Positron Range Correction in PET Using an Alternating EM Algorithm

被引:0
|
作者
Agbeko, Norbert N. [1 ]
Cheng, Ju-Chieh [2 ]
Laforest, Richard [2 ]
O'Sullivan, Joseph A. [1 ]
机构
[1] Washington Univ, Elect & Syst Engn Dept, St Louis, MO 63108 USA
[2] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO 63108 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In Positron Emission Tomography (PET), positrons travel a short distance before annihilating with an electron resulting in blurred reconstructed imaged because of the difference between the positions of the emitted positrons and their annihilation points. For radionuclides which have a long mean positron range, this results in a significant loss in spatial resolution. This blurring occurs in the image space and is independent of the tomographic imaging process. In this paper we propose a reconstruction algorithm that models the PET imaging problem as a two step process positron emission followed by annihilations which are detected by the imaging system. Within the first step of this approach, the standard EM algorithm for PET is viewed as reconstructing an annihilation distribution rather than the actual activity distribution. Second, the annihilation distribution is then viewed as a blurred version of the activity distribution which can be recovered by image deconvolution with a density dependant positron range kernel. Our proposed algorithm is expressed as an alternating maximization algorithm that maximizes the likelihood of the annihilation and activity distributions given the data.
引用
收藏
页码:2875 / 2878
页数:4
相关论文
共 50 条
  • [1] A Study on PET Image Quality Using Both Strong Magnetic Fields and a ML-EM Positron Range Correction Algorithm
    Burdette, D.
    Albani, D.
    Chesi, E.
    Clinthorne, N. H.
    Cochran, E.
    Honscheid, K.
    Huh, S. S.
    Kagan, H.
    Knopp, M.
    Lacasta, C.
    Mikuz, M.
    Schmalbrock, P.
    Studen, A.
    Weihammer, P.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3646 - +
  • [2] Positron-Range Correction for an On-Chip PET Scanner using Deep Learning
    Clement, C.
    Birindelli, G.
    Pagano, F.
    Pizzichemi, M.
    Julio, M. Kruithof-De
    Ziegler, S.
    Rominger, A.
    Auffray, E.
    Shi, K.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S162 - S162
  • [3] Deep-Learning Based Positron Range Correction of PET Images
    Herraiz, Joaquin L.
    Bembibre, Adrian
    Lopez-Montes, Alejandro
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (01): : 1 - 13
  • [4] PET iterative reconstruction incorporating an efficient positron range correction method
    Bertolli, Ottavia
    Eleftheriou, Afroditi
    Cecchetti, Matteo
    Camarlinghi, Niccol
    Belcari, Nicola
    Tsoumpas, Charalampos
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 323 - 330
  • [5] Evaluation of the artifacts due to the positron range correction in PET image reconstruction using experimental phantom scans
    Cheng, Ju-Chieh
    Laforest, Richard
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [6] Feasibility of positron range correction in 82-Rubidium cardiac PET/CT
    Malte Jensen
    Simon Bentsen
    Andreas Clemmensen
    Jacob Kildevang Jensen
    Johanne Madsen
    Jonas Rossing
    Anna Laier
    Philip Hasbak
    Andreas Kjaer
    Rasmus Sejersten Ripa
    [J]. EJNMMI Physics, 9
  • [7] Feasibility of positron range correction in 82-Rubidium cardiac PET/CT
    Jensen, Malte
    Bentsen, Simon
    Clemmensen, Andreas
    Jensen, Jacob Kildevang
    Madsen, Johanne
    Rossing, Jonas
    Laier, Anna
    Hasbak, Philip
    Kjaer, Andreas
    Ripa, Rasmus Sejersten
    [J]. EJNMMI PHYSICS, 2022, 9 (01)
  • [8] Experimental validation of gallium production and isotope-dependent positron range correction in PET
    Fraile, L. M.
    Herraiz, J. L.
    Udias, J. M.
    Cal-Gonzalez, J.
    Corzo, P. M. G.
    Espana, S.
    Herranz, E.
    Perez-Liva, M.
    Picado, E.
    Vicente, E.
    Munoz-Martin, A.
    Vaquero, J. J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 814 : 110 - 116
  • [9] Positron Range Correction for 82Rb myocardial PET: Validation in a healthy cohort
    Lassen, M.
    Kertesz, H.
    Rausch, I.
    Kjaer, A.
    Panin, V.
    Bharkhada, D.
    DeKemp, R.
    Beyer, T.
    Hasbak, P.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S200 - S201
  • [10] Fast 3D kernel computation method for positron range correction in PET
    Li, Chong
    Scheins, Juergen
    Tellmann, Lutz
    Issa, Ahlam
    Wei, Long
    Shah, N. Jon
    Lerche, Christoph
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (02):