g l(-1) were obtained, respectively. To enhance the sensitivity of the system, two minicolumns (described above) were used for simultaneous preconcentration and elution purpose. For 60 and 180 s preconcentration time, EF 30 and 50, SF 42 and 17 h(-1) and DL (3 sigma) 4.4 and 3.44 mu g l(-1) were obtained, respectively. The effect of various anions and cations was studied for single column manifold. High selectivity of this method was observed. All the anions and cations studied did not interfere up to 330 times higher mass ratio to 300 mu g l(-1) U (VI) except Th(IV) which was tolerated up to 133 times by the addition of washing step in the manifold. The method based on single column manifold was applied on the spiked tap water, biological sample CRM (IAEA-V4) and synthetic leach liquor solution and good recovery was obtained. The method based on dual column manifold was validated on lake sediment SL-1 (CRM) and the results obtained were in good agreement at 95 % confidence level with the given value.
引用
收藏
页码:2203 / 2214
页数:12
相关论文
共 50 条
  • [32] Adsorption of uranium on amino functionalized acrylonitrile anion exchange resin
    Li, Junhan
    Liu, Weigang
    Zhang, Zimin
    Li, Haonan
    Jiang, Qifeng
    Wang, Yingcai
    Tang, Rongjing
    Xu, Bin
    Guo, Ruihan
    Su, Xuebin
    Hua, Rong
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (12) : 5771 - 5779
  • [33] ANION EXCHANGE SEPARATION AND SPECTROPHOTOMETRIC DETERMINATION OF MICROGRAM QUANTITIES OF RHODIUM IN PLUTONIUM-URANIUM-FISSIUM ALLOYS
    EVANS, HB
    HUGHES, JP
    BLOOMQUIST, CAA
    ANALYTICAL CHEMISTRY, 1962, 34 (13) : 1692 - &
  • [34] Sorption and binary exchange of nitrate, sulfate, and uranium on an anion-exchange resin
    Gu, BH
    Ku, YK
    Jardine, PM
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (11) : 3184 - 3188
  • [35] ANION-EXCHANGE PRECONCENTRATION AND DETERMINATION OF BISMUTH IN ENVIRONMENTAL MATERIALS
    KURODA, R
    OGUMA, K
    MORI, Y
    OKABE, H
    TAKIZAWA, T
    CHROMATOGRAPHIA, 1991, 32 (11-12) : 583 - 585
  • [36] Determination of selenium content in natural water by graphite furnace atomic absorption spectrometry after preconcentration with molybdate-form anion exchange resin
    Kubota, T
    Okutani, T
    ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) : 319 - 324
  • [37] Selective preconcentration of uranium on chitosan stearoyl thiourea prior to its spectrophotometric determination
    Orabi, Ahmed
    Atrees, Mohamed
    Salem, Hend
    SEPARATION SCIENCE AND TECHNOLOGY, 2018, 53 (14) : 2267 - 2283
  • [38] ANION EXCHANGE SEPARATION FOR DETERMINATION OF URANIUM IN COMPLEX SOLUTIONS
    VITA, OA
    WALKER, CR
    TRIVISON.CF
    SPARKS, RW
    ANALYTICAL CHEMISTRY, 1970, 42 (04) : 465 - &
  • [39] Anion-exchange separation of interfering iron from liquid samples for accurate determination of uranium by spectrophotometric method
    Aziz, Abdul
    Sajjad, Muhammad
    Mohammad, Bashir
    DESALINATION AND WATER TREATMENT, 2017, 58 : 449 - 453
  • [40] DETERMINATION OF URANIUM AND THORIUM AFTER COMPLETE SAMPLE DECOMPOSITION AND ANION-EXCHANGE SEPARATION
    HOPKINS, DM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1978, 176 (SEP): : 41 - 41