Biomechanical Properties of the Cornea Measured With the Dynamic Scheimpflug Analyzer in Young Healthy Adults

被引:5
|
作者
Lee, Hun [1 ,2 ]
Kang, David Sung Yong [3 ]
Ha, Byoung Jin [3 ]
Choi, Jin Young [2 ]
Kim, Eung Kweon [2 ,4 ]
Seo, Kyoung Yul [2 ]
Kim, Ha Yan [5 ]
Kim, Tae-im [2 ]
机构
[1] Catholic Kwandong Univ, Coll Med, Int St Marys Hosp, Dept Ophthalmol, Inchon, South Korea
[2] Yonsei Univ, Coll Med, Inst Vis Res, Dept Ophthalmol, Seoul, South Korea
[3] Eyereum Eye Clin, Seoul, South Korea
[4] Yonsei Univ, Coll Med, Corneal Dystrophy Res Inst, Dept Ophthalmol, Seoul, South Korea
[5] Yonsei Univ, Coll Med, Biostat Collaborat Unit, Seoul, South Korea
关键词
corneal biomechanical property; dynamic Scheimpflug analyzer; young healthy adults; normal value database; OCULAR RESPONSE ANALYZER; IN-SITU KERATOMILEUSIS; INTRAOCULAR-PRESSURE; CROSS-LINKING; NORMAL EYES; PARAMETERS; KERATOCONUS; NONCONTACT;
D O I
10.1097/ICO.0000000000001001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the biomechanical properties of the cornea using the dynamic Scheimpflug analyzer in young healthy adults. Methods: This prospective cross-sectional population study included 944 eyes of 472 participants aged 20 to 40 years. Participants underwent ophthalmic investigations, including evaluation of biomechanical properties of the cornea using the dynamic Scheimpflug analyzer, manifest refraction, and measurements of keratometric values by autokeratometry, intraocular pressure (IOP) by noncontact tonometer, central corneal thickness (CCT) by ultrasound, and white-to-white distance by Scheimpflug tomography. Statistical analyses included determination of the reference interval with a bootstrapping method, linear quantile mixed-effects model, and Spearman correlation analysis between the corneal biomechanical parameters and other variables (age, manifest refraction spherical equivalent, CCT, IOP, white-to-white, and keratometric values). Results: The 90% CIs of all corneal biomechanical parameters demonstrated that the ranges of the 90% CIs for the reference data were almost identical with and without bootstrapping. Quantile regression to determine the fifth, 50th, and 95th percentiles of each corneal biomechanical parameter supported the findings from the nonparametric method with the 90% CIs. Correlation analysis showed significant correlations between the parameters and variables, but there was a relatively high Spearman correlation coefficient in the case of the correlations with the CCT and IOP. Conclusions: Using data from a large population of young healthy adults, we developed a database of normal values for multiple corneal biomechanical parameters obtained from the dynamic Scheimpflug analyzer. We conclude that the biomechanical properties of the cornea are influenced by the CCT and IOP.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [31] Dynamic Scheimpflug Ocular Biomechanical Parameters in Healthy and Medically Controlled Glaucoma Eyes
    Miki, Atsuya
    Yasukura, Yuichi
    Weinreb, Robert N.
    Yamada, Tomomi
    Koh, Shizuka
    Asai, Tomoko
    Ikuno, Yasushi
    Maeda, Naoyuki
    Nishida, Kohji
    JOURNAL OF GLAUCOMA, 2019, 28 (07) : 588 - 592
  • [32] A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers
    Lopez-Munoz, Alfredo
    Lopez-Castano, Isabel
    Torres-Parejo, Ursula
    Garcia-Romera, Marta-C.
    LIFE-BASEL, 2023, 13 (12):
  • [33] Biomechanical Responses of Healthy and Keratoconic Corneas Measured Using a Noncontact Scheimpflug-Based Tonometer
    Ali, Noor Q.
    Patel, Dipika V.
    McGhee, Charles N. J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (06) : 3651 - 3659
  • [34] Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes
    Shah, Sunil
    Laiquzzaman, Mohammed
    Bhojwani, Rajan
    Mantry, Sanjay
    Cunliffe, Ian
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) : 3026 - 3031
  • [35] Anterior segment parameters measured in young healthy cats using a rotating Scheimpflug camera
    Verneuil, Marc
    Marsot, Maud
    Ruchon, Charly
    VETERINARY OPHTHALMOLOGY, 2019, 22 (03) : 381 - 384
  • [36] Intraocular pressure measurements and corneal biomechanical properties using a dynamic Scheimpflug analyzer, after several keratoplasty techniques, versus normal eyes
    Hugo, J.
    Granget, E.
    Yin, G. Ho Wang
    Sampo, M.
    Hoffart, L.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2018, 41 (01): : 30 - 38
  • [37] Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients
    Sen, Emine
    Tutuncu, Yasemin
    Balikoglu-Yilmaz, Melike
    Elgin, Ufuk
    Berker, Dilek
    Ozturk, Faruk
    Guler, Serdar
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (08) : 1283 - 1288
  • [38] Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients
    Emine Sen
    Yasemin Tutuncu
    Melike Balikoglu-Yilmaz
    Ufuk Elgin
    Dilek Berker
    Faruk Ozturk
    Serdar Guler
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 1283 - 1288
  • [39] Dynamic ultra high speed Scheimpflug imaging for assessing corneal biomechanical properties
    Ambrosio, Renato, Jr.
    Ramos, Isaac
    Luz, Allan
    Faria, Fernando Correa
    Steinmueller, Andreas
    Krug, Matthias
    Belin, Michael W.
    Roberts, Cynthia Jane
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2013, 72 (02) : 99 - 102
  • [40] Dynamic Scheimpflug Analyzer (Corvis ST) for measurement of corneal biomechanical parameters. A praxis-related overview
    Herber, R.
    Terai, N.
    Pillunat, K. R.
    Raiskup, F.
    Pillunat, L. E.
    Spoerl, E.
    OPHTHALMOLOGE, 2018, 115 (08): : 635 - 643