Development and evaluation of a high performance micro-CT system for insect or small animal imaging

被引:0
|
作者
Gui, Jianbao [1 ,2 ]
Zou, Jing [1 ,2 ]
Rong, Junyan [1 ,2 ]
Hu, Zhanli [1 ,2 ]
Li, Yanming [1 ,2 ]
Xi, Dongxing [1 ,2 ]
Zheng, Hairong [1 ,2 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Inst Biomed & Hlth Engn, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen, Peoples R China
[2] Chinese Acad Sci, Key Lab Biomed Informat & Hlth Engn, Shenzhen, Peoples R China
关键词
micro-CT; small animal imaging; insect imaging; spatial resolution; cooled CCD; DIGITAL RADIOGRAPHY; COMPUTED-TOMOGRAPHY; DETECTOR;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A high performance micro-tomography (micro-CT) system for insect or small animal imaging has been developed. The system consists of an x-ray source with small focus spot and high brightness, a high precision rotation stage with an object chuck to achieve a cone-beam mode scan, and an x-ray imaging detector. The core of the system is a cooled x-ray imaging detector with high spatial resolution, high sensitivity and ultralow noise. Since imaging performance of the detector is mostly responsible for the resultant image quality and eventually determines the quality of a tomogram, we have evaluated the imaging characteristics of the detector in terms of modulation-transfer function (MTF), noise-power spectrum (NPS) and give some high quality x-ray digital radiation (DR) and 3D rendered CT images of some insects and a small fish.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Design an development of a high performance micro-CT system for small animal imaging
    Lage, E.
    Vaquero, J. J.
    Redondo, S.
    Abella, M.
    Tapias, G.
    Udias, A.
    Desco, M.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3549 - 3552
  • [2] Geometric Calibration of a Micro-CT System and Performance for Insect Imaging
    Hu, Zhanli
    Gui, Jianbao
    Zou, Jing
    Rong, Junyan
    Zhang, Qiyang
    Zheng, Hairong
    Xia, Dan
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (04): : 655 - 660
  • [3] Micro-CT in small animal and specimen imaging
    Holdsworth, David W.
    Thornton, Michael M.
    [J]. TRENDS IN BIOTECHNOLOGY, 2002, 20 (08) : S34 - S39
  • [4] Application of micro-CT in small animal imaging
    Schambach, Sebastian J.
    Bag, Simona
    Schilling, Lothar
    Groden, Christoph
    Brockmann, Marc A.
    [J]. METHODS, 2010, 50 (01) : 2 - 13
  • [5] A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging
    Lee, SC
    Kim, HK
    Chun, IK
    Cho, MH
    Lee, SY
    Cho, MH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (24): : 4173 - 4185
  • [6] Performance characteristics of the Inveon micro-CT scanner in small animal imaging
    Khalil, Magdy Mohamed
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (01):
  • [7] Performance evaluation of a micro-CT system for laboratory animal imaging with iterative reconstruction capabilities
    Muller, Florence M.
    Vanhove, Christian
    Vandeghinste, Bert
    Vandenberghe, Stefaan
    [J]. MEDICAL PHYSICS, 2022, 49 (05) : 3121 - 3133
  • [8] A micro-CT system for little animal imaging
    Zhong, AJ
    Ye, C
    Luo, QM
    [J]. PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, 2003, 5254 : 330 - 335
  • [9] A framework for optimizing micro-CT in dual-modality micro-CT/XFCT small-animal imaging system
    Vedantham, Srinivasan
    Shrestha, Suman
    Karellas, Andrew
    Cho, Sang Hyun
    [J]. RADIATION DETECTORS IN MEDICINE, INDUSTRY, AND NATIONAL SECURITY XVIII, 2017, 10393
  • [10] Ultrafast laser-based micro-CT system for small animal imaging
    Krol, A
    Kieffer, JC
    Nees, J
    Chen, L
    Toth, R
    Hou, B
    Kincaid, RE
    Coman, IL
    Lipson, ED
    Mourou, G
    [J]. MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 265 - 271