Validation of secondary fluorescence excitation in quantitative X-ray fluorescence analysis of thin alloy films

被引:6
|
作者
Waehlisch, Andre [1 ]
Streeck, Cornelia [1 ]
Hoenicke, Philipp [1 ]
Beckhoff, Burkhard [1 ]
机构
[1] Phys Tech Bundesanstalt, Abbestr 2-12, D-10587 Berlin, Germany
关键词
ELEMENTAL DISTRIBUTIONS; THICKNESS DETERMINATION; CALIBRATION; INTENSITIES; SPECTROMETRY; COATINGS; COPPER; BULK;
D O I
10.1039/d0ja00171f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
X-ray fluorescence (XRF) analysis is a widely applied technique for the quantitative analysis of thin films up to the mu m scale because of its non-destructive nature and because it is easily automated. When low uncertainties of the analytical results in the few percent range are required, the non-linear secondary fluorescence effect in multi-elemental samples may complicate an otherwise straightforward quantification, since it can easily exceed a relative contribution of 20%. The conventional solution, to rely on good performing reference samples, is hindered by their low availability, especially for thin film applications. To address this challenge, we demonstrate a flexible production method of multilayered, alloyed thin films with significant secondary fluorescence contributions. We use reference-free XRF analysis to validate the reliability of the physical model for secondary fluorescence, which includes a thorough uncertainty estimation. The investigated specimens are qualified as calibration samples for XRF or other quantitative analyses.
引用
收藏
页码:1664 / 1670
页数:7
相关论文
共 50 条
  • [31] Quantitative X-ray fluorescence characterization of BST films grown by MOCVD
    Kwon, HJ
    Jo, W
    Kim, HH
    Jeong, YW
    Lee, JS
    Yoon, HR
    Ban, IS
    Bogert, JR
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 1998, 32 : S1559 - S1561
  • [32] QUANTITATIVE X-RAY-FLUORESCENCE ANALYSIS OF BORON IN THIN-FILMS OF BOROPHOSPHOSILICATE GLASSES
    SCHUSTER, M
    MULLER, L
    MAUSER, KE
    STRAUB, R
    THIN SOLID FILMS, 1988, 157 (02) : 325 - 336
  • [33] Analytical approximation for calculating secondary fluorescence in X-ray fluorescence analysis of powdered materials
    Finkelshtein, AL
    Afonin, VP
    X-RAY SPECTROMETRY, 1996, 25 (05) : 210 - 214
  • [34] Secondary Fluorescence Enhancement in Confocal X-ray Microscopy Analysis
    Sokaras, Dimosthenis
    Karydas, Andreas-Germanos
    ANALYTICAL CHEMISTRY, 2009, 81 (12) : 4946 - 4954
  • [35] An x-ray fluorescence method for determining the average density of thin films
    Trushin, OS
    Bochkarev, VF
    Goryachev, AA
    Naumov, VV
    Lebedev, AA
    INDUSTRIAL LABORATORY, 2000, 66 (10): : 674 - 675
  • [36] Quantitative analysis of radioactive materials by X-ray fluorescence.
    Worley, CG
    Colletti, LP
    Havrilla, GJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : B152 - B152
  • [37] Quantitative Analysis of Complex Aluminum Electrolytes by X-Ray Fluorescence
    Tan, Qi
    Gao, Bingliang
    Gao, Pengde
    Fan, Chao
    Li, Haijun
    LUMINESCENCE, 2024, 39 (11)
  • [38] The influence of scattering processes in quantitative X-ray fluorescence analysis
    Bos, M
    Vrielink, JAM
    ANALYTICA CHIMICA ACTA, 2005, 545 (01) : 92 - 98
  • [39] BORAX FUSION TECHNIQUE FOR QUANTITATIVE X-RAY FLUORESCENCE ANALYSIS
    VANWILLI.JH
    KRUIDHOF, H
    DAHMEN, EAMF
    TALANTA, 1971, 18 (04) : 450 - &
  • [40] Systematization of problems in quantitative X-ray fluorescence analysis of rocks
    Borkhodoev, VY
    JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 54 (05) : 396 - 400