Validation of secondary fluorescence excitation in quantitative X-ray fluorescence analysis of thin alloy films

被引:6
|
作者
Waehlisch, Andre [1 ]
Streeck, Cornelia [1 ]
Hoenicke, Philipp [1 ]
Beckhoff, Burkhard [1 ]
机构
[1] Phys Tech Bundesanstalt, Abbestr 2-12, D-10587 Berlin, Germany
关键词
ELEMENTAL DISTRIBUTIONS; THICKNESS DETERMINATION; CALIBRATION; INTENSITIES; SPECTROMETRY; COATINGS; COPPER; BULK;
D O I
10.1039/d0ja00171f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
X-ray fluorescence (XRF) analysis is a widely applied technique for the quantitative analysis of thin films up to the mu m scale because of its non-destructive nature and because it is easily automated. When low uncertainties of the analytical results in the few percent range are required, the non-linear secondary fluorescence effect in multi-elemental samples may complicate an otherwise straightforward quantification, since it can easily exceed a relative contribution of 20%. The conventional solution, to rely on good performing reference samples, is hindered by their low availability, especially for thin film applications. To address this challenge, we demonstrate a flexible production method of multilayered, alloyed thin films with significant secondary fluorescence contributions. We use reference-free XRF analysis to validate the reliability of the physical model for secondary fluorescence, which includes a thorough uncertainty estimation. The investigated specimens are qualified as calibration samples for XRF or other quantitative analyses.
引用
收藏
页码:1664 / 1670
页数:7
相关论文
共 50 条
  • [21] Assessing the Impact of Secondary Fluorescence on X-Ray Microanalysis Results from Semiconductor Thin Films
    Hunter, Daniel A.
    Lavery, Samuel P.
    Edwards, Paul R.
    Martin, Robert W.
    MICROSCOPY AND MICROANALYSIS, 2022, 28 (05) : 1472 - 1483
  • [22] X-RAY-FLUORESCENCE ANALYSIS OF THIN-FILMS
    DARASHKEVICH, VR
    MALYUKOV, BA
    INDUSTRIAL LABORATORY, 1980, 46 (06): : 558 - 560
  • [23] COMPENSATION OF SELECTIVE EXCITATION OF X-RAY FLUORESCENCE
    LOSEV, NF
    PAVLINSKII, GV
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1969, 13 (10): : 1454 - +
  • [24] X-ray tube spectral measurement method for quantitative analysis of X-ray fluorescence analysis
    Sasaki, Nobuharu
    Okada, Kennji
    Kawai, Jun
    X-RAY SPECTROMETRY, 2010, 39 (05) : 328 - 331
  • [25] X-RAY FLUORESCENCE ANALYSIS
    BAREHAM, FR
    GIDLEY, JAF
    BUTLER, DH
    LINDSTROM
    POWELL, AR
    JOHNSON, W
    FOX, JGM
    COCKETT, GH
    JOURNAL OF THE INSTITUTE OF METALS, 1962, 90 (07): : 273 - &
  • [26] X-RAY FLUORESCENCE ANALYSIS
    OTTER, RJ
    MIKROCHIMICA ACTA, 1962, (05) : 983 - &
  • [27] Polychromatic and Microfocused X-ray Radiation for Traceable Quantitative X-ray Fluorescence Analysis
    Kayser, Yves
    Unterumsberger, Rainer
    Waehlisch, Andre
    Bzheumikhova, Karina
    Hoenicke, Philipp
    Zech, Claudia
    Beckhoff, Burkhard
    SPECTROSCOPY, 2021, 36 : 13 - 16
  • [28] X-RAY FLUORESCENCE ANALYSIS
    ROBERT, A
    BULLETIN DE LA SOCIETE FRANCAISE DE CERAMIQUE, 1968, (78): : 33 - &
  • [29] CALIBRATION TECHNIQUES FOR X-RAY FLUORESCENCE ANALYSIS OF THIN NICKEL-CHROMIUM FILMS
    SPIELBE.N
    ABOWITZ, G
    ANALYTICAL CHEMISTRY, 1966, 38 (02) : 200 - &
  • [30] A genetic algorithm for model-free X-ray fluorescence analysis of thin films
    Dane, AD
    Timmermans, PAM
    vanSprang, HA
    Buydens, LMC
    ANALYTICAL CHEMISTRY, 1996, 68 (14) : 2419 - 2425